Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 10 pages
Exam (elaborations)

CT - Computed Tomography || 100% Error-free.

Document preview thumbnail
Preview 2 out of 10 pages

CT - Computed Tomography || 100% Error-free.

Content preview

CT - Computed Tomography || 100% Error-free.
Each 1.0% change in contrast between adjacent objects amount to a difference in pixel value of
approximately how many HU? correct answers 10 HU

An IV contrast enhanced specialized CT evaluation of the small bowel after the oral
administration of a low density (0.1%) barium sulfate solution is termed: correct answers CT
Enterography

What is the maximum number of line pairs per centimeter (lp/cm) the smooth algorithm can
demonstrate? correct answers 8.1

A patient is scheduled for an intravenous iodinated contrast-enhanced CT scan of the kidneys.
Prior to injection the involved medical professional personnel should examine recently measured
laboratory values for which of the following?

(1) CBC
(2) Creatinine
(3) PT correct answers Creatinine:

The serum creatinine level is a laboratory value used to measure renal function, and abnormally
elevated values are often signs of renal failure.

Increasing the detector pitch during a spiral CT exam adversely affects the spatial resolution
along which axis? correct answers Z-axis:

Spatial resolution along the Z-axis is decreased as detector pitch is increased.

Which of the following vessels would NOT be used as a site for the injection of iodinated
contrast material?

(1) Cephalic vein
(2) Brachial artery
(3) Antecubital vein
(4) Basilic Vein correct answers (2) Brachial artery:

Intraarterial injections of contrast material are not routinely preformed for CT examinations.

Which of the following laboratory values is used to measure the coagulation ability of a patient
prior to an invasive CT study?

(1) PTT
(2) Hematocrit
(3) PT correct answers 1 & 3:

, Prothrombin Time (PT) & Partial Thromboplastin Time each attempt to detect deficiencies in the
various clotting factors.

The period of peak hepatic parenchymal enhancement following rapid bolus injection of
iodinated contrast is termed the: correct answers Portal venous phase

The primary indication for a non-contrast cardiac MDCT examination is: correct answers
Coronary artery calcium quantification:

Coronary artery calcium (CAC) quantification is for the assessment of atherosclerotic disease.

The excretion half-time of intravenous iodinated contrast media in a patient with normal renal
function is between: correct answers 1 and 2 hours:

Excretion half-time is a value describing the amount of time necessary for 50% of the contrast
media to be filtered by the renal system.

Following a CTA of the chest for pulmonary embolism, an additional acquisition may be
preformed through the lower extremities to evaluate for: correct answers Deep vein thrombosis
(DVT)

DVT, the formation of blood clots in the distal blood vessels, is common in the popliteal and
femoral veins of the lower extremities

Which of the following stages of IV contrast agent administration, provides the best gastric and
intestinal wall enhancement:

(1) Early arterial
(2) Corticomedullary
(3) Portal Venous
(4) Excretory correct answers (3) Portal Venous

Which of the following units is used to quantify effective dose?

(1) Roentgens (R)
(2) Grays (Gy)
(3) Sieverts (Sv)
(4) Curies (Ci) correct answers (3) Sieverts (Sv)

Effective does approximates the relative risk from exposure to ionizing radiation and is based on
the radiosensitivity of a given tissue type.

Evaluation of the venous vascular structures of the brain is known as: correct answers CT
Venography (CTV)

Document information

Uploaded on
February 18, 2026
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.19

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(118)
Sold
796
Followers
438
Items
40095
Last sold
12 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions