EliteCEU Alarm Level 1 Questions With Complete Solutions
______ do not allow electrons (current) to flow through them.
Correct Answers Insulators
(True or False) Amps can also be called current. Correct
Answers True
(True or False) Electrical tape is used to insulate wires and items
that conduct electricity. Correct Answers True
(True or False) Electricity is a fundamental form of energy
observable in positive and negative forms that occur naturally,
or is produced. it is expressed in terms of movement and
interaction of electrons. Correct Answers True
(True or False) If you are in contact with an energized wire or
any energized electrical component, and with any grounded
object, you will receive a shock. Correct Answers True
(True or False) It's the amps that kill you. Correct Answers True
(True or False) Terminal blocks cannot be cut to size. Correct
Answers False
(True or False) The use of UTP "unshielded twisted pair" uses
category 1 or better cable to transmit video instead of using
coax. Correct Answers False
(True or False) Three phase wiring needs three wires to
complete the circuit, one for each phase. Correct Answers True
,(True or False) You can install a CS-Lens on a CS-Mount
camera with a 5mm spacer ring? Correct Answers False
(True or False) You do not have to strip back the ends of wires
when using some B-connectors. Correct Answers True
(True or False) You will never receive a shock when you are not
in contact with a ground. Correct Answers False
20 decibals are ______ times louder than 1. Correct Answers
100
A ________ circuit has no current flowing through it. Correct
Answers open
A 110 blade is used with what tool? Correct Answers Punch
down tool
A basic system consists of what components? Correct Answers
Optical Device, Transmission means, Power Supply
A bed shaker will: Correct Answers Be limited to one bed at a
time
A closed door between the sounder and mattress can cause a loss
of ___ decibels. Correct Answers 12 to 34
A customer service representative uses ________ daily to arrive
at solutions for customers. Correct Answers problem-solving
A dry contact is a description of a: Correct Answers relay
output
, A given transformer has more turns of wire on the primary side
than the secondary side. This is a ________ transformer. Correct
Answers step down
A PTZ can be controlled by the following means with the
correct hardware in place? Correct Answers Hard Wired
Control, RS485, and Coaxitron
A self contained siren could be directly connected to a: Correct
Answers wet output
A shorted supervised detection circuit will cause the terminal
voltage to go? Correct Answers down
A successful service technician... Correct Answers Always tests
the system before leaving the job
According to NFPA 72, the loudest an audible fire alarm
notification appliance can be is _________ decibels. Correct
Answers 110
According to the FBI Uniform Crime Report, a burglary occurs
every... Correct Answers 14.4 sec
According to the NFPA, the breaker supplying power to an
alarm system shall not be: Correct Answers Greater than 20
amps
ACS are capable of integrating with which of the following
systems? Please select all that apply. Correct Answers Video
Surveillance Systems, Fire/Life-safety, and human resources.
______ do not allow electrons (current) to flow through them.
Correct Answers Insulators
(True or False) Amps can also be called current. Correct
Answers True
(True or False) Electrical tape is used to insulate wires and items
that conduct electricity. Correct Answers True
(True or False) Electricity is a fundamental form of energy
observable in positive and negative forms that occur naturally,
or is produced. it is expressed in terms of movement and
interaction of electrons. Correct Answers True
(True or False) If you are in contact with an energized wire or
any energized electrical component, and with any grounded
object, you will receive a shock. Correct Answers True
(True or False) It's the amps that kill you. Correct Answers True
(True or False) Terminal blocks cannot be cut to size. Correct
Answers False
(True or False) The use of UTP "unshielded twisted pair" uses
category 1 or better cable to transmit video instead of using
coax. Correct Answers False
(True or False) Three phase wiring needs three wires to
complete the circuit, one for each phase. Correct Answers True
,(True or False) You can install a CS-Lens on a CS-Mount
camera with a 5mm spacer ring? Correct Answers False
(True or False) You do not have to strip back the ends of wires
when using some B-connectors. Correct Answers True
(True or False) You will never receive a shock when you are not
in contact with a ground. Correct Answers False
20 decibals are ______ times louder than 1. Correct Answers
100
A ________ circuit has no current flowing through it. Correct
Answers open
A 110 blade is used with what tool? Correct Answers Punch
down tool
A basic system consists of what components? Correct Answers
Optical Device, Transmission means, Power Supply
A bed shaker will: Correct Answers Be limited to one bed at a
time
A closed door between the sounder and mattress can cause a loss
of ___ decibels. Correct Answers 12 to 34
A customer service representative uses ________ daily to arrive
at solutions for customers. Correct Answers problem-solving
A dry contact is a description of a: Correct Answers relay
output
, A given transformer has more turns of wire on the primary side
than the secondary side. This is a ________ transformer. Correct
Answers step down
A PTZ can be controlled by the following means with the
correct hardware in place? Correct Answers Hard Wired
Control, RS485, and Coaxitron
A self contained siren could be directly connected to a: Correct
Answers wet output
A shorted supervised detection circuit will cause the terminal
voltage to go? Correct Answers down
A successful service technician... Correct Answers Always tests
the system before leaving the job
According to NFPA 72, the loudest an audible fire alarm
notification appliance can be is _________ decibels. Correct
Answers 110
According to the FBI Uniform Crime Report, a burglary occurs
every... Correct Answers 14.4 sec
According to the NFPA, the breaker supplying power to an
alarm system shall not be: Correct Answers Greater than 20
amps
ACS are capable of integrating with which of the following
systems? Please select all that apply. Correct Answers Video
Surveillance Systems, Fire/Life-safety, and human resources.