the Texas mold assessment and remediation rules states that notice signs must be
legible from - CORRECT ANSWER✅✅10 feet
after completing any training course required by the Texas mold assessment and
remediation rules, how long do you have to take and pass the state examination -
CORRECT ANSWER✅✅6 months
the assigned protection factor (PF) for an N-95 respirator is - CORRECT
ANSWER✅✅there is no PF rating for an N-95 respirator
According to the EPA"mold remediation in schools and commercial buildings"
document, the EPA recommends the following for cleanup of books and papers that
were damaged with clear water within 24-48 hours - CORRECT ANSWER✅✅discard
all books and papers, photocopy and discard originals, and freeze or freeze-dry
originals
when sampling with a spore trap you are usually trying to determine - CORRECT
ANSWER✅✅identification of viable mild spores
which of the following sampling devices would you use to determine respirable and non-
respirable viable airborne mold spores? - CORRECT ANSWER✅✅air-o-cell cassette
according to the Texas mold assessment and remediation rules, if a contractor is
working under the exceptions and exemptions subsection and identifies additional mold
that affects a total surface area of more than 25 contiguous square feet they shall -
CORRECT ANSWER✅✅Immediately cease all remediation work and implement
emergency containment if necessary
according to the Texas mold assessment and remediation rules, a containment area is
defined as - CORRECT ANSWER✅✅an area that has been enclosed to control the
release of mold or mold-containing vapors into the surrounding area
a musty odor indoors usually indicates - CORRECT ANSWER✅✅microbial growth
skin and eye protection during the remediation process is used to protect workers from -
CORRECT ANSWER✅✅mold toxins and spores, dust mites, and cleaning products
, according to the Texas mold assessment and remediation rules the required clearance
level of mold spores is - CORRECT ANSWER✅✅N/A
which sampling method would you use to determine both viable and non- viable mold
concentrations in the air - CORRECT ANSWER✅✅air-o-cell-cassette
according to the EPA's "mold remediation in schools and commercial buildings"
document, the EPA recommends the following for cleanup for non-porous hard surface
areas - CORRECT ANSWER✅✅cleaned with detergent solution
what is the normal air flow rate an air-o-cell cassette - CORRECT ANSWER✅✅15
liters/minute
according to the. EPA's "mold remediation in schools and commercial buildings", it is
recommended that water damaged cellulose ceiling tiles should. be - CORRECT
ANSWER✅✅discarded
what is the normal air flow rater used for an Andersen sampler - CORRECT
ANSWER✅✅28.3 liters/minute
according to the Texas mold assessment and remediation rules, who can write a mold
management plan? - CORRECT ANSWER✅✅a licensed mold assessment consultant
according to the Texas mold assessment and remediation rules, a mold assessment
consultant may perform an assessment to - CORRECT ANSWER✅✅collect data for
writing a mold assessment report
health effects from inhalation of mold spores could be - CORRECT
ANSWER✅✅Hypersensitivity pneumonitis
according to the Texas mold assessment and remediation rules, mold is defines as -
CORRECT ANSWER✅✅spores, hyphae, mycotoxins, and living or dead fungi
according to the Texas mold assessment and remediation rules, the purpose of a mold
assessment is to - CORRECT ANSWER✅✅determine the sources, locations and
extent of mold growth in a building / determine the condition(s) that caused the mold
growth / and enable the assessment consultant to prepare a mold remediation protocol
according to the Texas mold assessment and remediation rules, a licensed mold
assessment company or consultant shall maintain records until - CORRECT
ANSWER✅✅the company or consultant issues a mold assessment report,
management plan, or remediation protocol to a client, if the company or consultant
performs. only the initial assessment for the project / the company or consultant issues
the final. status report to the client, if a. final status report is issued / and the company or