NICET Level II Question and answer already passed 2025/2026 Addressable Device - correct answer A fire alarm system component with an input, output, or combination function, that is dsicreetly identified by a unique address. (NFPA 72, 3.3.8) Addressable Fire Alarm System - correct answer A system in which the fire alarm control unit and its associated devices are connected and communicate digitally. Each device is separately addressed. Alarm Condition - correct answer An abnormal condition that poses an immediate threat to life, property, or mission. (NFPA 72 2022, Section 3.3.65.1.1) Alarm Signal - correct answer A signal that results from the manual or automatic detection of an alarm condition. (NFPA 72 2022, Section 3.3.272.1) AHJ (Authority having Jurisdiction) - correct answer An organization, office, or individual responsible for enforcing requirements of a code or standard, or for approving equipment, materials, an installation, or a procedure. (NFPA 72 2022, Section 3.2.2) Ancillary Functions - correct answer Non-emergency activations of the fire alarm or mass notification audible, visual, and textual output circuits. (NFPA 72 2022, Section 3.3.20) Audible Notification Appliance - correct answer A notification appliance that alerts by the sense of hearing. (NFPA 72 2022, Section 3.3.189.1)

Content preview

NICET Level II Question and answer
already passed 2025/2026
Addressable Device - correct answer ✔A fire alarm system component with an input, output, or
combination function, that is dsicreetly identified by a unique address. (NFPA 72, 3.3.8)



Addressable Fire Alarm System - correct answer ✔A system in which the fire alarm control unit and its
associated devices are connected and communicate digitally. Each device is separately addressed.



Alarm Condition - correct answer ✔An abnormal condition that poses an immediate threat to life,
property, or mission. (NFPA 72 2022, Section 3.3.65.1.1)



Alarm Signal - correct answer ✔A signal that results from the manual or automatic detection of an
alarm condition. (NFPA 72 2022, Section 3.3.272.1)



AHJ (Authority having Jurisdiction) - correct answer ✔An organization, office, or individual responsible
for enforcing requirements of a code or standard, or for approving equipment, materials, an installation,
or a procedure. (NFPA 72 2022, Section 3.2.2)



Ancillary Functions - correct answer ✔Non-emergency activations of the fire alarm or mass notification
audible, visual, and textual output circuits. (NFPA 72 2022, Section 3.3.20)



Audible Notification Appliance - correct answer ✔A notification appliance that alerts by the sense of
hearing. (NFPA 72 2022, Section 3.3.189.1)



Automatic Fire Detector - correct answer ✔A device designed to detect the presence of a fire signature
and to initiate action. (NFPA 72 2022, Section 3.3.77.2)

, Autonomous Control Unit - correct answer ✔The primary control unit for an in-building mass
notification system. (NFPA 72 2022, Section 3.3.69.1)



Central Station Service - correct answer ✔The use of a system or a group of systems including the
protected premises fire alarm system(s) in which the operations of circuits and devices are signaled to,
recorded in, and supervised from a listed central station that has competent and experienced operators
who, upon receipt of a signal, take such action as required by this Code. Related activities at the
protected premises, such as equipment installation, inspection, testing, maintenance, and runner
service, are the responsibility of the central station or a listed alarm service local company. Central
station service is controlled and operated by a person, firm, or corporation whose business is the
furnishing of such contracted services or whose properties are the protected premises. (NFPA 72 2022,
Section 3.3.303.1)



Central Station Service Alarm System - correct answer ✔A system or group of systems in which the
operations of circuits and devices are transmitted automatically to, recorded in, maintained by, and
supervised from a listed central station that has competent and experienced servers and operators who,
upon receipt of a signal, take such action as required by this Code. Such service is to be controlled and
operated by a person, firm, or corporation whose business is the furnishing, maintaining, or monitoring
of supervised alarm systems. (NFPA 72 2022, Section 3.3.302.1)



Central Supervising Station - correct answer ✔A supervising station that is listed for central station
service and that also commonly provides less stringent supervising station services such as remote
supervising systems. (NFPA 72 2022, Section 3.3.301.1)



Control Unit (Fire Alarm Control Unit-FACU or FACP) - correct answer ✔A component of the fire alarm
system that receives signals from initiating devices or other fire alarm control units and processes these
signals to determine part or all of the required fire alarm system output function(s). (NFPA 72 2022,
Section 3.3.115)



Also known as the Fire Alarm Control Panel (FACP), or control panel..



Conventional Fire Alarm System - correct answer ✔A fire alarm system that consists of a control panel
employing one or more initiating circuits, wired in parallel. The system is not capable of identifying the
device that is in alarm, supervisory, or trouble status.

Document information

Uploaded on
April 4, 2026
Number of pages
11
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
flyhigher329
3.7
(61)
Sold
386
Followers
175
Items
18525
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions