A three dimensional fire often involves static flammable liquid.
true or false - ANSWER false. 3D firess unvolve flammable liquid
in motion as well as both horizontal and vertical surfaces.
Class A fire extinguisher - ANSWER are ok for wood, paper,
some plastics and textiles. They offer the coating effects of dry
chemicals.
Dry chemical stored pressure fire extinguishers: - ANSWER
should be removed or replaced at their next 6 year
maintenance or hydrostatic test interval.
B:C - ANSWER Talking about UL rating, the _____ rating refers to
the amount of sq footage an extinguisher covers
Class B fire extinguishers cannot handle flammable liquid -
ANSWER False
,2|Page
employees must be trained in proper use of all portable fire
extinguishers according to - ANSWER CRF29
monthly - ANSWER you need to have portable fire extinguishers
VISUALLY inspected at least _____ according to 29 CFR
1910.157 (e) (2)
Class A/B fire extinguishers - ANSWER should NOT be used
forfire that involves live electrical equipment
annually - ANSWER Water or steam fire extinguishers need to
be discharged, dissassembled and inspected at least:
3.5 ft - ANSWER An extinguisher weighing over 40 lbs should be
installed so the top is no more than __ from the ground
50 ft. - ANSWER OSHA specified maximum travel distance to an
extinguisher for Class B
, 3|Page
6 yrs - ANSWER dry chem extinguishers requiring 12 yr
hydrostatic test must be emptied for maintenance procedures
every
A rated UL extinguishers = how many gallons of water? -
ANSWER 1.25
C - ANSWER Class ____ fire extinguishers use electrically
nonconductive extinguishing agents
Every 5 years - ANSWER Cartridge operated water based
portable extinguishers need hydrostatic testing
stored pressure type extinguishers need need INTERNAL
examination : - ANSWER never
5 ft above the ground - ANSWER extinguishers weighing 40 lbs
or less must be installed so top of canister is no more than
_____
Texas Ext Type B TFM02 Questions and Answers with 100%
Complete Solutions
A three dimensional fire often involves static flammable liquid.
true or false - ANSWER false. 3D firess unvolve flammable liquid
in motion as well as both horizontal and vertical surfaces.
Class A fire extinguisher - ANSWER are ok for wood, paper,
some plastics and textiles. They offer the coating effects of dry
chemicals.
Dry chemical stored pressure fire extinguishers: - ANSWER
should be removed or replaced at their next 6 year
maintenance or hydrostatic test interval.
B:C - ANSWER Talking about UL rating, the _____ rating refers to
the amount of sq footage an extinguisher covers
Class B fire extinguishers cannot handle flammable liquid -
ANSWER False
,2|Page
employees must be trained in proper use of all portable fire
extinguishers according to - ANSWER CRF29
monthly - ANSWER you need to have portable fire extinguishers
VISUALLY inspected at least _____ according to 29 CFR
1910.157 (e) (2)
Class A/B fire extinguishers - ANSWER should NOT be used
forfire that involves live electrical equipment
annually - ANSWER Water or steam fire extinguishers need to
be discharged, dissassembled and inspected at least:
3.5 ft - ANSWER An extinguisher weighing over 40 lbs should be
installed so the top is no more than __ from the ground
50 ft. - ANSWER OSHA specified maximum travel distance to an
extinguisher for Class B
, 3|Page
6 yrs - ANSWER dry chem extinguishers requiring 12 yr
hydrostatic test must be emptied for maintenance procedures
every
A rated UL extinguishers = how many gallons of water? -
ANSWER 1.25
C - ANSWER Class ____ fire extinguishers use electrically
nonconductive extinguishing agents
Every 5 years - ANSWER Cartridge operated water based
portable extinguishers need hydrostatic testing
stored pressure type extinguishers need need INTERNAL
examination : - ANSWER never
5 ft above the ground - ANSWER extinguishers weighing 40 lbs
or less must be installed so top of canister is no more than
_____