DAVIES SPI REVIEW REVIEW PACK 2026
FULLY SOLVED QUESTION SET

◉ During production of a sonogram you image blood, bile, soft
tissue, calcification and muscle. Which is the MOST attenuating?
Answer: Calcification


◉ Axial resolution is determined chiefly by?
Answer: Pulse duration


The shorter the pulse duration, the better the axial resolution


◉ The transfer of acoustic energy into heat is termed?
Answer: Absorption


◉ With A-mode, the strength of the echo signal is represented by:
Answer: The height of the spike


◉ What is the main advantage of using an intracavitary probe
compared to a standard transducer?

,Answer: Since the intracavitary probe is closer to the AOI, a higher
frequency transducer can be used, resulting in superior spatial
resolution.


◉ Absorption, scattering and attenuation all increases as
___________increases?
Answer: Frequency


◉ You notice that the image in the far field is less bright compared to
the near field. This is due to:
Answer: Sound attenuation


◉ The dark area (shadowing) underneath gallstones is primarily
due to:
Answer: Increased attenuation


◉ You are performing a sonographic exam with a wide-bandwidth
transducer. The advantage you obtain with this transducer
compared to a narrow-band transducer is:
Answer: Improved axial resolution


◉ Other names for axial resolution:
Answer: LARRD: longitudinal, axial, range, radial, and depth

, ◉ Dynamic receive focusing uses:
Answer: Time delays before echo signals from array elements are
combined


With dynamic receive focusing, the echoes that are received first are
held in delay circuitry until all of the
echoes from the same depth have been received. This results in
constructive interference of the waves and produces a higher
amplitude
and more focused signal.


◉ What describes the f-number?
Answer: Focal length divided by the aperture


The f-number is the ratio of the focal length to the size of the
aperture.


◉ For a non-focused transducer, the region between the transducer
element and the point at which the sound beam is narrowest is
called the:
Answer: Near zone length or fresnal zone

Información del documento

Subido en
8 de junio de 2026
Número de páginas
27
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
FocusFile7
3.9
(24)
Vendido
230
Seguidores
3
Artículos
59067
Última venta
4 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes