Content preview

Masonry ICC || 100% Errorless Solutions.
Does not provide additional strength, but it does improve mortar plasticity, water retention, water
tightness, and bonding ability. correct answers Lime

What ASTM is the standard spec for masonry cement correct answers ASTM C 91

What ASTM is the standard spec for mortar cement correct answers ASTM C 1329

High strength mortar recommended for use in reinforced masonry below grade or in contact with
the earth, as foundation and retaining walls subject to high lateral or compressive loads;
compressive strength is 2500 psi correct answers Type M mortar

Is medium-strength mortar recommended for general use; compressive strength is 750 psi, more
flexible than S or M, which helps to reduce cracks in the masonry units and wall. correct answers
Type N mortar

Minimum compressive strength of only about 350 psi. Very workable, sometimes used for
repair. Generally limited to interior non-loadbearing applications. correct answers Type O mortar

Medium-high strength mortar for use in masonry where bond and lateral strength are more
important than compressive strength; compressive strength is 1800 psi correct answers Type S
mortar

What ASTM is the standard spec for mortar for unit masonry correct answers ASTM C 270

What are the Two lime types correct answers Type N - normal
Type S - higher early plasticity and higher water retentivity capabilities.

IBC does not consider it an acceptable cement for use in commercial buildings correct answers
Plastic Cement

What ASTM Provides proportioning requirements for three different mortars: cement line,
mortar cement, and masonry cement correct answers ASTM C 270

What type of mortar Is not permitted for use in any SFRS for any SDC correct answers Type O
Mortar

SFRS means correct answers Seismic force resisting systems

SDC correct answers Seismic design category

What types of mortar are permitted in SFRS for SDC, D, E, and F correct answers Mortar type
M & S are permitted

, What types of mortar are permitted in SFRS for SDCA, B, and C correct answers Mortar types
M, S, and N are all permitted

What type of mortar is not permitted for use in any SFRS for any SDC correct answers Type O
mortar is not permitted

What type of mortar is permitted with use in glass unit masonry correct answers Type S or M
mortar can be used with glass unit masonry

Specially manufactured mortar must be used for what type of masonry correct answers AAC
masonry requires specially manufactured mortar in thin horizontal mortar joints

Horizontal mortar joints are called correct answers Bed joints

Vertical mortar joints are correct answers Head joints

Mortar must be used within how long of initially adding water to the mix correct answers It must
be used within 2 1/2 hours of initially adding water to the mix

Can you add more water to mortar mix correct answers Yes, but not after 2 1/2 hours

What does grout do? correct answers 1. Grout binds the masonry unit, mortar, and reinforcement
together to create structural masonry.
2. Provides some sheer, but mainly compressive strength to a wall.
3. Embeds reinforcing steel, which provides additional shear strength.
4. Fills empty spaces and voids.

What uses superplasticizer admixtures (and not just extra water) to make the grout soupy and
fluid enough that it can fill grout spaces without being consolidated by a mechanical vibrator?
correct answers Self-consolidating grout

Slumps for conventional grout and self consolidating grout correct answers Conventional grout
has a slump of 8 to 11 inches
Self consolidating grout has a slump flow between 24 and 30 inches

Grout is typically design for a minimum compressive strength of? correct answers 2000 psi

What is the Standard specification for grout for masonry correct answers ASTM C 476.

For ready-mix grout can the slump be adjusted on-site? correct answers Yes, as long as the
specified slump is maintained, then there is no time limit for using ready-mix grout.

When conventional grout is batched on the jobsite, it must be:: correct answers 1. Batched
mechanically per ASTM C 476
2. Mixed for at least 5 minutes
3. Maintain 8" to 11" slump without aggregate segregation

Document information

Uploaded on
February 20, 2026
Number of pages
13
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.59

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(118)
Sold
810
Followers
438
Items
40067
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions