ARIZONA CONTRACTOR LICENSE CR 67 EXAM QUESTIONS WITH CORRECT SOLUTIONS||100% GUARANTEED PASS||UPDATED 2026/2027 SYLLABUS||ALREADY A+ GRADED||RECENT VERSION Even in a low voltage configuration, cables should be supported by? - ANSWER The building structure. A Class 1 Circuit stays between? - ANSWER The load side of the overcurrent device and the connected equipment. Whenever practicable, communications wires and cable should be located _______ electric light or power conductors. - ANSWER Below. You should not allow communications wires to be attached to a cross-arm if? - ANSWER the cross-arm carries electric power conductors. At the roof, you need to give communications cables a minimum vertical clearance of _______ feet from the points above which they pass. - ANSWER 8 feet A class _____ Circuit stays between the load side of a Class 2 power source and a connected equipment. - ANSWER 2 Circuit Remote -control circuits for use with safety - control equipment are considered Class _____ if failure to operate can introduce direct fire of life hazard. - ANSWER 1 Class 1 power -Limited Circuits should be supplied from a source that has a rated output of ______ volts or below only. - ANSWER 30 volts A class ______ circuits always considers safety from a fire initiation standpoint. - ANSWER 2 circuits Class 1 Power Sources other than transformers should have protection from overcurrent devices rated at max ______ of the volt -- ampere rating of the source divided by the rated voltage. - ANSWER 167% A Class ______ circuit permits higher voltage than a class 2 circuit. - ANSWER 3 circuit ________ refers to the max volts - ampere output after a single minute of operation disregarding load and overcurrent protection. - ANSWER VAmax _______ refers to the max output current under any noncapacitive load and with overcurrent protection skipped. - ANSWER Imax Class 1 Remote -Control and Signaling Circuits should never exceed. - ANSWER 600 volts A Class 3 circuit always considers safety from a fire initiation standpoint - ANSWER True Cables and conductors of class 2 and class 3 circuits should not be placed in a cable tray with conductors of electric light. - ANSWER True Any accessible portion of abandoned Class 2 cables. - ANSWER Should be removed The power output of the source of Class 1 Remote - Control and Signaling Circuit. - ANSWER Class 1 Remote - Control and Signaling Circuits are NOT required to be limited Class 1 circuit conductors and power - supply conductors that are not functionally associated? - ANSWER They should be separated by a solid fixed barrier. Class 1 circuit may occupy the same cable as long as? - ANSWER (AC or DC does not matter) As long as all conductors are insulated for the mex voltage of any conductor in the same cable.

Content preview

ARIZONA CONTRACTOR LICENSE CR-
67 EXAM QUESTIONS WITH CORRECT
SOLUTIONS||100% GUARANTEED
PASS||UPDATED 2026/2027
SYLLABUS||ALREADY A+
GRADED||<<RECENT VERSION>>
Even in a low voltage configuration, cables should be supported by? - ANSWER
✓ The building structure.

A Class 1 Circuit stays between? - ANSWER ✓ The load side of the overcurrent
device and the connected equipment.

Whenever practicable, communications wires and cable should be located
_______ electric light or power conductors. - ANSWER ✓ Below.

You should not allow communications wires to be attached to a cross-arm if? -
ANSWER ✓ the cross-arm carries electric power conductors.

At the roof, you need to give communications cables a minimum vertical
clearance of _______ feet from the points above which they pass. - ANSWER ✓ 8
feet

A class _____ Circuit stays between the load side of a Class 2 power source and a
connected equipment. - ANSWER ✓ 2 Circuit

Remote -control circuits for use with safety - control equipment are considered
Class _____ if failure to operate can introduce direct fire of life hazard. -
ANSWER ✓ 1

Class 1 power -Limited Circuits should be supplied from a source that has a rated
output of ______ volts or below only. - ANSWER ✓ 30 volts

,A class ______ circuits always considers safety from a fire initiation standpoint. -
ANSWER ✓ 2 circuits

Class 1 Power Sources other than transformers should have protection from
overcurrent devices rated at max ______ of the volt -- ampere rating of the source
divided by the rated voltage. - ANSWER ✓ 167%

A Class ______ circuit permits higher voltage than a class 2 circuit. - ANSWER
✓ 3 circuit

________ refers to the max volts - ampere output after a single minute of
operation disregarding load and overcurrent protection. - ANSWER ✓ VAmax

_______ refers to the max output current under any noncapacitive load and with
overcurrent protection skipped. - ANSWER ✓ Imax

Class 1 Remote -Control and Signaling Circuits should never exceed. - ANSWER
✓ 600 volts

A Class 3 circuit always considers safety from a fire initiation standpoint -
ANSWER ✓ True

Cables and conductors of class 2 and class 3 circuits should not be placed in a
cable tray with conductors of electric light. - ANSWER ✓ True

Any accessible portion of abandoned Class 2 cables. - ANSWER ✓ Should be
removed

The power output of the source of Class 1 Remote - Control and Signaling Circuit.
- ANSWER ✓ Class 1 Remote - Control and Signaling Circuits are NOT required
to be limited

Class 1 circuit conductors and power - supply conductors that are not functionally
associated? - ANSWER ✓ They should be separated by a solid fixed barrier.

Class 1 circuit may occupy the same cable as long as? - ANSWER ✓ (AC or DC
does not matter) As long as all conductors are insulated for the mex voltage of any
conductor in the same cable.

, Class 1 and Class 2 circuit should be identified at terminal and junction location. -
ANSWER ✓ True

Overcurrent protection should never exceed ______ amperes for 18 AWG
conductors? - ANSWER ✓ 7 amperes

Class 1 circuits conductors are normally allowed to be tapped? - ANSWER ✓
True

Overcurrent protection should never exceed _______ amperes for 16 AWG. -
ANSWER ✓ 10 amperes

Class 1 circuits and power - supply circuits may stay in the same raceway if? -
ANSWER ✓ If the equipment powered is functionally associated

Supply service drops of max 750 volts that run parallel to communications service
drops should posses a minimum separation of ______ inches at any point along the
span. - ANSWER ✓ 12 inches

talking about the definition of Imax. - ANSWER ✓ Refers to the max output
current under any noncapacitive load - this definition does not exclude short
circuit.

Cables and conductors of Class 2 circuits may be placed in a cable compartment
with conductors of non- power -limited fire alarm circuits. - ANSWER ✓ False

The length of an unlisted outside plant cable should be limited to _____ feet. -
ANSWER ✓ 50 feet

A primary protector should be located as close as practicable to where the cable
enters the building. - ANSWER ✓ True

Alternating Current (AC) - ANSWER ✓ AC always flows one way then the other.

Frequency of AC - ANSWER ✓ Measured in hertz Hz.

Electrical Signal - ANSWER ✓ Refers to a voltage that can convey information.

Document information

Uploaded on
May 21, 2026
Number of pages
30
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.59

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SmartscoreAaron
3.1
(7)
Sold
90
Followers
6
Items
4131
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions