Patient care areas of healthcare facilities ____ areas such as business offices,
corridors, lounges, day rooms, or similar areas - ANSWER-Do not include
The patient care area is any portion of the healthcare facility where patients are
intended to be ____or ____. - ANSWER-Examined or treated
Each general care area patient bed location in a healthcare facility must be
provided with four ____ or ____ duplex receptacles - ANSWER-Single or two
A hospital is a building or portion thereof used for medical,
psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more
patients - ANSWER-Four
Where installed to reduce electrical noise for electronic equipment, electrical
continuity of the metal raceways shall not be required and metal raceway can
terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment -
ANSWER-Listed fitting
Feeder and branch circuit conductors within ____ inches of a Ballast shall have
an insulation temperature rating not lower than 90°C (194°F) unless supplying a
,luminaiere marked as suitable for a different insulation temperature -
ANSWER-3 inches
Manufactured wiring systems constructed with type MC cable shall be
supported and secured at intervals not exceeding ____ ft. - ANSWER-6 ft
Where a main bonding jumper or a system bonding jumper is a screw only the
screw shall be identified with a ____ that shall be visible with the screw
installed - ANSWER-Green finish
Plug fuses a 15 amperes and lower rating shall be identified by a ____
configuration of the window, cap, or other prominent part to distinguish them
from fuses of higher ampere rating - ANSWER-Hexagon
The load for household electric clothes dryer's in a dwelling unit(s) shall be
either ____ watts (volt-amperes) or the nameplate rating, which ever is larger,
for each dryer served ? - ANSWER-5000 watts
Service conductors installed as unjacketed multiconductor cable shall have a
minimum clearance of ____ windows that are designed to be opened, doors,
porches, stairs fire escape or similar locations. - ANSWER-3 ft (36 inches)
—— Cartridge fuses of the renewable type shall be permitted to be used only
for replacement in existing installation is where there is no evidence of over-
fusing or tampering. - ANSWER-Class H
Branch circuit conductors within ____inches of the ballast shall have an
insulation temperature rating not lower it 90°C 194°F - ANSWER-3" inches
The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. -
ANSWER-8
,In a dwelling unit which appliance is allowed to have a 24"inch cord with
Attachment ground plug ? - ANSWER-Combination range hood/microwave
oven
Type 3 Surge Protective devices can be installed on the load side of a branch
circuit overcurrent device up to the equipment served.if ____ the type 3 SPD
connection must be a minimum 30'ft of conductor a distance from the service or
separately derived system disconnect - ANSWER-Included in the manufactures
instructions
Which flexible cable is Allowed to be used for electric vehicle charging station
300 Volts ? - ANSWER-EVJ
Type ____ fuse adapters shall be designed so that once inserted in a fuse holder
that cannot be removed - ANSWER-Type S fuse
Service drops Installed over roof shall have a vertical clearance of ____ above
the roof surface, and unless a lesser distance is permitted by and exceptions -
ANSWER-8'ft
Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable,
or similar fittings with conductors of Class 1 or electric light or power
conductors, unless ____. - ANSWER-Separated by barrier
In the critical care areas of health care centers, each patient bed shall be
provided with a minimum of ____ duplex receptacles - ANSWER-3 duplex (6
single)
The equipment system shall supply major electric ____ necessary for patient
care and basic hospital operation - ANSWER-Equipment
, The essential electrical system in a healthcare facility shall be compromised of
the - ANSWER-emergency system and the: equipment system
Locations were flammable anesthetics are employed are class I,Division I
locations that shall extend - ANSWER-upwards to a level 5'ft above the floor
In a healthcare facility receptacles and attachment plugs in a hazardous
(classified) location with an anesthizing area shall be listed for use in class I
group ____ locations - ANSWER-Group C
In anesthetic,areas health care equipment frequently in contact with bodies of
persons shall not exceed ____ volts. - ANSWER-10 Volts
Type ____ is multiconductor cable identified for use as underground service
entrance cable. - ANSWER-Type USE cable
Knife switch rated for more than 1200 Amps at 250Volts or less - ANSWER-
Can be used only as isolating switch, shall not be opened under load
Track lighting with outlets in a bathroom is not allowed because ? - ANSWER-
Track lighting has receptacle
Where internal combustion engines are used as the prime motor, an on site fuel
supply shall be provided with an on premise fuel supply sufficient for not less
than ____ hours full demand operation of the system - ANSWER-6 hours
Fixed in place X-ray equipment properly supplied by a branch circuit rated at
not over ____ amperes shall be permitted to be supplied through a suitable
attachment plug cap and hard service cable cord. - ANSWER-30 Amps