Arizona Contractor License CR-67 Exam Questions with Correct Verified Answers | Latest Update 2026/2027 | Graded A+ | 100% Assured Pass. A service disconnect need to have a rating which is? --- correct answer ---No less than that the calculated load or for the type of installation Fast- blow fuses tend to open real quick when the rated current is reached. --- correct answer ---True System grounding is required when you have a supply transformer of a SOV or lower system? --- correct answer ---System grounding is required when you have a supply transformer of a 50V or lower system which itself is supplied from a source over 150V to the ground On a class 1 circuit it is ok to use smaller wire sizes than normal power circuits such as. -- - correct answer ---Anything 16 AWG or lower Class 1 signaling and remote control circuits are limited too? --- correct answer ---600 Volts When a circuit controls equipment can introduce a direct life safety hazard, the circuit has to be? --- correct answer ---Class 1 Class 2 circuit must be kept separate from lighting? --- correct answer ---True Generally, cables that are installed in ducts for environment air should be of what type? - -- correct answer ---CL2P or CL3P The pulling tension in pounds for a copper wire should not exceed how many times the circular mil area of a conductor? --- correct answer ---.008 mil The breaking capacity specifies. --- correct answer ---maximum current the fuse can handle _____ occurs when there are two points in the circuit accidentally coming in contact. --- correct answer ---Short circuit Circuits of 30A may be used to serve fixed lighting units with heavyduty Iampholders in non-dwellings units. --- correct answer ---True Circuits of 40A may be used to serve fixed lighting with heavy-duty Iampholders in fixed cooking appliances. --- correct answer ---True

Content preview

Arizona Contractor License CR-67 Exam Questions with
Correct Verified Answers | Latest Update 2026/2027 |
Graded A+ | 100% Assured Pass.


A service disconnect need to have a rating which is? --- correct answer ---No less than
that the calculated load or for the type of installation



Fast- blow fuses tend to open real quick when the rated current is reached. --- correct
answer ---True



System grounding is required when you have a supply transformer of a SOV or lower
system? --- correct answer ---System grounding is required when you have a supply
transformer of a 50V or lower system which itself is supplied from a source over 150V to
the ground



On a class 1 circuit it is ok to use smaller wire sizes than normal power circuits such as. --
- correct answer ---Anything 16 AWG or lower



Class 1 signaling and remote control circuits are limited too? --- correct answer ---600
Volts

,When a circuit controls equipment can introduce a direct life safety hazard, the circuit
has to be? --- correct answer ---Class 1



Class 2 circuit must be kept separate from lighting? --- correct answer ---True



Generally, cables that are installed in ducts for environment air should be of what type? -
-- correct answer ---CL2P or CL3P




The pulling tension in pounds for a copper wire should not exceed how many times the
circular mil area of a conductor? --- correct answer ---.008 mil



The breaking capacity specifies. --- correct answer ---maximum current the fuse can
handle



_____ occurs when there are two points in the circuit accidentally coming in contact. ---
correct answer ---Short circuit



Circuits of 30A may be used to serve fixed lighting units with heavyduty Iampholders in
non-dwellings units. --- correct answer ---True

, Circuits of 40A may be used to serve fixed lighting with heavy-duty
Iampholders in fixed cooking appliances. --- correct answer ---True



Cables installed in building locations other than in plenums for environmental air may
be? --- correct answer ---CL2 or CL3



Voltage drop can be calculated based on? --- correct answer ---Voltage drop = (2) x (the
circuit length in ft) x (resistance per 1 ft) x (current)



Class 2 circuits. --- correct answer ---Class 2 circuits may not be derived from a large
transformer by using fuses.



You need to have at least how many wall switch- controlled lighting outlets installed in
every habitable room? --- correct answer ---Need at least 1



A lighting system that has an isolating power supply operating at no more than _____
volts peak under any load condition is considered as low voltage --- correct answer ---30
Volts




FPL cables may be used for general purpose alarms without conduit. Exception include. -
-- correct answer ---Riser, Duct, and plenum applications

Document information

Uploaded on
March 4, 2026
Number of pages
28
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ExcelAcademia2026
3.7
(390)
Sold
2292
Followers
1650
Items
9011
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions