DSA Exam updated and verified questions, answers, and solutions. Trenches parallel to footings shall not be below a plane having a downward 1:2 slope starting ________________" above the bottom of the footing, and not closer than _____________". - Answer- 9 18 1809A.14 An expansion index greater than ____________ is a characteristic of expansive soil? - Answer- 20 1803A.5.3 What is the minimum slump for deep foundation pours? - Answer- 4" 1808A.8.1 What is the max slope of a stepped footing? - Answer- 1:2 1809A.3 Where pipes pass through footings, pipe sleeves shall provide a minimum of _________________" clearance all around? - Answer- 1 1809A.14 When testing identified reinforcing bars with mill certs, 1 tensile and bend test shall be done per ____________ tons of rebar size? - Answer- 10 1913A.2 When testing post installed anchors, the test frequency for non structural anchors should be _______________% - Answer- 50 1905A.5 What is the minimum reinforcement requirements at intersections of walls with floors, columns, and footing? - Answer- #4 @ 12" o.c. for each layer of wall reinforcement 1905A.1.8 What is the minimum psi for shotcrete? - Answer- 4,000 1910A.1 When should rebar lap splices and developmental lengths be increased? - Answer- 1. Closely spaced parallel bars 2. Tight edge distance 3. More than 12" concrete cast below bar (increase 1.3) 4. Lightweight aggregate (ACI 318 12.14.2) written in When are "hook type" (J hook) anchor sill bolts acceptable? - Answer- Interior, non-shear walls (ACI 318 Appendix D2 written in) When is waiver of continuous batch plant allowed? - Answer- 1. Batch plant certification acceptable to DSA 2. Single story light framed buildings and isolated equipment foundations where deep foundations are not used (1705A.3.3.1) Project construction documents typically require _________________% max moisture content of wood at fabrication - Answer- 19% (2303.1.8.2) During wood construction, what is considered fabrication? - Answer- Fastener installation (2303.1.8.2) Why is 19% max moisture content required during fabrication? - Answer- Bolts values reduced up to 60% and nails 75% (NDS Table 11.3.3) Each glulam member must be market by whom? - Answer- Manufacturer Special inspector (1705A.5.4) What items of a wood structural panel shall be verified? - Answer- Grade Thickness Span Rating Exposure Rating Sill plates should be made from what type of wood u.n.o? - Answer- Preservative-treated (PT) Douglas Fir. Fasteners, nuts, and washers at preservative treated & fire retardant treated wood shall be what type? - Answer- Hot-dipped, zinc-coated galvanized steel, stainless steel, silicon bronze or copper. (2304.9.5.1) What is the minimum clearance from grade for wood supported by exterior foundation walls? - Answer- 8" minimum (2304.11.2.2) What is the minimum clearance from grade between wood and slab on grade at shower or toilet rooms with more than 2 plumbing fixtures? - Answer- 6" minimum (2304.11.2.4.1) For foundation anchor bolts, 3x3x.229" plate washers are required to extend within ____________" max of edge of sill plate on the sheathed side. - Answer- 1/2" SDPWS 4.3.6.4.3 For foundation anchor bolts, is a standard cut washer is also required when plate washer has a slotted hole? - Answer- Yes SDPWS 4.3.6.4.3 What is the max slot for a slotted washer at a foundation anchor bolt? - Answer- 1 3/4" SDPWS 4.3.6.4.3 What is the length of a 8d common nail? - Answer- 2-1/2" (Appendix A of SDPWS) Do all holes and notches in wood need to be detailed on DSA approved drawings? - Answer- Yes (Slide 60) What needs to be done when nails tend to split wood? - Answer- Pre-bore (NDS 11.1.6.3) Holes for bolts shall be a minimum of ________ to a maximum of ___________ larger than the bolt diameter? - Answer- 1/32" - 1/16" (NDS 11.1.3.2) The clearance hole for the shank of a lag screw shall be what size? - Answer- Same diameter as the shank diameter. (11.1.4) The pre-drilled hole for the threaded part of lag screw going into wood with G0.5, shall be drilled at _____________% to ______________% shank diameter? - Answer- 40 to 70 (11.1.4) 3/16" weep holes at ______________" max spacing are required for all masonry veneer? - Answer- 33 TMS 402 6.1.6.2 What type of nails should be used on tile roofing? - Answer- Copper, brass, or stainless steel CBC 1507.3.7 Moveable equipment must be anchored if ______________________? - Answer- Permanently attached to building utility services (elec, gas, water) 1616A.1.18 Power actuated fasteners can be used in steel when the load on the fastener is less than or equal to _____________________lbs? - Answer- 250 (1616A) How many safety wires are required for a suspended light fixture that weighs 40 lbs? - Answer- 2-#12 wires (1616A.1.20) How many turns are required for a splay (bracing) wire? - Answer- 4 tight turns wishing 1-1/2" (1616A.1.20)

Content preview

DSA Exam updated and verified
questions, answers, and solutions.
Trenches parallel to footings shall not be below a plane having a downward 1:2 slope
starting ________________" above the bottom of the footing, and not closer than
_____________". - Answer- 9
18
1809A.14

An expansion index greater than ____________ is a characteristic of expansive soil? -
Answer- 20
1803A.5.3

What is the minimum slump for deep foundation pours? - Answer- 4"
1808A.8.1

What is the max slope of a stepped footing? - Answer- 1:2
1809A.3

Where pipes pass through footings, pipe sleeves shall provide a minimum of
_________________" clearance all around? - Answer- 1
1809A.14

When testing identified reinforcing bars with mill certs, 1 tensile and bend test shall be
done per ____________ tons of rebar size? - Answer- 10
1913A.2

When testing post installed anchors, the test frequency for non structural anchors
should be _______________% - Answer- 50
1905A.5

What is the minimum reinforcement requirements at intersections of walls with floors,
columns, and footing? - Answer- #4 @ 12" o.c. for each layer of wall reinforcement
1905A.1.8

What is the minimum psi for shotcrete? - Answer- 4,000
1910A.1

When should rebar lap splices and developmental lengths be increased? - Answer- 1.
Closely spaced parallel bars
2. Tight edge distance
3. More than 12" concrete cast below bar (increase 1.3)
4. Lightweight aggregate
(ACI 318 12.14.2) written in

, When are "hook type" (J hook) anchor sill bolts acceptable? - Answer- Interior, non-
shear walls
(ACI 318 Appendix D2 written in)

When is waiver of continuous batch plant allowed? - Answer- 1. Batch plant certification
acceptable to DSA
2. Single story light framed buildings and isolated equipment foundations where deep
foundations are not used
(1705A.3.3.1)

Project construction documents typically require _________________% max moisture
content of wood at fabrication - Answer- 19%
(2303.1.8.2)

During wood construction, what is considered fabrication? - Answer- Fastener
installation
(2303.1.8.2)

Why is 19% max moisture content required during fabrication? - Answer- Bolts values
reduced up to 60% and nails 75%
(NDS Table 11.3.3)

Each glulam member must be market by whom? - Answer- Manufacturer
Special inspector
(1705A.5.4)

What items of a wood structural panel shall be verified? - Answer- Grade
Thickness
Span Rating
Exposure Rating

Sill plates should be made from what type of wood u.n.o? - Answer- Preservative-
treated (PT) Douglas Fir.

Fasteners, nuts, and washers at preservative treated & fire retardant treated wood shall
be what type? - Answer- Hot-dipped, zinc-coated galvanized steel, stainless steel,
silicon bronze or copper.
(2304.9.5.1)

What is the minimum clearance from grade for wood supported by exterior foundation
walls? - Answer- 8" minimum
(2304.11.2.2)

What is the minimum clearance from grade between wood and slab on grade at shower
or toilet rooms with more than 2 plumbing fixtures? - Answer- 6" minimum

Document information

Uploaded on
March 27, 2026
Number of pages
15
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ScholarExams
3.8
(74)
Sold
398
Followers
186
Items
11413
Last sold
8 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions