Relief valve discharges continuously. Problem May be caused by what 5 faults? - ANSWER1. Faulty No. 1 check valve (F1CV) 2. Faulty No. 2 check valve with backpressure (F2CVwB) 3. Faulty relief valve (FRV) 4. Relief valve plugged sensing |ine(s) (RVPSL) 5. Relief Valve leaking diaphragm (RVLD)

Meer zien Lees minder
Instelling
Backflow Prevention Troubleshooting
Vak
Backflow prevention troubleshooting

Voorbeeld van de inhoud

BACKFLOW PREVENTION AND
CROSS CONNECTION CONTROL
CORRECT 100%
Relief valve discharges continuously. Problem May be caused by what 5 faults? -
ANSWER1. Faulty No. 1 check valve (F1CV)
2. Faulty No. 2 check valve with backpressure (F2CVwB)
3. Faulty relief valve (FRV)
4. Relief valve plugged sensing |ine(s) (RVPSL)
5. Relief Valve leaking diaphragm (RVLD)

Relief valve discharges intermittently. Problem May be caused by what 4 faults? -
ANSWER1. Properly working assembly with large pressure fluctuations
2. No.1 check valve reading is close to RV opening point, with small line pressure
fluctuation.
3. Water hammer
4. No. 1 check valve leak with intermittent flow through assembly.

During RP Test 1, Relief Valve discharges after No. 2 shutoff valve is closed. What
does this indicate? - ANSWER1. Normally indicates faulty No. 1 check valve
• Dirty or damaged disc
• Dirty or damaged seat: or,
2. Leak through relief valve diaphragm

During RP Test 1, Relief valve would not open; differential on the field test kit would not
drop. What does this indicate? - ANSWER1. Leaky No. 2 shutoff valve with flow through
the assembly (L2SVwF)

During RP Test 1, Relief valve would not open, differential drops to zero. What does this
indicate? - ANSWER1. Relief valve stuck closed due to corrosion or scale (RVSC).
2. Relief valve sensing line(s) plugged.

During RP Test 1, Relief valve opens too high (with sufficiently high No. 1 check
reading). What does this indicate? - ANSWER1. Faulty relief valve
• Dirty or damaged disc
• Dirty or damaged seat


During PVB Air Inlet Test, Air inlet valve does not open, and reading on field test kit will
not drop. What does this indicate? - ANSWER1. Leaky No. 1 shutoff valve
2. Parallel installation with leaky No. 2 shutoff valve

, During PVB Air Inlet Test, Air inlet valve opens below 1.0 psid, and reading on field test
kit will not drop. What does this indicate? - ANSWER1. Dirty or damaged air inlet valve
disc
2. Scale buildup on seat
3. Damaged spring

During PVB Check Valve Test, Check valve reading below 1.0 psid. What does this
indicate? - ANSWER1. Dirty or damaged check valve disc
2. Dirty or damaged seat
3. Damaged spring

During PVB Check Valve Closing Point Test (Test No. 2), water runs continuously from
test cock No. 2. What does this indicate? - ANSWER1. Leaky No. 1 shutoff valve

During SVB (Either) Test, air inlet valve does not open, as field test kit drops to 0.0 psid.
What does this indicate? - ANSWER1. Air inlet disc stuck to seat
2. Broken or missing air inlet spring
3. Parallel installation with leaky No.2 shutoff valve
4. PVB not SVB

During SVB (Either) Test, Air inlet valve does not open, and reading on field test kit will
not drop. What does this indicate? - ANSWER1. Leaky No. 1 shutoff valve

During SVB (Either) Test, Air inlet opens below 1.0 psid. What does this indicate? -
ANSWER1. Dirty or damaged air inlet disc

During SVB (Check Valve Closing Point) Test 1, Check valve reading below 1.0 psid.
What does this indicate? - ANSWER1. Dirty or damaged check disc
2. Damaged seat
3. Leaking diaphragm/seal

During SVB (Air Inlet Opening Point) Test 2, water runs continuously from vent screw
valve. What does this indicate? - ANSWER1. Leaking No. 1 shutoff valve

What is the purpose and requirement of the RP Test # 1: Relief Valve Opening Point
(USC 10th ed pg 231) - ANSWERPurpose: To test the operation of the differential
pressure relief valve.
Requirement: The differential pressure relief valve must maintain the zone between
the two check valves at least 2 psi less than the supply pressure.

What is the purpose and requirement of the RP Test # 2:Tightness of # 2 Check Valve
(USC 10th ed pg 241) - ANSWERPurpose: To test the # 2 check valve for tightness
against backpressure
Requirement: The # 2 check valve shall be tight against backpressure.

Geschreven voor

Instelling
Backflow prevention troubleshooting
Vak
Backflow prevention troubleshooting

Documentinformatie

Geüpload op
12 februari 2026
Aantal pagina's
5
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

  • backflow prevention
  • backflow
$12.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Thumbnail
Voordeelbundel
BACKFLOW PREVENTION STUDY GUIDE (CHARLESTON WATER SYSTEMS)CORRECT 100% COMPLETE EXAM BUNDLE
-
13 2026
$ 170.37 Meer info

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
shantelleG West Virgina University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
625
Lid sinds
3 jaar
Aantal volgers
369
Documenten
18110
Laatst verkocht
2 weken geleden
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4.0

118 beoordelingen

5
69
4
11
3
24
2
2
1
12

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen