OIL BURNER LICENSE FINAL EXAM QUESTIONS WITH CORRECT DETAILED ANSWERS || ALREADY GRADED A+ RECENT VERSION What is the first thing a tech should do when arriving at a no combustion call? - ANSWER️Ask how many times the customer reset the unit. What is the best long-term solution for preventing a clogged nozzle? - ANSWER️-Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - ANSWER️False When in the presence of a flame, a cad cell normally reads. - ANSWER️300-1000 ohms If a pump is used to bring oil to a level higher than the tank, an oil safety valve is required. - ANSWER️True On a call where a hydronic heat system is putting out too much heat on the stack, the issue may be. - ANSWER️-Too much draft. -Not enough combustion air in the equipment room. -Air leakage into chamber. A high CO2 reading is caused by. - ANSWER️Incomplete combustion An often-overlooked cause of a high CO2 reading is. - ANSWER️Not enough combustion air in the equipment room. When multiple pumps are wired together in a heating system, they should be wired in. - ANSWER️parallel In a series circuit. - ANSWER️Current has one path. When 2 burners are connected to the same chimney. - ANSWER️Sufficient draft must be obtained to operate both units. The ignition transformer is located. - ANSWER️In the primary control. When safeties are wired in series one safety will affect the operation of the others. - ANSWER️True A stack switch is no longer allowed to be installed or replaced because. - ANSWER️It is safety cutout time is higher than what is now required. What is a power venter and what does it do? - ANSWER️An electrical device that sends fluid gases into the chimney connector. A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent opening for combustion air? - ANSWER️140" The difference between an adjustable flame retention burner and a fixed flame retention burner is? - ANSWER️Air inlets can be adjusted Ignitor position can be adjusted Fuel can be adjusted Oil tank design, construction, installation and testing shall be in accordance with. - ANSWER️527 CMR 9.0 Heat is a form of. - ANSWER️Energy If a burner is operational but the circulator pump isn't running. - ANSWER️The pump relay is not working correctly A method of dealing with low viscosity/cold temps with #2 oil? - ANSWER️Increase pump pressure/ decrease nozzle size What is needed at the outlet of an oil tank? - ANSWER️Thermal safety valve Where do you obtain an installation permit for oil burners? - ANSWER️Fire Dept How many Btu's approximately in 1 gal of #2 fuel oil? - ANSWER️140,000 btu's Solid state ignition is superior to spark because - ANSWER️It is not affected by reduced voltage What is an installation? - ANSWER️The complete setting in place, ready for operation, of an oil burner appliance together with its accessories and equipment. How far must a power vent terminate from an opening or window? - ANSWER️4' A pump in a one pipe system that is full of air can be self-purged. - ANSWER️False List the minimum size of an oil supply line. - ANSWER️3/8" A material with electrons so loose it allows voltage to pass with little or no resistance. - ANSWER️Is a conductor

Content preview

OIL BURNER LICENSE FINAL EXAM
QUESTIONS WITH CORRECT DETAILED
ANSWERS || ALREADY GRADED A+
<RECENT VERSION>


What is the first thing a tech should do when arriving at a no combustion call? -
ANSWER Ask how many times the customer reset the unit.


What is the best long-term solution for preventing a clogged nozzle? -
ANSWER -Remove any underground storage tanks.
-Install a quality oil filter.
-Cut the suction line 10" above the tank outlet to prevent sludge.


Hot water and steam valves are interchangeable. - ANSWER False



When in the presence of a flame, a cad cell normally reads. - ANSWER 300-
1000 ohms


If a pump is used to bring oil to a level higher than the tank, an oil safety valve is
required. - ANSWER True

, On a call where a hydronic heat system is putting out too much heat on the stack,
the issue may be. - ANSWER -Too much draft.
-Not enough combustion air in the equipment room.
-Air leakage into chamber.


A high CO2 reading is caused by. - ANSWER Incomplete combustion



An often-overlooked cause of a high CO2 reading is. - ANSWER Not enough
combustion air in the equipment room.


When multiple pumps are wired together in a heating system, they should be
wired in. - ANSWER parallel



In a series circuit. - ANSWER Current has one path.



When 2 burners are connected to the same chimney. - ANSWER Sufficient
draft must be obtained to operate both units.


The ignition transformer is located. - ANSWER In the primary control.


When safeties are wired in series one safety will affect the operation of the others.
- ANSWER True


A stack switch is no longer allowed to be installed or replaced because. -
ANSWER It is safety cutout time is higher than what is now required.

, What is a power venter and what does it do? - ANSWER An electrical device
that sends fluid gases into the chimney connector.


A burner in a confined space using 1 GPH of #2 fuel oil requires what size
permanent opening for combustion air? - ANSWER 140"


The difference between an adjustable flame retention burner and a fixed flame
retention burner is? - ANSWER Air inlets can be adjusted


Ignitor position can be adjusted


Fuel can be adjusted


Oil tank design, construction, installation and testing shall be in accordance with. -
ANSWER 527 CMR 9.0



Heat is a form of. - ANSWER Energy


If a burner is operational but the circulator pump isn't running. - ANSWER The
pump relay is not working correctly


A method of dealing with low viscosity/cold temps with #2 oil? -
ANSWER Increase pump pressure/ decrease nozzle size

, What is needed at the outlet of an oil tank? - ANSWER Thermal safety valve


Where do you obtain an installation permit for oil burners? - ANSWER Fire
Dept


How many Btu's approximately in 1 gal of #2 fuel oil? - ANSWER 140,000
btu's


Solid state ignition is superior to spark because - ANSWER It is not affected by
reduced voltage


What is an installation? - ANSWER The complete setting in place, ready for
operation, of an oil burner appliance together with its accessories and equipment.


How far must a power vent terminate from an opening or window? -
ANSWER 4'


A pump in a one pipe system that is full of air can be self-purged. -
ANSWER False



List the minimum size of an oil supply line. - ANSWER 3/8"


A material with electrons so loose it allows voltage to pass with little or no
resistanc. - ANSWER Is a conductor

Document information

Uploaded on
February 22, 2026
Number of pages
68
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
4
Followers
0
Items
141
Last sold
2 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions