EPA 608 Certification, EPA 608 2026/2027 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || GUARANTEED PASS 1. The charging valve on the evaporator. - ANSWER When the refrigerant is put back into a Type III chiller, following recovery and system repair, where is it added? 2. Hydrostatic (tube) test - ANSWER What method is used to find suspected water tube leaks in chillers? 3. 130-Degrees F - ANSWER What temperature should be attained when removing oil from a low pressure system to ensure a lower level of refrigerants in the oil? 4. 15 PSIG - ANSWER The typical design burst pressure for a rupture disc is what? 5. Tube Leakage - ANSWER Excessive moisture collection in the purge unit can indicate what? 6. 500 microns - ANSWER Vacuum pumps need to be capable of pulling what level of vacuum? 7. 35% - ANSWER All refrigeration systems containing more than 50 lbs. of refrigerant must be repaired when the annual leak rate exceeds___? 8. Controlled hot water or heater blankets. - ANSWER The most efficient method of leak checking a charged low-pressure system is to use? 9. At the shaft seal. - ANSWER Systems with open drive compressors are prone to leak where? 10. A refrigerant monitor that will sound and alarm and automatically start a ventilation system in equipment rooms before the refrigerant concentration reaches the TLV-TWA. - ANSWER What does ASHRAE standard 15 require? 11. Threshold Limit Value, Time Weighted Average - ANSWER TLV-TWA 12. Oxygen Deprivation Sensor - ANSWER A-1 Group Refrigerants only require what? 13. "Refrigerant Specific" Mechanical Room Sensor. - ANSWER All "B" rated refrigerants require what? 14. They are heat removal devices used to transfer process waste heat to the atmosphere. - ANSWER What are Cooling Towers? 15. 10 psig - ANSWER What is the maximum test pressure to use for pressurizing Type III centrifugal systems with nitrogen? 16. 36F - ANSWER Enough vapor has entered the system and you may begin charging liquid refrigerant when the refrigerant saturation temperature increases to? 17. Small appliances- 5lbs or less - ANSWER Type 1 18. Residental Units/ Light Commercial - ANSWER Type 2 19. Industrial - ANSWER Type 3 20. All types - ANSWER Universal 21. Nov 14th, 1994 - ANSWER Section 608 of the federal clean air act requires all persons who maintain, service, repair or dispose of appliances that contain regulated refrigerants, be certified in proper refrigerant handling techniques as of 22. Low Loss Fitting - ANSWER What is used to cause a minimal amount of refrigerant to be released? 23. R-11, R-12, R-113, R-114,R-115 - ANSWER CFC Refrigerants 24. R-22, R-123, R-124, R-1426 - ANSWER HCFC Refrigerants 25. R-125, R-134A, R-23, R-32, R-125, R-143a, R-152A - ANSWER HFC Refrigerants 26. Blue Hose - ANSWER The compound gauge of the manifold that measures low pressure (psig) and vacuum (inches Hg.) is what color? 27. Red Hose - ANSWER The high pressure gauge of the manifold that measures the high side (discharge) pressure is what color? 28. Yellow Hose - ANSWER The center port of the manifold that can be connected to a recovery device, evacuation vacuum pump or charging device is what color? 29. De- Minimus - ANSWER The Latin word for the least amount of Refrigerant you can release into the atmosphere? 30. 2020 - ANSWER HFC's will be Phased out by? 31. December 31st, 1995 - ANSWER CFC's were phased out of production by? 32. Global Warming Potential - ANSWER GWP 33. Air Conditioning/ Refrigeration Institute (Govern standards covering subjects of air conditioning, refrigeration, and heating industry) - ANSWER ARI 34. November 15th, 1993 - ANSWER After what date must refrigerants be certified and labeled by EPA Approved Equipment Testing Organizations to meet EPA Standards?

Content preview

EPA 608 Certification, EPA 608 2026/2027
COMPLETE QUESTIONS WITH CORRECT
DETAILED ANSWERS || GUARANTEED
PASS


1. The charging valve on the evaporator. - ANSWER ✅ When the refrigerant
is put back into a Type III chiller, following recovery and system repair,
where is it added?


2. Hydrostatic (tube) test - ANSWER ✅ What method is used to find
suspected water tube leaks in chillers?


3. 130-Degrees F - ANSWER ✅ What temperature should be attained when
removing oil from a low pressure system to ensure a lower level of
refrigerants in the oil?


4. 15 PSIG - ANSWER ✅ The typical design burst pressure for a rupture disc
is what?


5. Tube Leakage - ANSWER ✅ Excessive moisture collection in the purge
unit can indicate what?


6. 500 microns - ANSWER ✅ Vacuum pumps need to be capable of pulling
what level of vacuum?

,7. 35% - ANSWER ✅ All refrigeration systems containing more than 50 lbs.
of refrigerant must be repaired when the annual leak rate exceeds___?


8. Controlled hot water or heater blankets. - ANSWER ✅ The most efficient
method of leak checking a charged low-pressure system is to use?


9. At the shaft seal. - ANSWER ✅ Systems with open drive compressors are
prone to leak where?


10.A refrigerant monitor that will sound and alarm and automatically start a
ventilation system in equipment rooms before the refrigerant concentration
reaches the TLV-TWA. - ANSWER ✅ What does ASHRAE standard 15
require?


11.Threshold Limit Value, Time Weighted Average - ANSWER ✅ TLV-TWA


12.Oxygen Deprivation Sensor - ANSWER ✅ A-1 Group Refrigerants only
require what?


13."Refrigerant Specific" Mechanical Room Sensor. - ANSWER ✅ All "B"
rated refrigerants require what?


14.They are heat removal devices used to transfer process waste heat to the
atmosphere. - ANSWER ✅ What are Cooling Towers?


15.10 psig - ANSWER ✅ What is the maximum test pressure to use for
pressurizing Type III centrifugal systems with nitrogen?

,16.36F - ANSWER ✅ Enough vapor has entered the system and you may
begin charging liquid refrigerant when the refrigerant saturation temperature
increases to?


17.Small appliances- 5lbs or less - ANSWER ✅ Type 1


18.Residental Units/ Light Commercial - ANSWER ✅ Type 2


19.Industrial - ANSWER ✅ Type 3


20.All types - ANSWER ✅ Universal


21.Nov 14th, 1994 - ANSWER ✅ Section 608 of the federal clean air act
requires all persons who maintain, service, repair or dispose of appliances
that contain regulated refrigerants, be certified in proper refrigerant handling
techniques as of


22.Low Loss Fitting - ANSWER ✅ What is used to cause a minimal amount of
refrigerant to be released?


23.R-11, R-12, R-113, R-114,R-115 - ANSWER ✅ CFC Refrigerants


24.R-22, R-123, R-124, R-1426 - ANSWER ✅ HCFC Refrigerants


25.R-125, R-134A, R-23, R-32, R-125, R-143a, R-152A - ANSWER ✅ HFC
Refrigerants

, 26.Blue Hose - ANSWER ✅ The compound gauge of the manifold that
measures low pressure (psig) and vacuum (inches Hg.) is what color?


27.Red Hose - ANSWER ✅ The high pressure gauge of the manifold that
measures the high side (discharge) pressure is what color?


28.Yellow Hose - ANSWER ✅ The center port of the manifold that can be
connected to a recovery device, evacuation vacuum pump or charging device
is what color?


29.De- Minimus - ANSWER ✅ The Latin word for the least amount of
Refrigerant you can release into the atmosphere?


30.2020 - ANSWER ✅ HFC's will be Phased out by?


31.December 31st, 1995 - ANSWER ✅ CFC's were phased out of production
by?


32.Global Warming Potential - ANSWER ✅ GWP


33.Air Conditioning/ Refrigeration Institute (Govern standards covering
subjects of air conditioning, refrigeration, and heating industry) - ANSWER
✅ ARI


34.November 15th, 1993 - ANSWER ✅ After what date must refrigerants be
certified and labeled by EPA Approved Equipment Testing Organizations to
meet EPA Standards?

Document information

Uploaded on
April 12, 2026
Number of pages
37
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
DrMwendwa
2.0
(2)
Sold
4
Followers
0
Items
518
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions