ALABAMA ELECTRICAL CONTRACTOR EXAM | COMPLETE EXAM WITH ACTUAL QUESTIONS WITH CORRECT VERIFIED ANSWERS WITH RATIONALES

Rating
-
Sold
-
Pages
65
Grade
A+
Uploaded on
13-02-2026
Written in
2025/2026

ALABAMA ELECTRICAL CONTRACTOR EXAM | COMPLETE EXAM WITH ACTUAL QUESTIONS WITH CORRECT VERIFIED ANSWERS WITH RATIONALES

Institution
ALABAMA ELECTRICAL CONTRACTOR
Course
ALABAMA ELECTRICAL CONTRACTOR

Content preview

ALABAMA ELECTRICAL CONTRACTOR EXAM |
COMPLETE EXAM WITH ACTUAL QUESTIONS WITH
CORRECT VERIFIED ANSWERS WITH RATIONALES


1. According to the NEC, the minimum working space in
front of an electrical panel rated 200A is:
A. 24 inches
B. 30 inches
C. 36 inches
D. 42 inches
Correct Answer: C
Rationale: NEC 110.26(A) requires a minimum of 36 inches
for safe working space in front of equipment ≥600V or rated
>200A.


2. A 3-phase, 480V feeder supplies 50A. What is the
minimum size copper conductor? (Use 75°C rating, THHN)


A. 6 AWG
B. 4 AWG
C. 2 AWG
D. 1 AWG
Correct Answer: B

,Rationale: Using NEC Table 310.16, 75°C copper 4 AWG
handles 85A, exceeding 50A load requirement.


3. A branch circuit supplying a 240V, 3,600W water heater
requires:


A. 15A breaker
B. 20A breaker
C. 25A breaker
D. 30A breaker
Correct Answer: B
Rationale: Current = 3,600 ÷ 240 = 15A. Apply 125% for
continuous load → 15 × 1.25 = 18.75A → next standard
breaker size = 20A.


4. A 120V lighting circuit with 10 fixtures, each 60W,
requires:


A. 5A breaker
B. 10A breaker
C. 15A breaker
D. 20A breaker
Correct Answer: A
Rationale: Total load = 10 × 60W = 600W; Current = 600 ÷
120 = 5A → 5A minimum protection.

,5. Grounding electrode conductor for a 200A service must
be:


A. 6 AWG copper
B. 4 AWG copper
C. 2 AWG copper
D. 1/0 AWG copper
Correct Answer: B
Rationale: NEC Table 250.66 specifies 4 AWG copper for
200A service grounding.


6. Maximum continuous load on a 20A, 120V circuit per NEC
is:


A. 12A
B. 16A
C. 20A
D. 24A
Correct Answer: B
Rationale: Continuous load ≤ 80% of rating → 20 × 0.8 = 16A.


7. Conduit fill for three 3/4-inch THHN conductors in 1-inch
EMT must not exceed:

, A. 20%
B. 40%
C. 53%
D. 60%
Correct Answer: B
Rationale: NEC Chapter 9 Table 1 allows up to 40% fill for 3
conductors in conduit.


8. A 120/240V, single-phase dwelling service for a 4,500
sq.ft house requires a minimum:


A. 100A
B. 150A
C. 200A
D. 250A
Correct Answer: B
Rationale: NEC Article 220 applies load calculations. Typical
modern home ≥150A service.


9. An outdoor service disconnect must be:


A. Rainproof
B. NEMA 1 enclosure

Written for

Institution
ALABAMA ELECTRICAL CONTRACTOR
Course
ALABAMA ELECTRICAL CONTRACTOR

Document information

Uploaded on
February 13, 2026
Number of pages
65
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$21.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
IsaacRobie University of Massachusettss
View profile
Follow You need to be logged in order to follow users or courses
Sold
338
Member since
3 year
Number of followers
156
Documents
4372
Last sold
1 week ago
expert

I am a dedicated and knowledgeable expert specializing in Health Care, Nursing, History, Mathematics, Psychology, and Biology. I provide 100% correct and verified solutions to complex problems in all the named field, with a focus on thorough research and up-to-date information. Please feel free to contact me for any inquiries or assistance.

4.0

77 reviews

5
44
4
10
3
10
2
4
1
9

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions