Header joist span - ANSWER-When the header joist span does not exceed 4 ft, the
header joist may be a single member of the same size as the floor joist.
Masonry chimney foundation thickness - ANSWER-Foundations for masonry chimneys
shall be constructed of concrete or solid masonry at least 9 in thick.
Notching of floor framing members - ANSWER-For floor framing, the tension side of
members of 2 in or greater in nominal thickness shall not be notched except at the end
of the members.
Concrete slab-on-grade minimum thickness - ANSWER-Concrete slab-on-grade floors
shall be a minimum of 4 1/2 in thick.
Hearth extension dimensions for fireplaces - ANSWER-On fireplace openings larger than
6 square feet, hearth extensions shall extend at least 20 in in front and at least 12 in
beyond each side of the fireplace opening.
Ceiling R-value in climate zone 6 - ANSWER-Ceiling R-values in climate zone 6 shall be
a minimum of R-49.
Designated climate zone for Dallas County, Texas - ANSWER-The designated climate
zone for Dallas County, Texas is 3A.
Bottom plate to stud fastening - ANSWER-Bottom plate to stud toe-nail fastening shall
use 4 8d common nails.
Nonabsorbent surface height for showers - ANSWER-Showers and bathtubs with
installed shower heads shall be finished with a nonabsorbent surface that shall extend
to a height of not less than 6 ft above the floor.
Insulation thermal resistance in wall cavities - ANSWER-Cavities within corners and
headers of frame wall shall be insulated by completely filling cavity with a material
having a thermal resistance of not less than R-3 per inch.

, Fire separation distance for exterior walls - ANSWER-Exterior walls with a fire separation
distance less than 5 ft shall have not less than one-hour fire-resistive rating with
exposure from both sides.
Load bearing wall - ANSWER-A wall supporting any vertical load in addition to its own
weight is a Load Bearing Wall.
Air space clearance for masonry chimneys - ANSWER-Any portion of a masonry
chimney located on the exterior of a building or within an exterior wall shall have a
minimum air space clearance to combustibles of 2 in.
Anchor bolt spacing - ANSWER-Anchor bolts shall be spaced a maximum of 6 ft on
center and no further than 12 in from each corner.
Authority to establish refund policy - ANSWER-The Building Official has the authority to
establish a refund policy in a building department.
Programmable thermostats cooling setpoint - ANSWER-Required programmable
thermostats for residential homes shall be programmed from the manufacturer to
maintain a cooling temperature setpoint of not less than 78 degrees Fahrenheit.
Permits for retaining walls - ANSWER-Permits are not required for retaining walls that
are not over 4 ft in height unless supporting a surcharge.
Smoke alarms locations - ANSWER-Smoke alarms shall be required near each cooking
location, in each sleeping room, in attics, and in concealed locations.
Fasteners for asphalt shingles - ANSWER-Asphalt shingles shall be secured to the roof
with not less than 4 fasteners per strip shingle.
Concrete forming system - ANSWER-A concrete forming system using stay-in-place
forms of rigid foam plastic insulation, a hybrid of cement and foam insulation, a hybrid of
cement and wood chips, or other insulating material for constructing cast-in-place
concrete walls is called Insulating concrete form.
Air space for stone veneer - ANSWER-Stone or masonry veneer with wood stud backing
with metal strand wire shall be separated from sheathing by an air space of a minimum
of 1 in but not more than 4 1/2 in.
Braced walls thickness - ANSWER-The construction of braced walls may be of gypsum
board with a minimum thickness of 1/2 in.
Factory-built chimneys standards - ANSWER-Factory-built chimneys shall be listed and
labeled in accordance with UL 103.
Handrails space - ANSWER-Handrails adjacent to a wall shall have a space of not less
than 1 1/2 in.
Weep holes diameter - ANSWER-Weep holes in masonry veneer shall not be less than
3/16 in in diameter.
Guards height for raised surfaces - ANSWER-Porches, balconies, ramps or raised floor
surfaces located more than 30 inches above the floor or grade below shall have guards
not less than 34 in in height.
Concrete wall splice length - ANSWER-A concrete wall using number 4 rebar with a yield
strength of 40,000 psi, must have a minimum splice length or tension development
length of 12 in.
Gypsum board installation spacing - ANSWER-Water-resistant gypsum board shall be
permitted to be installed perpendicularly on ceilings where the framing spacing does not
exceed 24 in on center for 1/2 inch thick gypsum board.

Document information

Study
Uploaded on
May 22, 2026
Number of pages
9
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
627
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions