1. A ground source heat pump system primarily transfers heat by
circulating a fluid through which component to exchange thermal
energy with the ground?
A. Compressor
B. Ground loop
C. Expansion valve
D. Air handler

The ground loop is the primary component where the circulating fluid
exchanges heat with the earth’s stable temperatures.

2. Which type of ground loop configuration typically requires the least
amount of land area?
A. Vertical closed-loop
B. Horizontal closed-loop
C. Pond or lake loop
D. Open loop

,Horizontal loops are installed in trenches close to the surface and generally
occupy the least vertical space, though they require more land area
horizontally.

3. What is the primary purpose of a desuperheater in a ground source
heat pump system?
A. Increase loop fluid pressure
B. Reduce refrigerant superheat
C. Provide domestic hot water heating
D. Expand refrigerant

A desuperheater captures excess heat from the refrigerant to heat potable
water, improving overall system efficiency.

4. In a closed-loop ground source system, the circulating fluid commonly
used is:
A. Pure water only
B. Propane
C. Ethanol
D. Water mixed with antifreeze

Water mixed with antifreeze is used to prevent freezing in cold climates
while transferring heat effectively.

5. During installation, loop field spacing is critical to prevent thermal
interference. If loops are spaced too closely, the system will:
A. Increase heat transfer efficiency
B. Reduce overall heat exchange capacity
C. Improve antifreeze performance
D. Require smaller pumps

Closely spaced loops cause heat to build up in the ground, reducing the
effective capacity for heat exchange and lowering system performance.

6. What instrument is used to measure fluid temperature in a ground
loop?
A. Manometer

, B. Thermometer or temperature sensor
C. Anemometer
D. Hygrometer

Temperature sensors or thermometers measure fluid temperatures to
ensure the loop is operating within design parameters.

7. If a ground source heat pump is undersized for a building’s heat load,
the system will:
A. Run continuously and fail to maintain setpoint temperatures
B. Cycle on and off frequently
C. Provide excessive dehumidification
D. Reduce loop circulating pressure

An undersized system cannot meet demand, causing long runtimes without
reaching desired indoor conditions.

8. The coefficient of performance (COP) of a heat pump is defined as:
A. Heat output divided by heat loss
B. Heat delivered divided by electrical energy consumed
C. Electrical energy input divided by heat removed
D. Loop fluid temperature difference

COP quantifies system efficiency by comparing useful heat delivered to the
electrical energy consumed.

9. In an open-loop ground source system, water is extracted from:
A. The building’s water heater
B. The municipal supply only
C. A well or surface water source
D. A municipal sewage line

Open-loop systems use groundwater or surface water as the heat
exchange medium, which is then discharged appropriately.

10. Which refrigerant property is critical for ground source heat
pump performance?

Document information

Uploaded on
March 10, 2026
Number of pages
26
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$22.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PrepPal1
4.0
(25)
Sold
105
Followers
6
Items
4534
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions