NFPA 10 EXAM WITH VERIFIED QUESTIONS AND ANSWERS|| GUARANTEED PASS|| ALREADY GRADED A+ Extinguishers listed for the Class C rating shall not contain an agent that is a conductor of ________ - ANSWER-Electricity Dry chemical stored pressure extinguishers manufactured prior to _____________ shall be removed from service at the next 6 year maintenance interval or the next hydrostatic test whichever comes first - ANSWER-October 1984 Any fire extinguisher that can no longer be serviced in accordance with the manufacturers maintenance manual is considered to be _______ and shall be ________ from service - ANSWER-obsolete, removed Class A fires involve - ANSWER-Common Combustibles such as paper, wood, cloth, rubber, plastics Class B fires involve - ANSWER-Usually involve flammable liquids, greases, tars oils, paints, alcohols, and flammable gases Class C fires involve - ANSWER-Usually involve live electrical equipment Class D fires involve - ANSWER-Fires involving combustible metals such as magnesium, titanium, zirconium, sodium, and potassium. Class K fires involve - ANSWER-cooking appliances that involve combustible cooking media (vegetable or animal oils and fats). Is a wheeled fire extinguisher considered a portable fire extinguisher? - ANSWER-Yes Portable fire extinguishers shall be ______ and _____ and meet all of the requirements of one of the fire test standards indicated - ANSWER-listed and labeled Fire extinguishers having a gross weight not exceeding 40lbs shall be installed so that the top of the extinguisher is no more the _______ ft above the floor - ANSWER-5 Fire extinguishers having a gross weight greater than 40lbs shall be installed so that the top of the extinguisher is no more the _______ ft above the floor - ANSWER-3.5 In no case shall the clearance between the bottom of the extinguisher and the floor be less than ______ - ANSWER-4in HMIS, 6 year, hydrostatic test or other labels shall not be placed on what part of the extinguisher? - ANSWER-the front What is the minimum Class A rating for a single fire extinguisher for light and ordinary hazard occupancy/ - ANSWER-2-A For a 3000 sq ft facility, how many 2-A rated extinguishers would be required for ordinary hazard occupancy? - ANSWER-2 What is the maximum travel distance to a Class A extinguisher? - ANSWER 75ft What is the minimum travel distance to a 20-B rated extinguisher in an ordinary area? - ANSWER-50ft How should hazard areas involving Class B fires in flammable liquids of appreciable depth that are not manned all of the time be protected? - ANSWER By fixed systems Travel distances for portable extinguishers used to protect flammable liquids of appreciable depth shall not exceed ____ ft - ANSWER-50 What Class extinguishers are required to have a rating number preceding the classification letter that indicates the relative extinguishing effectiveness - ANSWER-Class A or B Class C, D, and K extinguishers are not required to have what? - ANSWER number preceding the classification letter The use of a halogenated fire extinguisher shall be limited to applications where a ______ _______ is necessary to extinguish effectively without damaging the equipment OR where the use of alternative agents have the potential to cause a hazard to ________ - ANSWER-clean agent

Content preview

NFPA 10 EXAM WITH VERIFIED QUESTIONS
AND ANSWERS|| GUARANTEED PASS||
ALREADY GRADED A+




Extinguishers listed for the Class C rating shall not contain an agent that is a
conductor of ________ - ANSWER-Electricity


Dry chemical stored pressure extinguishers manufactured prior to
_____________ shall be removed from service at the next 6 year maintenance
interval or the next hydrostatic test whichever comes first - ANSWER-October
1984


Any fire extinguisher that can no longer be serviced in accordance with the
manufacturers maintenance manual is considered to be _______ and shall be
________ from service - ANSWER-obsolete, removed


Class A fires involve - ANSWER-Common Combustibles such as paper, wood,
cloth, rubber, plastics


Class B fires involve - ANSWER-Usually involve flammable liquids, greases,
tars oils, paints, alcohols, and flammable gases


Class C fires involve - ANSWER-Usually involve live electrical equipment


Class D fires involve - ANSWER-Fires involving combustible metals such as
magnesium, titanium, zirconium, sodium, and potassium.

, Class K fires involve - ANSWER-cooking appliances that involve combustible
cooking
media (vegetable or animal oils and fats).


Is a wheeled fire extinguisher considered a portable fire extinguisher? -
ANSWER-Yes


Portable fire extinguishers shall be ______ and _____ and meet all of the
requirements of one of the fire test standards indicated - ANSWER-listed and
labeled


Fire extinguishers having a gross weight not exceeding 40lbs shall be installed
so that the top of the extinguisher is no more the _______ ft above the floor -
ANSWER-5


Fire extinguishers having a gross weight greater than 40lbs shall be installed so
that the top of the extinguisher is no more the _______ ft above the floor -
ANSWER-3.5


In no case shall the clearance between the bottom of the extinguisher and the
floor be less than ______ - ANSWER-4in


HMIS, 6 year, hydrostatic test or other labels shall not be placed on what part of
the extinguisher? - ANSWER-the front


What is the minimum Class A rating for a single fire extinguisher for light and
ordinary hazard occupancy/ - ANSWER-2-A


For a 3000 sq ft facility, how many 2-A rated extinguishers would be required
for ordinary hazard occupancy? - ANSWER-2

Document information

Uploaded on
April 1, 2026
Number of pages
15
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
14
Followers
1
Items
1615
Last sold
2 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions