• Verkeerd document? Gratis ruilen
  • Geschreven door studenten die geslaagd zijn
  • Direct beschikbaar na je betaling
  • Online lezen of als PDF
Verkopen
Kies je studieland
Kies je taal
Document preview thumbnail
Voorbeeld 3 van de 16 pagina's
Tentamen (uitwerkingen)

Ncle Test Questions And Answers All Correct

Document preview thumbnail
Voorbeeld 3 van de 16 pagina's

NCLE TEST QUESTIONS AND ANSWERS ALL CORRECT

Voorbeeld van de inhoud

NCLE TEST QUESTIONS
AND ANSWERS ALL
CORRECT
The FDA has recommended that extended wear contact lenses be worn for a maximum
of:

a. 7 days
b. 14 days
c. 30 days
d. 45 days - Answer- a. 7 days

The CPC of a rigid lens was ordered 7.84mm and was received measuring 7.94mm.
This lens is _____ than ordered.

a. 0.50D steeper
b. 1.00D flatter
c. 0.50 flatter
d. 1.00D steeper - Answer- c. 0.50 flatter

When comparing high DK silicone acrylate polymers to earlier generation materials of
the same type, the new "improved" silicone acrylates

1 increase oxygen permeability
2 flex less
3 have poorer wetting characteristics
4 scratch less

a. 1 only
b. 1 and 3
c. 2 and 4
d. all are correct - Answer- b. 1 and 3

A normal fitting soft contact lens will have:

a. three point touch (apex and periphery)
b. apical clearance

,c. edge stand-off
d. none of the above - Answer- a. three point touch (apex and periphery)

Therapeutic soft lenses should be fit with minimal movement in which case?

a. Keratitis sicca
b. Trichiasis
c. Recurrent erosion
d. Keratoconus - Answer- c. Recurrent erosion

An aphakic patient with K readings of 40.50 @ 180/41.25 @ 90, large palpebral fissures
and flaccid lower lids is a good candidate for

a. a one cut
b. a myoflange lenticular
c. a hyperflange lenticular
d. a back toric - Answer- b. a myoflange lenticular

When evaluating fluorescein patterns, a special filter must be used with __________.

a. Silicone acrylate
b. Polymethylmethacrylate
c. Fluropolymers
d. Hydroxyethyl methacrylate - Answer- c. Fluropolymers

The keratometer is an instrument used to measure

a. Corneal curvature
b. Lens power
c. Lens diameter
d. Lens thickness - Answer- a. Corneal curvature

A lens fitted for keratoconus should:

a. Flatten the apex
b. Ride high
c. Align the apex
d. Ride low - Answer- c. Align the apex

A soft contact lens which is too loose can show all the following EXCEPT:

a. edge stand-off
b. limbal compression
c. a bubble under the lens edge
d. clear retinoscopy directly after blinking - Answer- b. limbal compression

, Correction of a high riding rigid minus lens is accomplished by using a

a. Flatter lens
b. Larger lens
c. Minus carrier lenticular lens
d. Prism lens - Answer- d. Prism lens


Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is
achieved by the use of the-
a. profile analyzer
b. shadow graph
c. keratometer
d. burton light - Answer- a. profile analyzer

Contact lens power should be specified in-
a. back vertex power
b. sphero-cylinder power
c. power in situ
d. posterier apical radius - Answer- a. back vertex power

The slit-lamp illumination that gives an overall view of the cornea but limits detail is-
a. sclerotic scatter
b. diffuse
c. specular reflection
d. oscilatory - Answer- b. diffuse

When a keratometric miers reflected off a soft contact lens are only clear when the
wearer blinks, the lens fit is too-
a. small
b. large
c. steep
d. flat - Answer- c. steep

Transient keratometric mier distortion is usually due to-
a. pre-ocular tear film abnormalities
b. prolonged rigid lens wear
c. prolonged soft lens wear
d. irregular corneal astigmatism - Answer- a. pre-ocular tear film abnormalities

Epithelial edema which manifests itself clinically as central corneal haze, is verified by
the slit lamp using sclerotic scatter illumination. What specific technique does the
examiner use to see this condition?
a. the naked eye and an angle between the slit lamp beam and the eye of 90˚
b. the blue cobalt filter of the slit lamp and an angle of about 45˚
c. the green filter of the slit lamp with high magnification

Documentinformatie

Geüpload op
19 februari 2026
Aantal pagina's
16
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$14.49

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kan je een ander document kiezen. Je kan het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Scholarsstudyguide
3.8
(169)
Verkocht
846
Volgers
476
Items
16355
Laatst verkocht
2 dagen geleden



Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen