2025/2026

UTAH Burglar Alarm License EXAM STUDY GUIDE 2026/2027 ACCURATE QUESTIONS WITH CORRECT DETAILED SOLUTIONS || 100% GUARANTEED PASS NEWEST VERSION 1. UL Standard for intrusion detectors - ANSWER 639 2. UL Standard for connectors and switches - ANSWER 634 3. When installing NC door contacts (open on alarm), the EOL resistor should be placed - ANSWER In series at device 4. When installing NO door contacts (short on alarm), the EOL resistor should be placed - ANSWER In parallel at device 5. A motion detector that uses a transmit frequency of 20 to 40 KHz is referred to as a: - ANSWER Ultrasonic detector 6. A motion detector that uses a transmit frequency of 10-20 GHz is referred to as a: - ANSWER Microwave detector 7. PIRs transmit on a frequency of 100-200 KHz. T or F - ANSWER False 8. T or F? PIRs are most sensitive to motion toward and away from the detector. - ANSWER False 9. T or F? Microwave detectors are most sensitive to motion toward and away from the detector. - ANSWER True 10. Biased magnetic contacts are used for - ANSWER High security applications 11. T or F? Microwave detectors can penetrate glass, wood paneling and Sheetrock. - ANSWER True 12. T or F? Dual technology motion detectors are used to reduce false alarms. - ANSWER True 13. T or F? PIRs utilize the Doppler shift principle to detect motion. - ANSWER False 14. Why are reed contacts are plated with rhodium or similar materials? - ANSWER To prevent welding 15. What is the National Electric Code? - ANSWER NFPA 70 16. What is the National Fire Alarm Code? - ANSWER NFPA 72 17. Which UL standard covers the installation of burglar alarms? - ANSWER 681 18. How long must an alarm business keep the training records for a system on file? - ANSWER 3 years from the training 19. A type of security system that restricts access to unauthorized users at certain times - ANSWER Access control 20. A type of alarm verification that requires a central station operator to place two phone calls before dispatching the proper authorities - ANSWER Enhanced call verification 21. Which type of ladder is most recommended for alarm technicians? - ANSWER Fiberglass 22. Is fall protection required by OSHA for employees climbing or working on portable ladders? - ANSWER No 23. How is a panic button most usually wired? - ANSWER Normally open 24. When do burglar alarm company licenses expire? - ANSWER March 31 of odd years 25. The transformer should only need what percent of its output to cover the needs of the alarm panel, devices, and battery charging? - ANSWER 80 percent 26. If you wire(2) 12 volt 7 amp batteries in series, what is the voltage/amperage? - ANSWER 24 volts 7 amps 27. If you wire (2) 12 volt 7 amp batteries in parallel, what is the voltage/amperage - ANSWER 12 volts 14 amps 28. A "man-sized opening" is at least how many square inches? - ANSWER 96 29. What is the proper way to test an alarm system's back up battery? - ANSWER Do a load test 30. What type of branch circuit should be used for a Fire Alarm Panel? - ANSWER Individual 31. What is the maximum distance you should run for IP cameras? - ANSWER 100 meters 32. What is the advantage of using single-ended beam smoke detectors vs. dual ended bean type? - ANSWER Easier and cheaper 33. If you have 4 devices wired in series together in a single zone, what happens to the amperage? - ANSWER Nothing 34. What is the minimum required spacing between Class 2 circuit wires and Class 3 circuit wires of no separating barriers? - ANSWER 2 inches 35. If a transformer's internal fuse is blown, what will the meter read when testing it? - ANSWER Open 36. Q1. Audible fire alarm signals used in household fire alarm systems shall conform to the performance requirements of Section(s) ______. (Select all that apply) - ANSWER The correct answers are: 18.4.3, 18.4.5.1, and 18.4.5.2 per NFPA 72 2016, Section 29.3.6. 37. Q2. If a household has multiple-station alarm devices: - ANSWER The correct answer is: When one device sounds an alarm, all multiple-station alarms sound per NFPA 72 2016, Section 29.5.2.1.1. 38. Q3. During a power outage, the secondary power source for a smoke or heat alarm must be capable of supplying power for 7 days in the normal condition. - ANSWER The correct answer is: True per NFPA 72 2016, Section 29.6.1(1). 39. Q4. Smoke alarms or smoke detectors are required at what locations? (Select all that apply) - ANSWER The correct answers are: In each sleeping room, outside each sleeping room, and on each level, per NFPA 72 2016, Section 29.5.1.1. 40. Q5. After operating the alarm device for 7 days during a commercial power loss, all secondary power supplies on household alarm devices must be capable of operating the alarm signal for at least _____ minutes. - ANSWER The correct answer is: 4 per NFPA 72 2016, Section 29.6.1(1). 41. Q6. The rechargeable battery for a secondary power supply for a smoke or heat alarm must be able to provide an audible trouble signal for at least _____. - ANSWER The correct answer is: 1 week (7 days) per NFPA 72 2016, Section 29.6.4(3)(e). 42. Q7. Audible alarms for a household system shall be at least _____ dBA in the sleeping areas. - ANSWER The correct answer is: 75 per NFPA 72 2016, Section 29.3.6 which refers us to Section 18.4.5.1 for sleeping area requirements. 43. Q8. Smoke alarms installed in one- and two-family dwellings must be replaced within _____. - ANSWER The correct answer is: 10 years from date of manufacture per NFPA 72 2016, Section 29.8.1.4(5)(b) and Section 14.4.7.1.

Show more Read less
Institution
UTAH Burglar Alarm License\\\\
Course
UTAH Burglar Alarm License\\\\

Content preview

UTAH Burglar Alarm License EXAM STUDY
GUIDE 2026/2027 ACCURATE QUESTIONS
WITH CORRECT DETAILED SOLUTIONS ||
100% GUARANTEED PASS
<NEWEST VERSION>


1. UL Standard for intrusion detectors - ANSWER ✔ 639

2. UL Standard for connectors and switches - ANSWER ✔ 634

3. When installing NC door contacts (open on alarm), the EOL resistor should
be placed - ANSWER ✔ In series at device

4. When installing NO door contacts (short on alarm), the EOL resistor should
be placed - ANSWER ✔ In parallel at device

5. A motion detector that uses a transmit frequency of 20 to 40 KHz is referred
to as a: - ANSWER ✔ Ultrasonic detector

6. A motion detector that uses a transmit frequency of 10-20 GHz is referred to
as a: - ANSWER ✔ Microwave detector

7. PIRs transmit on a frequency of 100-200 KHz. T or F - ANSWER ✔ False

8. T or F? PIRs are most sensitive to motion toward and away from the
detector. - ANSWER ✔ False

9. T or F? Microwave detectors are most sensitive to motion toward and away
from the detector. - ANSWER ✔ True

10.Biased magnetic contacts are used for - ANSWER ✔ High security
applications

,11.T or F? Microwave detectors can penetrate glass, wood paneling and
Sheetrock. - ANSWER ✔ True

12.T or F? Dual technology motion detectors are used to reduce false alarms. -
ANSWER ✔ True

13.T or F? PIRs utilize the Doppler shift principle to detect motion. - ANSWER
✔ False

14.Why are reed contacts are plated with rhodium or similar materials? -
ANSWER ✔ To prevent welding

15.What is the National Electric Code? - ANSWER ✔ NFPA 70

16.What is the National Fire Alarm Code? - ANSWER ✔ NFPA 72

17.Which UL standard covers the installation of burglar alarms? - ANSWER
✔ 681

18.How long must an alarm business keep the training records for a system on
file? - ANSWER ✔ 3 years from the training

19.A type of security system that restricts access to unauthorized users at
certain times - ANSWER ✔ Access control

20.A type of alarm verification that requires a central station operator to place
two phone calls before dispatching the proper authorities - ANSWER ✔
Enhanced call verification

21.Which type of ladder is most recommended for alarm technicians? -
ANSWER ✔ Fiberglass

22.Is fall protection required by OSHA for employees climbing or working on
portable ladders? - ANSWER ✔ No

23.How is a panic button most usually wired? - ANSWER ✔ Normally open

,24.When do burglar alarm company licenses expire? - ANSWER ✔ March 31
of odd years

25.The transformer should only need what percent of its output to cover the
needs of the alarm panel, devices, and battery charging? - ANSWER ✔ 80
percent

26.If you wire(2) 12 volt 7 amp batteries in series, what is the
voltage/amperage? - ANSWER ✔ 24 volts 7 amps

27.If you wire (2) 12 volt 7 amp batteries in parallel, what is the
voltage/amperage - ANSWER ✔ 12 volts 14 amps

28.A "man-sized opening" is at least how many square inches? - ANSWER ✔
96

29.What is the proper way to test an alarm system's back up battery? -
ANSWER ✔ Do a load test

30.What type of branch circuit should be used for a Fire Alarm Panel? -
ANSWER ✔ Individual

31.What is the maximum distance you should run for IP cameras? - ANSWER
✔ 100 meters

32.What is the advantage of using single-ended beam smoke detectors vs. dual-
ended bean type? - ANSWER ✔ Easier and cheaper

33.If you have 4 devices wired in series together in a single zone, what happens
to the amperage? - ANSWER ✔ Nothing

34.What is the minimum required spacing between Class 2 circuit wires and
Class 3 circuit wires of no separating barriers? - ANSWER ✔ 2 inches

35.If a transformer's internal fuse is blown, what will the meter read when
testing it? - ANSWER ✔ Open

, 36.Q1. Audible fire alarm signals used in household fire alarm systems shall
conform to the performance requirements of Section(s) ______. (Select all
that apply) - ANSWER ✔ The correct answers are: 18.4.3, 18.4.5.1, and
18.4.5.2 per NFPA 72 2016, Section 29.3.6.

37.Q2. If a household has multiple-station alarm devices: - ANSWER ✔ The
correct answer is: When one device sounds an alarm, all multiple-station
alarms sound per NFPA 72 2016, Section 29.5.2.1.1.

38.Q3. During a power outage, the secondary power source for a smoke or heat
alarm must be capable of supplying power for 7 days in the normal
condition. - ANSWER ✔ The correct answer is: True per NFPA 72 2016,
Section 29.6.1(1).

39.Q4. Smoke alarms or smoke detectors are required at what locations? (Select
all that apply) - ANSWER ✔ The correct answers are: In each sleeping
room, outside each sleeping room, and on each level, per NFPA 72 2016,
Section 29.5.1.1.

40.Q5. After operating the alarm device for 7 days during a commercial power
loss, all secondary power supplies on household alarm devices must be
capable of operating the alarm signal for at least _____ minutes. - ANSWER
✔ The correct answer is: 4 per NFPA 72 2016, Section 29.6.1(1).

41.Q6. The rechargeable battery for a secondary power supply for a smoke or
heat alarm must be able to provide an audible trouble signal for at least
_____. - ANSWER ✔ The correct answer is: 1 week (7 days) per NFPA 72
2016, Section 29.6.4(3)(e).

42.Q7. Audible alarms for a household system shall be at least _____ dBA in
the sleeping areas. - ANSWER ✔ The correct answer is: 75 per NFPA 72
2016, Section 29.3.6 which refers us to Section 18.4.5.1 for sleeping area
requirements.

43.Q8. Smoke alarms installed in one- and two-family dwellings must be
replaced within _____. - ANSWER ✔ The correct answer is: 10 years from
date of manufacture per NFPA 72 2016, Section 29.8.1.4(5)(b) and Section
14.4.7.1.

Written for

Institution
UTAH Burglar Alarm License\\\\
Course
UTAH Burglar Alarm License\\\\

Document information

Uploaded on
June 8, 2026
Number of pages
38
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$14.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProfBenjamin Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
701
Member since
1 year
Number of followers
17
Documents
3932
Last sold
6 hours ago
EXCELLENT ACHIEVERS LIBRARY

As a professional tutor, I provide exceptional assistance with homework, quizzes, and exams across various subjects, including Psychology, Nursing, Biological Sciences, Business, Engineering, Human Resource Management, and Mathematics. I am dedicated to offering high-quality support and ensuring that all work meets scholarly standards. To enhance the effectiveness of our services, I work with a team of experienced tutors to create comprehensive and effective revision materials. Together, we are committed to helping students achieve excellent grades through our collaborative efforts and expertise.

Read more Read less
3.8

143 reviews

5
62
4
20
3
37
2
12
1
12

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions