100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

G35-N G35 - CLASS DF FIRE SUPPRESSION INSTALLATION CONTRACTOR PRACTICE EXAM LATEST QUESTIONS AND CORRECT ANSWERS GRADE A

Rating
-
Sold
-
Pages
34
Grade
A+
Uploaded on
18-01-2026
Written in
2025/2026

G35-N G35 - CLASS DF FIRE SUPPRESSION INSTALLATION CONTRACTOR PRACTICE EXAM LATEST QUESTIONS AND CORRECT ANSWERS GRADE A

Institution
Engineering Technology
Course
Engineering technology











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Engineering technology
Course
Engineering technology

Document information

Uploaded on
January 18, 2026
Number of pages
34
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

G35-N G35 - CLASS DF FIRE SUPPRESSION INSTALLATION CONTRACTOR PRACTICE EXAM
LATEST QUESTIONS AND CORRECT ANSWERS GRADE A



**1. What does "Class DF" refer to in fire suppression systems?**

A) Dry Fire systems

B) Deluge Foam systems

C) Dual-agent Fire suppression

D) Duct and Flammable liquid systems



**Answer: D**

**Explanation:** Class DF systems are designed for protection of ducts and flammable
liquid hazards, combining features of Class D (flammable liquids) and Class F (duct
systems).



**2. According to NFPA 17A, what is the minimum design concentration for wet chemical
systems protecting commercial cooking appliances?**

A) 1.0% wet chemical solution

B) K-25 concentration

C) As tested and listed by UL

D) 6% of protected volume



**Answer: C**

**Explanation:** NFPA 17A requires wet chemical systems to be installed at
concentrations as tested and listed by UL or other recognized testing laboratories for
specific hazards.



**3. What is the maximum travel distance to a fire extinguisher in a commercial kitchen
protected by a Class DF system?**

,A) 30 feet

B) 50 feet

C) 75 feet

D) 100 feet



**Answer: A**

**Explanation:** NFPA 10 requires maximum 30-foot travel distance to Class K
extinguishers in commercial kitchens, even with fixed suppression systems.



**4. Which standard specifically addresses the installation of pre-engineered dry chemical
systems?**

A) NFPA 17

B) NFPA 96

C) NFPA 2001

D) NFPA 13



**Answer: A**

**Explanation:** NFPA 17 covers the installation of dry chemical extinguishing systems,
including pre-engineered systems.



**5. What is the minimum required discharge time for a dry chemical system protecting a
flammable liquid hazard?**

A) 10 seconds

B) 30 seconds

C) 60 seconds

D) Based on hazard analysis

,**Answer: B**

**Explanation:** NFPA 17 typically requires minimum 30-second discharge duration for
flammable liquid hazards, unless specific testing dictates otherwise.



**6. According to NFPA 96, what is the required frequency for inspection of commercial
kitchen fire suppression systems?**

A) Monthly

B) Quarterly

C) Semi-annually

D) Annually



**Answer: C**

**Explanation:** NFPA 96 Section 11.4 requires semi-annual inspection and maintenance
of commercial kitchen fire protection systems by trained personnel.



**7. What type of detection system is typically used in restaurant hood suppression
systems?**

A) Rate-of-rise thermal detectors

B) Fusible links

C) Smoke detectors

D) Flame detectors



**Answer: B**

**Explanation:** Commercial kitchen hood systems typically use fusible links (165°F or
212°F) as the primary detection method due to grease-laden environment.



**8. What is the minimum required flow rate for a water wash system in a commercial
kitchen hood?**

, A) 0.5 gpm per linear foot

B) 0.75 gpm per linear foot

C) 1.0 gpm per linear foot

D) Based on hood listing



**Answer: A**

**Explanation:** NFPA 96 requires minimum 0.5 gpm per linear foot of hood for water wash
systems, with specific patterns and coverage.



**9. Which component must be manually reset after activation of a pre-engineered fire
suppression system?**

A) Detection system

B) Agent cylinder

C) Manual pull station

D) All of the above



**Answer: D**

**Explanation:** After activation, all components including detection, agent cylinders, and
manual actuators must be inspected, reset, or replaced per manufacturer instructions.



**10. What is the maximum allowable spacing between fusible links in a kitchen hood
suppression system?**

A) 6 feet

B) 8 feet

C) 10 feet

D) 12 feet

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
QUANKADA Liberty University
View profile
Follow You need to be logged in order to follow users or courses
Sold
315
Member since
4 year
Number of followers
249
Documents
3878
Last sold
1 week ago
Professionalacademictutor

On this page, you find all documents, package deals, and flashcards offered by seller

3.8

43 reviews

5
25
4
4
3
2
2
6
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions