1)A2WhenA2isA2theA2BESTA2timeA2toA2documentA2eachA2loopA2checkA2forA2commissioningA
2?A2A.A2PriorA2toA2theA2startA2ofA2inspectionA2
B.A2WhenA2allA2testA2andA2inspectionA2activitiesA2areA2completeA2
C.A2WhenA2updatingA2informationA2onA2aA2dailyA2basisA2
D.A2AtA2theA2timeA2eachA2testA2isA2completedA2-A2Ans--
D.A2AtA2theA2timeA2eachA2testA2isA2completedA2(INSTA2LVL4)(12410-16/A2SectionA23.2.0)

2)A2TeflonA2pasteA2mustA2notA2beA2usedA2onA2:A2
A.A2NitrogenA2serviceA2
B.A2NaturalA2gasA2serviceA2
C.A2WaterA2serviceA2
D.A2OxygenA2serviceA2-A2Ans--D.A2OxygenA2serviceA2(INSTA2LVLA21A2)(12109-14/
SectionA22.1.1)

3)A2AA224VDCA2powerA2supplyA2isA2notA2workingA2.A2WithA2yourA2multimeterA2youA2verifyA2
noA2DCA2voltageA2.A2OnA2theA2120VACA2inputA2youA2measureA2120VA2betweenA2hotA2and
A2groundA2,A2andA272VA2betweenA2hotA2andA2neutralA2.A2WhatA2isA2theA2mostA2likelyA2caus
eA2ofA2thisA2?A2
A.A2LostA2theA2groundA2
B.A2LostA2theA2hotA2
C.A2LostA2theA2neutralA2
D.A2LostA2theA2fuseA2-A2Ans--C.A2LostA2theA2neutral

4)A2GainA2increaseA2whenA2tubeA2:A2
A.A2BackA2bendsA2areA2madeA2
B.A2BendA2radiusA2increasesA2
C.A2SizeA2decreasesA2
D.A2LongA2radiusA2elbowsA2areA2usedA2-A2Ans--
B.A2BendA2radiusA2increasesA2(INSTA2LVLA22)(12302-15A2sectionA22.1.1)

5)A2AA2temperatureA2measuringA2deviceA2thatA2producesA2aA2voltageA2asA2theA2temperatu
reA2changesA2isA2aA2/A2anA2:A2
A.A2RTDA2
B.A2ThermistorA2
C.A2ThermometerA2
D.A2ThermocoupleA2-A2Ans--D.A2ThermocoupleA2(INSTA2LVLA22)A2(12110-
15A2sectionA21.2.2)

6)A2AA2pressureA2pipingA2codeA2isA2foundA2inA2:A2
A.A2ANSIA2BA231.1A2
B.A2NECA2690A2.A2

,C.A2OSHA1910A2.A2
D.A2ISAA2SA25.1A2-A2Ans--A.A2ANSIA2BA231.1

7)A2WhenA2markingA2tubingA2forA2cuttingA2,A2theA2preferredA2methodA2isA2
A.A2ScribeA2aA2markA2intoA2theA2tubeA2withA2aA2sharpA2objectA2.A2
B.A2MarkA2theA2tubeA2withA2aA2greaseA2pencilA2
C.A2MarkA2theA2tubeA2withA2aA2feltA2tipA2penA2
D.A2MarkA2theA2tubeA2withA2aA2crayonA2-A2Ans--C.A2MarkA2theA2tubeA2withA2aA2feltA2tipA2pen

8)A2AnA2exampleA2ofA2directA2measurementA2indicatorA2isA2aA2:A2
A.A2PressureA2gaugeA2
B.A2BulbA2thermometerA2
C.A2SightA2glassA2
D.A2FlowmeterA2-A2Ans--C.A2SightA2glass

9)A2OnA2theA2imageA2,A2howA2manyA2handA2valvesA2areA2installedA2onA2TankA21201CA2
A.A21A2
B.A22A2
C.A23A2
D.A24A2-A2Ans--C.A23

10)A2WhatA2isA2theA2firstA2stepA2inA2troubleshootingA2aA2problemA2inA2aA2systemA2?A2
A.A2TurnA2offA2powerA2toA2theA2instrumentA2
B.A2StimulateA2anA2inputA2
C.A2VerifyA2thatA2thereA2isA2aA2problemA2
D.A2StimulateA2anA2outputA2-A2Ans--C.A2VerifyA2thatA2thereA2isA2aA2problem

11)A2WhereA2canA2theA2appropriateA2elevationA2ofA2anA2instrumentA2beA2foundA2?A2
A.A2LocationA2drawingA2
B.A2PA2&A2IDA2
C.A2FlowA2diagramA2
D.A2LoopA2drawingA2-A2Ans--A.A2LocationA2drawing

12)A2ChemicalA2cleaningA2ofA2tubingA2attachedA2toA2instrumentsA2mayA2causeA2damageA2
toA2sensorA2
A.A2ElectronicsA2
B.A2PaintA2
C.A2ElementsA2
D.A2BoltsA2-A2Ans--C.A2Elements

13)A2WhenA2makingA290A2-
A2degreeA2tubingA2bendA2,A2allowanceA2forA2springbackA2shouldA2beA2:A2A.A26A2toA28A2degr
eesA2
B.A24-5A2degreesA2
C.A21A2toA23A2degreesA2
D.A20A2degreesA2-A2Ans--C.A21A2toA23A2degrees

,14)A2CableA2shieldsA2shouldA2beA2connectedA2toA2theA2:A2
A.A2SignalA2groundA2referenceA2pointA2
B.A2GroundA2atA2eachA2accessibleA2locationA2
C.A2FirstA2accessibleA2groundingA2electrodeA2
D.A2RacewayA2orA2cableA2trayA2inA2whichA2theA2cableA2isA2routedA2-A2Ans--
B.A2GroundA2atA2eachA2accessibleA2location

15)A2AnA2employeeA2deA2energizesA2aA2pieceA2ofA2equipmentA2byA2removingA2theA2power
A2plugA2fromA2theA2outletA2.A2IfA2theA2employeeA2continuesA2toA2holdA2onA2toA2theA2powerA2
plugA2onceA2removedA2,A2thisA2employeeA2isA2saidA2toA2haveA2whatA2typeA2ofA2controlA2ov
erA2theA2energyA2potentialA2?A2
A.A2IsolationA2controlA2
B.A2LockoutA2tagoutA2
C.A2ExclusiveA2controlA2
D.A2RemoteA2controlA2-A2Ans--C.A2ExclusiveA2control

16)A2AA2compressorA2keepsA2blowingA2aA2PSVA2forA2troubleshootingA2aA2technicianA2sho
uldA2startA2lookingA2atA2
A.A2PowerA2switchA2settingA2
B.A2PressureA2switchA2deadbandA2
C.A2LevelA2switchA2settingA2
D.A2FloatA2swichA2deadbandA2-A2Ans--B.A2PressureA2switchA2deadband

17)A2InA2theA2figureA2providedA2theA2pipeA2lineA2thatA2carriesA2workingA2processA2fluidA2su
chA2asA2steamA2waterA2orA2gasA2isA2labeledA2asA2
A.A2AA2
B.A2BA2
C.A2CA2
D.A2DA2-A2Ans--A.A2A

18)A2AA2heatA2reactiveA2dryerA2isA2producingA2dampA2instrumentA2airA2whatA2couldA2beA2a
A2simpleA2fixA2
A.A2ReplaceA2desiccantA2
B.A2ChangeA2toA2aA2differentA2desiccantA2
C.A2AdjustA2theA2cycleA2timeA2
D.A2AddA2aA2secondA2setA2ofA2dryersA2-A2Ans--C.A2AdjustA2theA2cycleA2time

19)A2TypeA2JA2thermocoupleA2extensionA2wireA2isA2
A.A2WhiteA2&A2redA2
B.A2YellowA2&A2redA2
C.A2BlueA2&A2redA2
D.A2GreenA2&A2redA2-A2Ans--A.A2WhiteA2&A2red

20)A2WhichA2ofA2theA2followingA2gasesA2shouldA2beA2usedA2toA2purgeA2tubingA2andA2pipeA2
afterA2cleaningA2

, A.A2argonA2
B.A2AirA2
C.A2NitrogenA2
D.A2heliumA2-A2Ans--C.A2Nitrogen

21)A2WhenA2pressureA2testingA2,A2theA2requiredA2documentationA2includesA2:A2
A.A2SpecificationA2sheetsA2
B.A2TroubleshootingA2flowA2chartsA2
C.A2TemperatureA2,A2pressureA2,A2andA2testA2mediumA2
D.A2RequiredA2correctiveA2measuresA2-A2Ans--
C.A2TemperatureA2,A2pressureA2,A2andA2testA2medium

22)AnA2airA2-A2toA2-A2openA2valveA2usesA2
aA2:A2A.A2FailA2-A2inA2-A2positionA2actuatorA2
B.A2SpringA2-A2toA2-A2openA2actuatorA2
C.A2DualA2springA2actuatorA2
D.A2SpringA2-A2toA2-A2closeA2actuatorA2-A2Ans--D.A2Spring-to-closeA2Actuator

23)A2TheA2MOSTA2commonA2methodA2usedA2toA2measureA2theA2flowA2ofA2liquidA2inA2aA2pi
peA2isA2toA2introduceA2aA2restrictionA2inA2theA2pipeA2andA2measureA2theA2:A2
A.A2Velocity
B.A2PressureA2
C.A2DifferentialA2pressureA2
D.A2ViscosityA2-A2Ans--A.A2Velocity

24)A2WhatA2isA2theA2resistanceA2inA2theA2circuitA2?A2
A.A250A2ohmsA2
B.A2100A2ohmsA2
C.A2150A2ohmsA2
D.A2200A2ohmsA2-A2Ans--D.A2200A2ohms

25)A2AfterA2aA2bendA2isA2completedA2,A2allA2tubingA2willA2exhibitA2:A2
A.A2HardnessA2
B.A2SpringbackA2
C.A2BendingA2errorsA2
DiscolorationA2-A2Ans--B.A2Springback

26)A2WhatA2valveA2REQUIRESA2aA290A2-
A2degreeA2turnA2toA2operateA2theA2valveA2100A2%A2openA2orA2closedA2?A2
AA2GlobeA2valveA2
B.A2CheckA2valveA2
C.A2GateA2valveA2
D.A2BallA2valveA2-A2Ans--D.A2BallA2valve

27)A2WhereA2isA2theA2drainA2wireA2terminatedA2inA2instrumentA2systemA2?A2
A.A2AtA2theA2conduitA2

Document information

Uploaded on
April 8, 2026
Number of pages
35
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
LECTUREKIM
1.0
(2)
Sold
12
Followers
0
Items
3989
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions