⩥ New welds attaching existing shell plates to existing or new shell
plates should follow what two inspection methods? Answer: Visual and
RT


⩥ When a tank bottom is removed by using arc-gauging, the areas of the
tanks shell-to- bottom weld shall be? Answer: Magnetic-particle
examined and defective areas repaired and re-examined


⩥ At what frequency shall visible and fluorescent light meters used with
liquid penetrant testing be calibrated. Answer: A min. of once a year.


⩥ Fitness for service evaluations may be used to exempt a repair from
hydrostatic testing if performed by a? Answer: Engineer experienced in
tank design and evaluation methodologies used.


⩥ Flame arrestors should be inspected when? Answer: At appropriate
intervals.


⩥ When corrosion is found on the underside of a tank roof and the top
side of the tank shell, structural members such as roof girders and rafters

,will most likely be thinning at what rate? Answer: Twice the rate of the
roof or shell.


⩥ Assessment of internal tank settlement requires placement of
measurement points across the tank diameter at intervals of not more
than? Answer: 10 feet


⩥ In a API standard 653 repair a replacement plate meets but does not
cross a horizontal weld. prior to welding of a new vertical joint the
horizontal weld should be cut beyond the new vertical joint at min.
length of? Answer: 12 inches


⩥ Surface prep, anchor patterns typically required for coatings are
generally how many mils. deep? Answer: 1.5-4 Mils.


⩥ A limitation of PT is that standard penetrant systems are limited to
welds having a max temp. of? Answer: 125°F


⩥ In calibrating magnetizing equipment ammeter, what is the max
deviation allowed relative to the actual current value as shown by the
test meter? Answer: +/- 10%of full scale


⩥ The max deposition rate for pulsed arc transfer mode is? Answer:
About 200 in./min.

, ⩥ Consequence factors to consider in an RBI assessment of a tank
include? Answer: Mode of failure


⩥ The pattern of caustic cracking observed on the steel surface appears
sometimes as cracks that? Answer: Have spider-web appearance
initiating at weld flaws.


⩥ When a in-service tank inspection is performed, what is the
recommended method of documenting leaks on a riveted shell? Answer:
Locate leaks by sketch or photo.


⩥ An example of a non-essential variable for a tank bottom scanner
qualification test is? Answer: Plate cleanliness.


⩥ The annual cathodic protection surveys for a impressed current system
may? Answer: Include one or more electrical measurements performed
previously in the initial survey.


⩥ For tank repairs, safeguards for personal health and safety, and
prevention of property damage shall be developed to the guidelines
given in which standard. Answer: API 2015 and API 2217A


⩥ How far beyond the outer periphery of the foundation ring wall should
the drip ring extend? Answer: 3 inches

Document information

Uploaded on
April 28, 2026
Number of pages
20
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TopGradeInsider
4.1
(14)
Sold
202
Followers
1
Items
66156
Last sold
15 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions