, An acceptable reinforcing steel support mechanism for a 24-inch deep footing are?
-precast dobie blocks
-large,solid pieces of glass
-masonry CMU pieces
-wooden blocks - correct ans:Precast dobie blocks
all of the following are true except ?
---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches, unless they
are in a member that's permanently cast against earth
---specified concrete cover for headed shear stud reinforcement shall not be less then the cover
requirement for the member in which the stud reinforcement is located
---Concrete cover for the flexural members, walls, and compression members with an effective depth of
8-inches can vary -3/8 of an inch
---Concrete cover for members in highly corrosive environments will typically remain the same as cast
against earth - correct ans:Concrete cover for members in highly corrosive environments will typically
remain the same as cast agonist earth
As a general rule, Lap splicing bar larger then NO.11 Is?
-not permitted
-permitted
-permitted if bars will be in tension within the structural member
-permitted only if bars are within a bundle - correct ans:not permitted
before new concrete is placed, construction joints must be?
-blown free of dirt and debris
-wetted ,and standing water removed
-sand blasted
- treated with a bonding agent - correct ans:wetted, and standing water removed
grade 60 reinforcing steel has an ultimate strength of?
code test 60 Exam with
comprehensive questions and well
elaborated correct answers graded A+
Professional Academic Assistance Services
Services Offered
Proctored Exam Assistance
Online Class Management (Full Course Support)
Exam Preparation & Study Materials
Assignments and Coursework Support
Essays and Research Papers
Discussion Posts and Replies
Contact Information
Email:
WhatsApp: +254705994759
, An acceptable reinforcing steel support mechanism for a 24-inch deep footing are?
-precast dobie blocks
-large,solid pieces of glass
-masonry CMU pieces
-wooden blocks - correct ans:Precast dobie blocks
all of the following are true except ?
---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches, unless they
are in a member that's permanently cast against earth
---specified concrete cover for headed shear stud reinforcement shall not be less then the cover
requirement for the member in which the stud reinforcement is located
---Concrete cover for the flexural members, walls, and compression members with an effective depth of
8-inches can vary -3/8 of an inch
---Concrete cover for members in highly corrosive environments will typically remain the same as cast
against earth - correct ans:Concrete cover for members in highly corrosive environments will typically
remain the same as cast agonist earth
As a general rule, Lap splicing bar larger then NO.11 Is?
-not permitted
-permitted
-permitted if bars will be in tension within the structural member
-permitted only if bars are within a bundle - correct ans:not permitted
before new concrete is placed, construction joints must be?
-blown free of dirt and debris
-wetted ,and standing water removed
-sand blasted
- treated with a bonding agent - correct ans:wetted, and standing water removed
grade 60 reinforcing steel has an ultimate strength of?