Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Maine State Journeyman Exam up to 15gph Questions With Verified Answers

Rating
-
Sold
-
Pages
13
Grade
A+
Uploaded on
09-03-2026
Written in
2025/2026

Maine State Journeyman Exam up to 15gph Questions With Verified Answers .How many apprentices can a journeyman directly supervise? - ANSWERS-2 .When performing any service work on a customers heating system the licensee must notify the homeowner of? - ANSWERS-Efficiency and code violations .Can a licensed journeyman perform a cleaning on wood/oil combination unit without direct supervision? - ANSWERS-No .When installing a furnace, direct wired water heater or boiler what must be done prior to placing it in service? - ANSWERS-Everything complies with NFPA 31 code .When installing a new oil burner the _______ must be brought into compliance with the rules of the board before ______? - ANSWERS-Wiring Start up .When an emergency situation arises that does not allow adequate time to get the chimney lined/repaired before installing the new heating appliance what can be done? - ANSWERS-90 day waiver .Who is responsible for ensuring repairs or the chimney is lined within the 90 days? - ANSWERS-InstallerLicensee .When is a heat loss required? - ANSWERS-For new install .Prior to a boiler replacement a________ or a ________ Must be conducted before replacement of an existing system. - ANSWERS-Heat loss/ heat load .The low-water cut off must be located where? - ANSWERS-6 inches above boiler crown sheet but in no case below .An oil supply or return line under cement subfloor or earth must be ________ And without ________? - ANSWERS-Sleeved Fittings (continuous) .Coated copper tubing must have _______ Installed at the tank when ________? - ANSWERS-OSV Underground .Whenever an outlet of an oil supply tank is located more than ______ above the burner a _____ or _____ valve is required. - ANSWERS-4ft OSV or PRV .Unprotected lines that are buried or grouted must be? - ANSWERS-removed from service .All fuel supply tanks must be a minimum of _____ From any gas and or solid fuel burning appliance - ANSWERS-5ft .If a customer is converting to an alternative fuel and leaving the oil tank what must be done? - ANSWERS-Vent pipe left in place fill pipe removed and plugged supply lines removed and plugged .Outside oil tank supports shall not be _______? - ANSWERS-Wood .What is the required thickness of the vertical oil tank pad? - ANSWERS-3 inches of solid concrete .When are shims allowed to be used on oil tank legs? - ANSWERS-Never .Oil tanks must be disposed of in accordance with? - ANSWERS-DEP .What are two options for supporting in inside oil tank on unfinished floors? - ANSWERS-3" Cement padssolid concrete blocks .When are vent alarms required on inside oil tanks? - ANSWERS-Always on all tanks 11-5,000 gals .If the entrance to the boiler room is only accessible from the outside the ____________ may be placed _________? - ANSWERS-Emergency switch. At the inside not more than 1 foot away from the door

Show more Read less
Institution
Journeyman Oil Burners Maine
Course
Journeyman oil burners maine

Content preview

Maine State Journeyman Exam up to
15gph Questions With Verified
Answers



\.How many apprentices can a journeyman directly supervise? - ANSWERS✔-2


\.When performing any service work on a customers heating system the licensee
must notify the homeowner of? - ANSWERS✔-Efficiency and code violations


\.Can a licensed journeyman perform a cleaning on wood/oil combination unit
without direct supervision? - ANSWERS✔-No


\.When installing a furnace, direct wired water heater or boiler what must be
done prior to placing it in service? - ANSWERS✔-Everything complies with NFPA
31 code


\.When installing a new oil burner the _______ must be brought into compliance
with the rules of the board before ______? - ANSWERS✔-Wiring Start up


\.When an emergency situation arises that does not allow adequate time to get
the chimney lined/repaired before installing the new heating appliance what can
be done? - ANSWERS✔-90 day waiver

, \.Who is responsible for ensuring repairs or the chimney is lined within the 90
days? - ANSWERS✔-Installer\Licensee



\.When is a heat loss required? - ANSWERS✔-For new install


\.Prior to a boiler replacement a________ or a ________ Must be conducted
before replacement of an existing system. - ANSWERS✔-Heat loss/ heat load



\.The low-water cut off must be located where? - ANSWERS✔-6 inches above
boiler crown sheet but in no case below


\.An oil supply or return line under cement subfloor or earth must be ________
And without ________? - ANSWERS✔-Sleeved Fittings (continuous)


\.Coated copper tubing must have _______ Installed at the tank when ________?
- ANSWERS✔-OSV Underground


\.Whenever an outlet of an oil supply tank is located more than ______ above the
burner a _____ or _____ valve is required. - ANSWERS✔-4ft OSV or PRV



\.Unprotected lines that are buried or grouted must be? - ANSWERS✔-removed
from service


\.All fuel supply tanks must be a minimum of _____ From any gas and or solid fuel
burning appliance - ANSWERS✔-5ft

Written for

Institution
Journeyman oil burners maine
Course
Journeyman oil burners maine

Document information

Uploaded on
March 9, 2026
Number of pages
13
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
Journeyman Oil Burner Exam Bundle
-
11 2026
$ 55.53 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
IszackBd University Of Washington
View profile
Follow You need to be logged in order to follow users or courses
Sold
39
Member since
1 year
Number of followers
3
Documents
5564
Last sold
1 week ago
IszackBd Stuvia

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don\'t find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. FOR ANY REQUEST FEEL FREE TO REACH US

Read more Read less
5.0

3 reviews

5
3
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions