Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 100 pages
Exam (elaborations)

Nevada C-7 Elevator Exam 2026 | 200 Practice Questions, Answers & Rationales | Pass Your Conveyance Contractor License First Try

Document preview thumbnail
Preview 4 out of 100 pages

Stop stressing over the Nevada C-7 Elevator & Conveyance Contractor exam – master the actual test with the most up-to-date practice guide for 2026! Whether you're applying for your C-7 license through the Nevada State Contractors Board (NSCB) or need to pass the trade exam for elevators, escalators, dumbwaiters, and platform lifts, this comprehensive PDF study guide gives you 200 realistic, exam-style questions – plus verified answers and detailed rationales – covering every topic you'll face on the official NSCB test. Why waste time with generic elevator quizzes? This guide is laser-focused on the exact content of the Nevada C-7 exam, including state-specific licensing rules, ASME codes (A17.1, A18.1, B20.1), safety requirements, and real-world troubleshooting scenarios. Nevada Licensing & Business Law (Q1-30) – NSCB jurisdiction, C-7 scope of work (passenger/freight elevators, escalators, moving walks, dumbwaiters, platform lifts – NO fire sprinklers), minimum bond ($5,000), biennial renewal, down payment limit (10% or $1,000), workers' comp requirements, qualifying individual experience (4 years), general liability ($250,000), license display rules, contract requirements (warranty – 1 year), home solicitation cooling-off period (3 days), mechanics liens, and disciplinary actions. ASME A17.1 Safety Code for Elevators & Escalators (Q31-70) – Minimum clearance (car sill to hoistway door: ¾ inch), hoistway door gap (5/8 inch), governor tripping speed (hydraulic: 115% of rated, traction: 115-130%), machine room illumination (20 foot-candles), door reopening force (30 lbf), escalator step chain safety factor (5:1), moving walk slope limit (12°), acceptance test (125% rated load), buffer requirements, phase reversal relay, unenclosed hydraulic travel limit (30 ft), escalator handrail speed tolerance (±2%), car enclosure impact resistance (250 lb/sq ft), emergency stop deceleration (1.0 g), MRL access (outside hoistway), pit depth minimum (24 inches for hydraulic), alarm sound level (80 dBA), final limit switches, skirt panel gap (4 mm), door restrictor, safeties (wedge/roller), minimum suspension ropes (3), emergency lighting duration (4 hours), hoistway door interlock, and periodic full load test (acceptance only unless alteration). Elevator Systems – Hydraulic, Traction, MRL (Q71-120) – Pascal's law, holed vs. holeless hydraulic, sinking car (check valve/cylinder leak), oil change interval (5 years), roped hydraulic, traction machine location (overhead), MRL machine (inside hoistway top), counterweight balance (car weight + 40% load), rope material (steel wire), governor trip speed (115% for traction), VVVF drive (energy efficient, smooth), overvoltage fault (braking resistor), magnetic brake (spring-applied, electrically released), leveling valve, oil carryover (zero), rope retirement criteria (10% broken wires, diameter reduction, rust), car frame components, manual rescue (hand wheel/brake release), guide shoe materials (nylon/bronze), regenerative drive, operating pressure (800-1200 psi for hydraulic), rupture valve (velocity fuse), encoder feedback, and inspection mode speed (30 fpm).

Content preview

Page 1 of 100



Nevada C 7 Elevator & Conveyance

Contractor Practice Exam 150 Question

And correct Answers.

1. The Nevada C-7 license is regulated by which state board?

A) Nevada Transportation Authority

B) Nevada State Contractors Board (NSCB)

C) Nevada Elevator Safety Board

D) Nevada Department of Business & Industry

Answer: B) Nevada State Contractors Board (NSCB)

Rationale: NSCB licenses all contractors in NV, including C-7

specialty.

2. A C-7 contractor may perform work on all EXCEPT:

A) Passenger elevators

B) Freight elevators

,Page 2 of 100


C) Residential stair lifts

D) Fire sprinkler systems

Answer: D) Fire sprinkler systems

Rationale: Fire sprinklers are a separate trade (C-16). C-7 is

limited to conveyances.

3. What is the minimum bond amount for a C-7 license in

Nevada?

A) $1,000

B) $2,500

C) $5,000

D) $10,000

Answer: C) $5,000

Rationale: NSCB requires $5,000 bond for specialty contractors.

4. A C-7 contractor must renew their license every:

A) 1 year

B) 2 years

,Page 3 of 100


C) 3 years

D) 5 years

Answer: B) 2 years

Rationale: Biennial renewal per NSCB.

5. Scenario: A C-7 contractor bids on a project to replace an

escalator in a Las Vegas casino. The contract value is $150,000.

What is the maximum down payment allowed by Nevada law?

A) 10% or $1,000, whichever is less

B) 15% or $1,500, whichever is less

C) 25% or $2,000, whichever is less

D) No limit

Answer: A) 10% or $1,000, whichever is less

Rationale: NAC 624.660 limits down payment on residential

projects; for commercial, the limit is 10% or $1,000 unless

contract states otherwise.

, Page 4 of 100


6. A C-7 contractor performs work without a permit. The penalty

can include:

A) Fine only

B) Stop work order and possible license suspension

C) No penalty if work is safe

D) Only a warning

Answer: B) Stop work order and possible license suspension

Rationale: NSCB enforces permit requirements.

7. Which of the following is NOT required to be included in a

C-7 contract for a residential elevator?

A) Total contract price

B) Start and completion dates

C) A detailed list of all subcontractors’ home addresses

D) Description of work and materials

Document information

Uploaded on
April 14, 2026
Number of pages
100
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$28.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PREPPERFECT
4.8
(3473)
Sold
423
Followers
60
Items
12068
Last sold
1 hour ago

Reviews from verified buyers




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions