NATE Heat Pump Exam ACTUAL EXAM 2026/2027: 100% Verified Questions & Correct Answers

Document preview thumbnail
Preview 4 out of 44 pages

Ace your NATE (North American Technician Excellence) Heat Pump certification exam with this definitive 2026/2027 guide. It features the actual exam with 100% verified questions and correct answers, covering system components, installation, charging, troubleshooting, electrical diagrams, and EPA regulations. Your key to earning industry-recognized HVAC certification and a top score.

Content preview

NATE Heat Pump Exam ACTUAL
EXAM 2026/2027: 100% Verified
Questions & Correct Answers

Question 1: A technician is troubleshooting a heat pump system in heating mode. The outdoor
ambient temperature is 35°F, and the system is experiencing low suction pressure. The refrigerant
line temperature at the outdoor coil outlet is 28°F. What is the most likely cause?

A. Overcharged system
B. Restricted outdoor coil airflow
C. Failed reversing valve


D. Defective compressor

Correct Answer: B


Rationale: Low suction pressure with a refrigerant line temperature below freezing indicates
insufficient heat transfer at the outdoor coil, typically caused by restricted airflow from dirty coils,
blocked fan, or debris accumulation.




Question 2: During heat pump installation, the technician measures 240V between L1 and L2 at
the outdoor unit contactor, but 0V between L1 and ground. What should be the immediate action?

A. Replace the contactor
B. Check the main electrical panel for a tripped breaker or loose neutral
C. Replace the transformer

,D. Check the thermostat wiring

Correct Answer: B


Rationale: Zero voltage between L1 and ground indicates a missing neutral connection or tripped
breaker, which is a safety hazard that must be addressed before proceeding with system operation.




Question 3: A heat pump system has a measured superheat of 3°F in cooling mode with proper
airflow. The manufacturer specifies 10-12°F superheat. What is the most appropriate adjustment?

A. Add refrigerant
B. Remove refrigerant
C. Replace the expansion valve


D. Increase blower speed

Correct Answer: B


Rationale: Low superheat indicates overcharge condition. Removing refrigerant will increase
superheat to the manufacturer's specified range, ensuring proper system operation and
compressor protection.




Question 4: During defrost cycle initiation, the technician observes that the outdoor fan continues
to run. What component failure would cause this condition?

A. Defrost thermostat
B. Defrost relay contacts welded closed
C. Reversing valve solenoid


D. Outdoor fan motor capacitor

Correct Answer: B

,Rationale: The defrost relay should de-energize the outdoor fan during defrost. Welded contacts
prevent the relay from opening, causing the fan to continue running when it should be off.




Question 5: A heat pump operating in heating mode has a discharge air temperature of 85°F with
70°F return air. The outdoor temperature is 40°F. What does this indicate?

A. Normal operation
B. Supplemental electric heat is energized
C. Reversing valve stuck in cooling position


D. Low refrigerant charge

Correct Answer: B


Rationale: A 15°F temperature rise is excessive for a heat pump alone at 40°F outdoor
temperature, indicating that supplemental electric heat is operating, either due to thermostat
setting or control logic.




Question 6: The technician measures 24VAC at the reversing valve solenoid but the valve does not
shift. What is the most likely cause?

A. Low refrigerant charge
B. Defective reversing valve solenoid coil
C. Failed defrost control board


D. Restricted liquid line drier

Correct Answer: B


Rationale: Proper voltage at the solenoid with no valve movement indicates the solenoid coil is
defective. The coil creates the electromagnetic field needed to shift the valve's internal slide
mechanism.

, Question 7: During heat pump startup in cooling mode, the technician notices the suction pressure
immediately drops to 30 psig and remains there. The outdoor temperature is 85°F. What is the
likely problem?

A. Overcharged system
B. Restricted metering device
C. Oversized system


D. Defective compressor valves

Correct Answer: B


Rationale: An immediate and sustained low suction pressure indicates a restriction in the
refrigerant flow, most commonly at the metering device, preventing proper refrigerant circulation.




Question 8: A homeowner reports insufficient heating. The technician finds the heat pump running
continuously with outdoor coil heavily frosted. The defrost thermostat contacts are closed. What
should be checked first?

A. Reversing valve operation
B. Defrost control board timing and operation
C. Refrigerant charge level


D. Outdoor fan motor amperage

Correct Answer: B


Rationale: Heavy frost accumulation with closed defrost thermostat contacts suggests the defrost
control board is not initiating defrost cycles, indicating a control board malfunction or incorrect
timing settings.

Document information

Uploaded on
January 24, 2026
Number of pages
44
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUDYACEFILES
3.8
(16)
Sold
94
Followers
6
Items
2226
Last sold
16 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions