What is Chapter 1 in NFPA 72 - ANSWER Administration
What is Chapter 2 in NFPA 72 - ANSWER Referenced Publications
What is Chapter 3 in NFPA 72 - ANSWER Definitions
What are Chapter 4, 5 and 6 in NFPA 72 - ANSWER Reserved
What is Chapter 7 in NFPA 72 - ANSWER Documentation
What are Chapters 8 and 9 in NFPA 72 - ANSWER Reserved
What is Chapter 10 in NFPA 72 - ANSWER Fundamentals
What is Chapter 11 in NFPA 72 - ANSWER Reserved
What is Chapter 12 in NFPA 72 - ANSWER Circuits and Pathways
What is Chapter 13 in NFPA 72 - ANSWER Reserved
What is Chapter 14 in NFPA 72 - ANSWER Inspection, Testing, and Maintenance
1
,What are Chapters 15 and 16 in NFPA 72 - ANSWER Reserved
What is Chapter 17 in NFPA 72 - ANSWER Initiating Devices
What is Chapter 18 in NFPA 72 - ANSWER Notification Appliances
What are Chapters 19 and 20 in NFPA 72 - ANSWER Reserved
What is Chapter 21 in NFPA 72 - ANSWER Emergency Control Function Interfaces
What is Chapter 22 in NFPA 72 - ANSWER Reserved
What is Chapter 23 in NFPA 72 - ANSWER Protected Premises Fire Alarm Systems
What is Chapter 24 in NFPA 72 - ANSWER Emergency Communications Systems (ECS)
What is Chapter 25 in NFPA 72 - ANSWER Reserved
What is Chapter 26 in NFPA 72 - ANSWER Supervising Station Alarm Systems
What is Chapter 27 in NFPA 72 - ANSWER Public Emergency Alarm Reporting Systems
What is Chapter 28 in NFPA 72 - ANSWER Reserved
What is Chapter 29 in NFPA 72 - ANSWER Single- and Multiple-Station Alarms and House-
hold Fire Alarm Systems
2
, Article 760 of NFPA 70 Provides requirements of _________. - ANSWER Fire Alarm Sys-
tems
(NFPA 70, Article 760, Pg.646)
Inside a FACU, what is the minimum separation between 110V AC lines and the power lim-
ited wires? - ANSWER 0.25"
(NFPA 70, Article 760.136)
What is the standard length of E.M.T. conduit? - ANSWER 10'
Open grounds result in a(n) _______signal. - ANSWER Trouble
(NFPA 72, Article 10.17.3, Pg.72)
A manual fire alarm box ( A.K.A. pull station), when actuated, will produce a(n) ____ signal. -
ANSWER Alarm
Upon detection of a trouble condition, fire alarm system controls must initiate a trouble sig-
nal within ___ seconds. - ANSWER 200
(NFPA 72, Article 10.15.1, Pg.71)
Secondary power supplies must supply power to an in-building fire emergency voice/alarm
communications fire alarm system for a minimum of _____. - ANSWER 24 hours of
standby followed by 15 Minutes of alarm
(NFPA 72, Article 10.6.7.2.1, Pg.67)
Waterflow switches are permitted to have a time delay, or retard, up to __. - ANSWER 90
seconds
(NFPA 72, Article 17.12.2, Pg.105)
3
What is Chapter 2 in NFPA 72 - ANSWER Referenced Publications
What is Chapter 3 in NFPA 72 - ANSWER Definitions
What are Chapter 4, 5 and 6 in NFPA 72 - ANSWER Reserved
What is Chapter 7 in NFPA 72 - ANSWER Documentation
What are Chapters 8 and 9 in NFPA 72 - ANSWER Reserved
What is Chapter 10 in NFPA 72 - ANSWER Fundamentals
What is Chapter 11 in NFPA 72 - ANSWER Reserved
What is Chapter 12 in NFPA 72 - ANSWER Circuits and Pathways
What is Chapter 13 in NFPA 72 - ANSWER Reserved
What is Chapter 14 in NFPA 72 - ANSWER Inspection, Testing, and Maintenance
1
,What are Chapters 15 and 16 in NFPA 72 - ANSWER Reserved
What is Chapter 17 in NFPA 72 - ANSWER Initiating Devices
What is Chapter 18 in NFPA 72 - ANSWER Notification Appliances
What are Chapters 19 and 20 in NFPA 72 - ANSWER Reserved
What is Chapter 21 in NFPA 72 - ANSWER Emergency Control Function Interfaces
What is Chapter 22 in NFPA 72 - ANSWER Reserved
What is Chapter 23 in NFPA 72 - ANSWER Protected Premises Fire Alarm Systems
What is Chapter 24 in NFPA 72 - ANSWER Emergency Communications Systems (ECS)
What is Chapter 25 in NFPA 72 - ANSWER Reserved
What is Chapter 26 in NFPA 72 - ANSWER Supervising Station Alarm Systems
What is Chapter 27 in NFPA 72 - ANSWER Public Emergency Alarm Reporting Systems
What is Chapter 28 in NFPA 72 - ANSWER Reserved
What is Chapter 29 in NFPA 72 - ANSWER Single- and Multiple-Station Alarms and House-
hold Fire Alarm Systems
2
, Article 760 of NFPA 70 Provides requirements of _________. - ANSWER Fire Alarm Sys-
tems
(NFPA 70, Article 760, Pg.646)
Inside a FACU, what is the minimum separation between 110V AC lines and the power lim-
ited wires? - ANSWER 0.25"
(NFPA 70, Article 760.136)
What is the standard length of E.M.T. conduit? - ANSWER 10'
Open grounds result in a(n) _______signal. - ANSWER Trouble
(NFPA 72, Article 10.17.3, Pg.72)
A manual fire alarm box ( A.K.A. pull station), when actuated, will produce a(n) ____ signal. -
ANSWER Alarm
Upon detection of a trouble condition, fire alarm system controls must initiate a trouble sig-
nal within ___ seconds. - ANSWER 200
(NFPA 72, Article 10.15.1, Pg.71)
Secondary power supplies must supply power to an in-building fire emergency voice/alarm
communications fire alarm system for a minimum of _____. - ANSWER 24 hours of
standby followed by 15 Minutes of alarm
(NFPA 72, Article 10.6.7.2.1, Pg.67)
Waterflow switches are permitted to have a time delay, or retard, up to __. - ANSWER 90
seconds
(NFPA 72, Article 17.12.2, Pg.105)