Master UST installation with 130+ exam questions & answers. Covers tank handling, backfill, overfill prevention, cathodic protection & PEI/API standards. This comprehensive study guide is your essential resource for passing any Underground Storage Tank (UST) installation certification exam. Used by tank installers, environmental compliance officers, and petroleum equipment technicians, this guide contains 130+ practice questions with verified answers covering every aspect of proper UST installation. Updated for current regulatory requirements, this material addresses the most common causes of system failure—starting with improper installation—and provides the technical knowledge needed to ensure compliant, leak-free installations.

Content preview

U1 UST INSTALLATION/RETROFITTING EXAM COMPLETE
QUESTIONS AND VERIFIED SOLUTIONS LATEST UPDATE THIS
YEAR
1. One of the significant causes of leaks in underground liquid storage systems is
____________ ________________ - ANSWER-Improper Installation


2. Written Plans are required to - ANSWER-obtain permits, solicit bids, and
provide precise guidance for installers.


3. The plans should - ANSWER-Describe the property, identify the size and
location of the tanks, indicate the liquids to be stored and provide the location of
the dispensers and piping.


4. Storage systems discussed in this recommended practice are usually regulated
by - ANSWER-Federal, state or local agencies.


5. All owners should ensure that the equipment to be installed meets - ANSWER-
applicable regulatory requirements before being installed


6. Consult the local authorities who have jurisdiction in the area before storage-
system plans are - ANSWER-finalized or construction is initiated.


7. All owners should ensure that the equipment to be installed meets all applicable
regulatory requirements before - ANSWER-Being installed.


8. To avoid damage tanks must not be - ANSWER-dropped, dragged, or handled
with sharp objects.




1

,9. Tanks must not be dropped, dragged, or handled with sharp objects to avoid -
ANSWER-Damage to the tank


10. The only time tanks really should be moved is when - ANSWER-for
inspections and testing.


11. If a tanks is damaged at all throughout the moving process it must be -
ANSWER-Repaired in accordance with the manufacture's instructions.


12. The proper way to move a tank is by lifting it, using the - ANSWER-Lift lugs
that are installed by the manufacturer.


13. Tanks should be carefully lifted and lowered using - ANSWER-Cables or
chains of adequate length.


14. When two lifting lugs are being used, the angle between the lifting cable and
vertical should be no more than - ANSWER-30 degrees.


15. Stockpile piping materials and equipment in a _____________ _________ on
the job site - ANSWER-Secure area


16. Confirm adherence to specifications by reporting to the owner about any -
ANSWER-detected damage that could result in leakage or premature corrosion.


17. Pressure test single-walled tanks with _____ to _______ psig air pressure,
soaping all surfaces, seams and fittings while inspecting for bubbles. - ANSWER-3
to 5




2

, 18. Air testing with over ___ psig (3 Psig for 12-Ft. Diameter FRP tanks) is
hazardous and may damage the tank - ANSWER-5 psig


19. Do not air test a tank that has previously contained - ANSWER-flammable or
combustible liquids


20. Place ______ barricades at the ends of tanks being tested. - ANSWER-
Warning


21. Avoid tank ends, man-ways, and fittings while the tank is under - ANSWER-
Pressure


22. Release pressure in the tank before disconnecting any - ANSWER-gauges or
test fittings.


23. Be aware some manufactures do not tighten fittings to allow for
_____________ _____________ during shipping and storage. - ANSWER-
Temperature changes


24. True or False: Air tests are inconclusive without soaping and careful inspection
for bubbles? - ANSWER-True


25. Tanks gauges must have a scale that will permit detection of small changes in
__________ that might go undetected on gauges with a ___________ _________.
- ANSWER-Pressure, broader range.


26. Since the best accuracy of gauges is at mid-range, and test pressures must not
exeed 5 psig, use a gauge with a maximum limit of ____ or ______ - ANSWER-10
or 15 psig

3

Document information

Uploaded on
April 13, 2026
Number of pages
26
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
VeritasShelf1
3.0
(1)
Sold
6
Followers
0
Items
229
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions