Electrode potential is described by this equatio - ANSWER ✓ Nernst equation
If the potential of a half reaction M+ + e M(s) is E1, the potential E of the new
reaction 2M+ + 2e 2M(s) is - ANSWER ✓ E=E1
An electrode on which the reaction of interest takes place is known as this: -
ANSWER ✓ Indicator electrode
An electrode with a stable potential is known as this: - ANSWER ✓ Reference
electrode
By convention, the electrode potential of a standard hydrogen electrode is
accepted to have this value at 100°C: - ANSWER ✓ 0.0 V
A calomel electrode represents this type of electrode - ANSWER ✓ Reference
electrode
In an electrochemical process, an oxidizing agent undergoes this: - ANSWER ✓
Reduction
This is not one of the functions of salt bridge - ANSWER ✓ Facilitate the flow of
ions
This is the functions of salt bridge - ANSWER ✓ Separate the two half cell
Maintain the electric conductivity
Lower the junction potential
,This chemical is commonly used in salt bridge: - ANSWER ✓ KCl
The gain of electron by a chemical species is known as this - ANSWER ✓
Reduction
Principles of this electrochemical method are utilized in a glucose sensor used by
diabetic patients - ANSWER ✓ Amperometry
This physical quantity is measured in Amperometric analysis - ANSWER ✓
Current
Karl-Fisher titration is used to determine this: - ANSWER ✓ Water
Beer's Law involves procedures that use this optical phenomenon to measure
analyte concentrations: - ANSWER ✓ Absorption
According to wave theory, light represents electromagnetic waves consisting of
electrical and magnetic fields oscillating at this angle with respect to each other: -
ANSWER ✓ 90 degrees
According to dual-property theory, light consists of particles known as this: -
ANSWER ✓ Photons
Visible light covers this range of wavelengths: - ANSWER ✓ 400-800nm
Under this condition, Beer's law can not be used - ANSWER ✓ Concentrated
solution
Beer's law plots are generally done at lambda max, because at this wavelength -
ANSWER ✓ The sensitivity is the greatest
In a mass spectrometric detector, the number of electrons is multiplied by a series
of these devices: - ANSWER ✓ Dynodes
In mass spectrum the x-axis represents - ANSWER ✓ the mass to charge ratio
Among all the ionization methods, the amount of fragmentation generated by
electron ionization is this than chemical ionization: - ANSWER ✓ More
, In electron ionization, high energy electrons with this typical value of energy are
used to ionize the analyte molecules: - ANSWER ✓ 70 eV
In a mass spectrum, the most prominent peak is known as this: - ANSWER ✓ base
peak
This spectrometric method is also known as gas-phase electrophoresis: -
ANSWER ✓ Ion mobility spectrometry
Nitrogen rule - ANSWER ✓ If number on nitrogen in compound is odd then the
molecular ion will be characterized by a nominal mass value that is odd
In gas chromatography, the basis for separation of the components of the volatile
material is the difference in - ANSWER ✓ Partition coefficient
What does the retention factor k describe: - ANSWER ✓ The distribution of an
analyte between the stationary and the mobile phase;
The A term in describing the relationship between column height and flow rate is:
- ANSWER ✓ Eddy diffusion
In Gas-Liquid chromatography, the stationary phase is in this physical state: -
ANSWER ✓ Liquid
In GC, a liquid sample is introduced with the help of this device - ANSWER ✓
Micro syringe
This represents a typical liquid sample volume for injection into a GC system: -
ANSWER ✓ 1 micro liter
During sample injection of GC, this is commonly used for thermally unstable
chemicals: - ANSWER ✓ on-Column injection
During split injection in GC, most of the injected sample goes through this: -
ANSWER ✓ Split vent