Chapter 2
What are the 5 major classification buildings are grouped in? - ANSWERType
1: Fire Resistive
Type 2: Non Combustible or protected noncombustible
Type 3: Exterior protected (Masonry) or Ordinary
Type 4: Heavy Timber
Type 5: Wood Frame
Which Building classification does not have a sub-classification? -
ANSWERType 4: heavy timber
NFPA 220 is over what? - ANSWERStandard on types of building construction
In NFPA 220, each classification is designated by a _______________? -
ANSWERThree digit number
,Explain to me what each digit stands for in the NFPA 220 3-digit class -
ANSWER1st digit: Fire resistive rating (in hours) of exterior bearing walls
2nd digit: Fire resistive rating of structural frames or columns and girders that
support loads of more than 1 floor
3rd digit: Fire resistance of floor construction
Example of type 1 three digits
4-4-3. 3-3-2
Steel is what? But not _____________, and must be protected to attain
____________ - ANSWERNon combustible, fire resistant, fire resistance
In a type 1 structure the building is less likely to _______________ on
firefighters? - ANSWERCollapse
Bearing walls, columns, and beams fire resistance in hrs? - ANSWER2-4 hrs
Floor's fire resistance? - ANSWER2-3 hrs
Roof deck and construction supporting roof fire resistance? - ANSWER1-2 hrs
Interior partitions enclosing stairwells and corridors fire resistance? -
ANSWERAs specified by the local code, usually 1-2 hrs
Partitions separating occupancies or tenants' fire resistance? - ANSWERAs
specified by local code
,Concrete is inherently non combustible material with good _____ properties.
- ANSWERThermal insulating
Reinforced concrete can fail under an________ or __________ -
ANSWERExplosion, intense fire of long duration
What kind of wood is usually allowed in a type 1 buildings roof or interior
partitions? - ANSWERFire retardant- treated wood
What kind of plastics can be used in a type 1? - ANSWERLight emitting, foam
plastics subject to restrictions
Type 2
In addition to steel and concrete block, _________ and __________ can be
used with structural load? - ANSWERGlass and Aluminum
Type 2
What omission can cause a type 2 construction building to be classified as
and inspected as a type 1? - ANSWERFire resistive ratings of roof construction
when the roof is more than 20ft above the floor
Type 2
Type 2 (a) protected requires that structured components have ________ fire
resistance? - ANSWER1 hour
Type 2
What is type 2 (b) - ANSWERUnprotected non-combustible
, Type 2
What is the most common characteristic of a unprotected non-combustible
construction? - ANSWERThe use of unprotected steel
Type 2
What factors will tell you the speed at which unprotected members will fail? -
ANSWER-ceiling height of a building
-size of the unprotected members
-intensity and duration of the exposing fire
Type 3 exterior protected/ ordinary
Type 3 construction is frequently constructed with exterior walls of
____________ but from a technical standpoint, any noncombustible material
fire resistance can be used - ANSWERMasonry
Type 3
Interior structural components that are permitted to be partially or wholly
combustible? - ANSWERWalls, columns, beams, floors, and roofs
Type 3
What are two ways a type 3 structure can be protected interior with a rating
of 2-1-1? - ANSWERPlaster in older buildings and gypsum board in newer
Type 3
What nominal size does a type 3 construction commonly use as joist for floor
construction? - ANSWER2"x10"
Review, Exams of Advanced Education
Chapter 2
What are the 5 major classification buildings are grouped in? - ANSWERType
1: Fire Resistive
Type 2: Non Combustible or protected noncombustible
Type 3: Exterior protected (Masonry) or Ordinary
Type 4: Heavy Timber
Type 5: Wood Frame
Which Building classification does not have a sub-classification? -
ANSWERType 4: heavy timber
NFPA 220 is over what? - ANSWERStandard on types of building construction
In NFPA 220, each classification is designated by a _______________? -
ANSWERThree digit number
,Explain to me what each digit stands for in the NFPA 220 3-digit class -
ANSWER1st digit: Fire resistive rating (in hours) of exterior bearing walls
2nd digit: Fire resistive rating of structural frames or columns and girders that
support loads of more than 1 floor
3rd digit: Fire resistance of floor construction
Example of type 1 three digits
4-4-3. 3-3-2
Steel is what? But not _____________, and must be protected to attain
____________ - ANSWERNon combustible, fire resistant, fire resistance
In a type 1 structure the building is less likely to _______________ on
firefighters? - ANSWERCollapse
Bearing walls, columns, and beams fire resistance in hrs? - ANSWER2-4 hrs
Floor's fire resistance? - ANSWER2-3 hrs
Roof deck and construction supporting roof fire resistance? - ANSWER1-2 hrs
Interior partitions enclosing stairwells and corridors fire resistance? -
ANSWERAs specified by the local code, usually 1-2 hrs
Partitions separating occupancies or tenants' fire resistance? - ANSWERAs
specified by local code
,Concrete is inherently non combustible material with good _____ properties.
- ANSWERThermal insulating
Reinforced concrete can fail under an________ or __________ -
ANSWERExplosion, intense fire of long duration
What kind of wood is usually allowed in a type 1 buildings roof or interior
partitions? - ANSWERFire retardant- treated wood
What kind of plastics can be used in a type 1? - ANSWERLight emitting, foam
plastics subject to restrictions
Type 2
In addition to steel and concrete block, _________ and __________ can be
used with structural load? - ANSWERGlass and Aluminum
Type 2
What omission can cause a type 2 construction building to be classified as
and inspected as a type 1? - ANSWERFire resistive ratings of roof construction
when the roof is more than 20ft above the floor
Type 2
Type 2 (a) protected requires that structured components have ________ fire
resistance? - ANSWER1 hour
Type 2
What is type 2 (b) - ANSWERUnprotected non-combustible
, Type 2
What is the most common characteristic of a unprotected non-combustible
construction? - ANSWERThe use of unprotected steel
Type 2
What factors will tell you the speed at which unprotected members will fail? -
ANSWER-ceiling height of a building
-size of the unprotected members
-intensity and duration of the exposing fire
Type 3 exterior protected/ ordinary
Type 3 construction is frequently constructed with exterior walls of
____________ but from a technical standpoint, any noncombustible material
fire resistance can be used - ANSWERMasonry
Type 3
Interior structural components that are permitted to be partially or wholly
combustible? - ANSWERWalls, columns, beams, floors, and roofs
Type 3
What are two ways a type 3 structure can be protected interior with a rating
of 2-1-1? - ANSWERPlaster in older buildings and gypsum board in newer
Type 3
What nominal size does a type 3 construction commonly use as joist for floor
construction? - ANSWER2"x10"