EPA 608 HVAC CERTIFICATION PRACTICE QUESTIONS AND ANSWERS COMPLETE EPA SECTION 608 TECHNICIAN CERTIFICATION STUDY GUIDE WITH VERIFIED QUESTIONS, DETAILED RATIONALES, CORE CERTIFICATION, TYPE I, TYPE II & TYPE III REFRIGERANT HANDLING, REFRIGERANT RECOVERY & RECYCLING, LEAK DETECTION, EPA REGULATIONS, OZONE PROTECTION, HVAC SAFETY & LICENSING EXAM PREP Question 1 What is the primary environmental concern associated with chlorofluorocarbon (CFC) refrigerants? A. They contribute to acid rain formation B. They cause immediate respiratory toxicity in humans C. They deplete stratospheric ozone through chlorine release D. They increase ground-level ozone pollution Correct Answer: C Rationale: CFCs release chlorine in the stratosphere, destroying ozone catalytically. ________________________________________ Question 2 Which refrigerant classification has zero ozone depletion potential (ODP)? A. CFC B. HCFC C. Halon D. HFC Correct Answer: D Rationale: HFCs contain no chlorine or bromine → zero ODP. ________________________________________ Question 3 Under EPA Section 608, what is the maximum allowable annual leak rate for commercial refrigeration systems containing more than 50 pounds of refrigerant? A. 10% B. 15% C. 25% D. 35% Correct Answer: D Rationale: Commercial refrigeration 50 lbs: 35% threshold. Other appliances 50 lbs: 15%. ________________________________________ Question 4 What does the term "recovery" mean in the context of EPA Section 608 refrigerant management? A. Processing refrigerant to meet ARI 700 virgin purity specifications B. Cleaning refrigerant on-site for immediate reuse in the same system C. Removing refrigerant from a system and storing it in an external container D. Destroying refrigerant through high-temperature incineration Correct Answer: C Rationale: Recovery = removal and external storage without testing/processing. ________________________________________ Question 5 Which color coding is standard for the compound (low-side) gauge on a refrigerant manifold gauge set? A. Red B. Yellow C. Blue D. Green Correct Answer: C Rationale: Blue = low side; Red = high side; Yellow = center service port. ________________________________________ Question 6 What is the required evacuation level for a high-pressure appliance containing less than 200 pounds of R-22 when using recovery equipment manufactured on or after November 15, 1993? A. 0 inches of Hg vacuum B. 4 inches of Hg vacuum C. 10 inches of Hg vacuum D. 15 inches of Hg vacuum Correct Answer: B Rationale: For 200 lbs of HCFC-22 → 4 inches Hg vacuum. ________________________________________ Question 7 Which of the following is NOT an acceptable method for leak detection in refrigeration systems? A. Electronic ultrasonic leak detector B. Halide torch producing a green flame C. Compressed oxygen pressurization with soap bubbles D. Fluorescent dye injection with UV light inspection Correct Answer: C Rationale: Compressed oxygen + oil = explosion hazard. Only nitrogen is acceptable. ________________________________________ Question 8 What is the primary purpose of a purge unit on a low-pressure centrifugal chiller? A. To recover refrigerant during system shutdown B. To remove non-condensable gases and moisture that leak into the system C. To compress refrigerant vapor for the condenser D. To regulate evaporator water flow rate Correct Answer: B Rationale: Purge units remove air/moisture that enters below-atmospheric chillers. ________________________________________ Question 9 According to ASHRAE Standard 34, how are refrigerants classified regarding toxicity? A. Class 1 (non-toxic) and Class 2 (toxic) B. Class A (lower toxicity) and Class B (higher toxicity) C. Class I (safe) and Class II (hazardous) D. Class X (acceptable) and Class Y (restricted) Correct Answer: B Rationale: Class A = lower toxicity; Class B = higher toxicity. ________________________________________ Question 10 What is the maximum fill capacity for a refrigerant recovery cylinder to allow for thermal expansion? A. 60% of water capacity B. 70% of water capacity C. 80% of water capacity D. 90% of water capacity Correct Answer: C Rationale: 80% maximum to allow vapor space for expansion. ________________________________________ Question 11 Which refrigerant is classified as a CFC? A. R-22 B. R-134a C. R-12 D. R-410A Correct Answer: C Rationale: R-12 is CFC; R-22 is HCFC; R-134a, R-410A are HFCs.

Content preview

EPA 608 HVAC CERTIFICATION PRACTICE QUESTIONS AND ANSWERS
COMPLETE EPA SECTION 608 TECHNICIAN CERTIFICATION STUDY
GUIDE WITH VERIFIED QUESTIONS, DETAILED RATIONALES, CORE
CERTIFICATION, TYPE I, TYPE II & TYPE III REFRIGERANT HANDLING,
REFRIGERANT RECOVERY & RECYCLING, LEAK DETECTION, EPA
REGULATIONS, OZONE PROTECTION, HVAC SAFETY & LICENSING EXAM
PREP




Question 1
What is the primary environmental concern associated with
chlorofluorocarbon (CFC) refrigerants?
A. They contribute to acid rain formation
B. They cause immediate respiratory toxicity in humans
C. They deplete stratospheric ozone through chlorine release
D. They increase ground-level ozone pollution
Correct Answer: C
Rationale: CFCs release chlorine in the stratosphere, destroying ozone
catalytically.


Question 2
Which refrigerant classification has zero ozone depletion potential
(ODP)?
A. CFC
B. HCFC

,C. Halon
D. HFC
Correct Answer: D
Rationale: HFCs contain no chlorine or bromine → zero ODP.


Question 3
Under EPA Section 608, what is the maximum allowable annual leak
rate for commercial refrigeration systems containing more than 50
pounds of refrigerant?
A. 10%
B. 15%
C. 25%
D. 35%
Correct Answer: D
Rationale: Commercial refrigeration >50 lbs: 35% threshold. Other
appliances >50 lbs: 15%.


Question 4
What does the term "recovery" mean in the context of EPA Section 608
refrigerant management?
A. Processing refrigerant to meet ARI 700 virgin purity specifications
B. Cleaning refrigerant on-site for immediate reuse in the same system
C. Removing refrigerant from a system and storing it in an external
container
D. Destroying refrigerant through high-temperature incineration

,Correct Answer: C
Rationale: Recovery = removal and external storage without
testing/processing.


Question 5
Which color coding is standard for the compound (low-side) gauge on a
refrigerant manifold gauge set?
A. Red
B. Yellow
C. Blue
D. Green
Correct Answer: C
Rationale: Blue = low side; Red = high side; Yellow = center service port.


Question 6
What is the required evacuation level for a high-pressure appliance
containing less than 200 pounds of R-22 when using recovery
equipment manufactured on or after November 15, 1993?
A. 0 inches of Hg vacuum
B. 4 inches of Hg vacuum
C. 10 inches of Hg vacuum
D. 15 inches of Hg vacuum
Correct Answer: B
Rationale: For <200 lbs of HCFC-22 → 4 inches Hg vacuum.

, Question 7
Which of the following is NOT an acceptable method for leak detection
in refrigeration systems?
A. Electronic ultrasonic leak detector
B. Halide torch producing a green flame
C. Compressed oxygen pressurization with soap bubbles
D. Fluorescent dye injection with UV light inspection
Correct Answer: C
Rationale: Compressed oxygen + oil = explosion hazard. Only nitrogen is
acceptable.


Question 8
What is the primary purpose of a purge unit on a low-pressure
centrifugal chiller?
A. To recover refrigerant during system shutdown
B. To remove non-condensable gases and moisture that leak into the
system
C. To compress refrigerant vapor for the condenser
D. To regulate evaporator water flow rate
Correct Answer: B
Rationale: Purge units remove air/moisture that enters below-
atmospheric chillers.


Question 9
According to ASHRAE Standard 34, how are refrigerants classified
regarding toxicity?

Document information

Uploaded on
June 2, 2026
Number of pages
111
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
maingirose
4.3
(4)
Sold
32
Followers
0
Items
2234
Last sold
21 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions