BACKFLOW TEST QUESTIONS & SOLUTIONS(RATED A+)

Document preview thumbnail
Preview 2 out of 5 pages

If an RPBA contiunually drips or drains under full flow conditions - ANSWER The #2 check valve is fouled When a residential property has a backflow-prevention device/assembly installed on the service line the best means to control thermal expansion is with a - ANSWER Thermal expansion tank According to the Nebraska regulations what is the minimum acceptable air gap for a 2"

Content preview

BACKFLOW TEST QUESTIONS &
SOLUTIONS(RATED A+)
If an RPBA contiunually drips or drains under full flow conditions - ANSWER The #2
check valve is fouled

When a residential property has a backflow-prevention device/assembly installed on the
service line the best means to control thermal expansion is with a - ANSWER Thermal
expansion tank

According to the Nebraska regulations what is the minimum acceptable air gap for a 2"
pipe located 1" from the wall - ANSWER 6"

The RPBA must have a provision to drain away at least _____ times the rated flow of
the assembly - ANSWER 4

When velocity of the water flowing in a service pipe increases, the pressure available at
the consumers tap _________ - ANSWER Decreases

The second check valve of a DCVA has become distorted. What could have caused
this? - ANSWER Water hammer

The RPBA #1 check valve is ___________ - ANSWER A heavier spring than used in
the #2 check valve

The check valve spring of a PVB ________ - ANSWER Closes the check valve

The _____ test cock of an RPBA is located on the inlet side of the assembly - ANSWER
#1

A leaky check valve of a DCVA could be due to _________ - ANSWER The guide
members hanging up

A problem sometimes after repairing a DCVA is _______ - ANSWER A noisy vibration

A differential pressure relief vlave on an RPBA that failed after testing can have two
_________ which must be inspected - ANSWER Diaphragms

When you have re-assembled an RPBA, __________ to detertime if the relief valve has
closed - ANSWER Stick your fingers into the discharge port

The #2 test port of a DCVA is located - ANSWER Between the #1 shutoff valve and the
#1 check valve

, If after repairing a DCVA the device still does not test out "ok" - ANSWER The device
should be disassembled and the check valve seats re-cleaned

The _____ found in the second check valve of an RPBA is different than in the first -
ANSWER Spring

The backflow prevention assembly test report is required to be completed using the
forms (if any) provided by the PWS having jurisidiction because _____ - ANSWER The
grade VI operator is actually a specialized (limited) PWS operator licensed work under
the rules and regulations of a PWS

State drinking water regulations require fire protection sprinkler systems to comply with
______ - ANSWER AWWA Manual M14

What is that Duke, Midwest, Watts and Barton all have in common - ANSWER They all
sell testing equipment for testing RPBAs

When testing a PVB, the test gauge must be - ANSWER At the same height of the
assembly

The air inlet valve of a PVB device - ANSWER Is held open until sufficient pressure is
applied inside the PVB

Which method of protecting against high hazard back siphonage is the best - ANSWER
Air gap

After a backflow prevention assembly has been tested, a copy of the certified results is
provided to the ______ - ANSWER Owner

State regulations place the responsibility on the _______ for records of locations, type
of backflow preventers, and record of repairs of back flow preventers - ANSWER
Consumer

When reassembling components after repairs are made to a backflow prevention device
or assembly - ANSWER An approved nontoxic lubricant may be used

In order to be certain which device/assembly you are about to test, you should -
ANSWER Check and record the make, model, and serial number

A water column 55 1./2" high will create a pressure of _______ psi at the bottom -
ANSWER 2

To smooth a lightyly scratched check valve seat of a PVB, the best choice would be to
use - ANSWER Sand cloth

Document information

Uploaded on
February 12, 2026
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
shantelleG
4.0
(118)
Sold
649
Followers
369
Items
18317
Last sold
21 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions