• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 8 pages
Exam (elaborations)

NCIDQ – Practicum Exam with all Correct & 100% Verified Answers |Latest Version |Already Graded A+

Document preview thumbnail
Preview 2 out of 8 pages

NCIDQ – Practicum Exam with all Correct & 100% Verified Answers |Latest Version |Already Graded A+

Content preview

NCIDQ – Practicum Exam with all Correct & 100%
Verified Answers |Latest Version |Already Graded A+

In wet areas, what are the requirements for wall finishes? ✔Correct Answer-- walls within 2' or
service sinks, toilets, or urinals are required to be constructed of moisture resistant material (cement
board, X) and are required to have tile (or similar) finish up to minimum 4' AFF. Wallcovering may be
used above 4' AFF. Lavatories do not count as a service sink.

Are outlets required on every wall? ✔Correct Answer-Residential yes, Commercial no

What is the minimum clear floor space in front of a lavatory? ✔Correct Answer-30" x 48" with
about 17" of that clear under the lavatory

What is the minimum clear floor space in front of a bathtub? ✔Correct Answer-30" x 48"

What is the minimum clear floor space in front of a urinal? ✔Correct Answer-30" x 48"

What is the minimum clear floor space in front of a shower? ✔Correct Answer-30" x 48"

All front approach (barrier free) counters must have a clear knee space of at least: ✔Correct
Answer-30" W x 17"D

All front approach (barrier free) counters must have a clear floor space of: ✔Correct Answer-30" W
x 48"D with about 17" of the 48" underneath the counter

(t/f) The dip of the overflow shall not be considered in determining knee and toe clearances.
✔Correct Answer-true, you don't count the overflow drain

For the PRAC, this chair is in the way of a credenza. Where do I put the marker(s)? ✔Correct
Answer-On BOTH the chair AND the credenza, they are in the way of each other.

What are the CLEARANCES required at an accessible toilet/water closet? ✔Correct Answer-a 60"
turnaround anywhere in the space, have 60" clear at the toilet's rear wall, and 56" clear along the
side wall.

When taking PRAC, are clearances and dimensions the same? ✔Correct Answer-NO - clearances
are the dashed shaped boxes and dimensions are the linear strings

When taking PRAC, can you put more than one room label per room when asked to label spaces per
program? ✔Correct Answer-NO, one label per room. just because you can fit 2 workstations in an
open office, doesn't mean you put the "open office" label in the room twice.

Which walls are subject to the most glare and heat issues? ✔Correct Answer-South

Where should emergency lighting be located? ✔Correct Answer-Aisles, corridors, and exit access
stairways and ramps.

, Where should audio/visual fire alarms be located? ✔Correct Answer-Restrooms, hallways, lobbies,
and general assembly areas & visible from any location in the room. This means that sometimes 2
are required if the space is a hallway with a turn. They are mounted between 6'-8" to 7'-6" AFF.

what do supply diffusers look like in an RCP ✔Correct Answer-They typically have an X through
them

what do return diffusers typically look like in an RCP? ✔Correct Answer-They typically have a
diagonal line through them.

What residential walls need to be framed as plumbing walls? ✔Correct Answer-Any wall with any
type of plumbing going through it. Standard residential walls are 2x4 studs and walls with any pipes
going through need to be 2x6.

What residential appliances require a 240V outlet? ✔Correct Answer-Appliances with a heating
element like ovens, cooktops and dryers.

How should outlets be placed in a residential kitchen? ✔Correct Answer-Each appliance gets an
outlet. Each section of countertop that is wider than 12" gets an outlet. Outlets shouldn't be closer
than 24". An outlet should be placed on either side of the sink. All outlets in a dwelling serving the
countertop will be GFCI.

Per NCIDQ, electrical receptacles located within ________" of a water source must be _______.
✔Correct Answer-......36" of a water source must be GFI.

Name the correct parts of a door. ✔Correct Answer-1. Head
2. Top Rail
3. Panel
4. Lock Rail
5. Hinge Jamb
6. Strike Jamb
7. Stile
8. Bottom Rail
9. Sill

When would you choose to label the base of a door elevation a Sill rather than a Threshold?
✔Correct Answer-If you cannot see a distinction between the sill and threshold, choose Sill. If there
was a section view showing the actual threshold, then you can label it. Otherwise the base of a door
is a Sill.

Do showers, balconies, and closets count towards the max travel distance? ✔Correct Answer-YES!!

What is the minimum path width of a pass-through kitchen? ✔Correct Answer-40"

If, per the program, a restroom is not accessible, and a questions asks for accessibility requirements,
what should you always keep in mind? ✔Correct Answer-the toilet distance from the nearest
adjacent wall.

What is non-accessible counter height? ✔Correct Answer-36"

Document information

Uploaded on
March 29, 2026
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuvia2026
2.3
(3)
Sold
26
Followers
1
Items
6351
Last sold
2 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions