SKILLCAT EPA 608 EXAM QUESTIONS AND ANSWERS VERIFIED 100% CORRECT High pressure or very high pressure appliances except for small appliances and motor vehicle air conditioning. Refrigeration systems containing more than 5 Lbs. of high or very high pressure refrigerants. - ANSWER -What is the definition of a Type II Appliance? Low pressure equipment like low pressure chillers. - ANSWER -What is the definition of a Type III Appliance? 1-399 and 600 and above. - ANSWER -All refrigerants are assumed to be a single chemical if they are numbered what? A mixture of two or more liquids in such a ratio that it's composition cannot be changed by vaporizing it. - ANSWER -What is an Azeotrope? 500 to 599 - ANSWER -Azeotrope's are numbered what? When the refrigerant leaks, it leaks out in different rates due to the different pressures. - ANSWER -What is fractionation? When the temperature of the vaporizing refrigerant changes, even though the pressure remains the same. - ANSWER -What is Temperature Glide? Self-Contained and System-Dependent. - ANSWER -What are the two basic types of recovery devices? 15 Lbs of refrigerant or less - ANSWER -System-Dependent devices may only be used on appliances containing how much refrigerant? A refrigerant label. - ANSWER -What MUST be placed on a refrigerant cylinder being returned for reclaiming. Trapping liquid refrigerant between the service valves. - ANSWER -After completing the transfer of liquid refrigerant between a recovery unit and a refrigeration system, you should guard against what? Charge through a pressure regulator. - ANSWER -When pressurizing a system with nitrogen, you should always? Recover, Recycle, and Reclaim. - ANSWER -What are the three "R's"? To remove refrigerant in any condition from a system and store it in an external approved container. - ANSWER -In relation to the three "R's" what is Recover? To clean refrigerant for reuse by seperating the oil from the refrigerant and removing moisture from the refrigerant by passing it through one or more filter dryers. - ANSWER -In relation to the three "R's" what is Recycle? It cannot be re-sold but it can be re-used. - ANSWER -Can Recycled refrigerant be resold? To process refrigerant to a level equal to new (virgin) product specifications as determined by chemical analysis. - ANSWER -In relation to the three "R's" what is Reclaim? Yes, but must meet the standard set forth in ARI 700 before it can be resold. - ANSWER -Can Reclaimed refrigerant be resold? Chlorine Monoxide (CLO) - ANSWER -What chemical has been found in the stratosphere indicating ozone depletion? 1.Household refrigerators 2.Household freezers 3.Room air conditioners 4.Water Coolers 5.Drinking fountains - ANSWER -What are 5 Type I appliances? 1.Walk-in coolers 2.Walk-in freezers 3.Reach-in refrigerators 4.Reach-in freezers 5.Residential & Commercial comfort cooling systems 6.Ice machines - ANSWER -What are 6 Type II appliances? Low pressure chiller. - ANSWER -What is an example of a Type III appliance? When calculating Superheat. - ANSWER -When is "Dew Point" used? When calculating Sub-cooling. - ANSWER -When is "Bubble Point" used? EPA requires a service aperature (process stub). - ANSWER -What does the EPA require on all Type I equipment that uses Class I or Class II refrigerants. Thermostatic Expansion Valve - ANSWER -TXV 1.Evaporator 2.Condenser 3.Compressor 4.Auxillary Heat Exchanger - ANSWER -The EPA considers a major repair to be the replacement of what 4 items? The charging valve on the evaporator. - ANSWER -When the refrigerant is put back into a Type III chiller, following recovery and system repair, where is it added? Hydrostatic (tube) test - ANSWER -What method is used to find suspected water tube leaks in chillers?

Mostrar más Leer menos
Institución
SKILLCAT EPA 608
Grado
SKILLCAT EPA 608










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
SKILLCAT EPA 608
Grado
SKILLCAT EPA 608

Información del documento

Subido en
7 de enero de 2026
Número de páginas
25
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

SKILLCAT EPA 608 EXAM QUESTIONS
AND ANSWERS VERIFIED 100%
CORRECT
High pressure or very high pressure appliances except for small appliances and
motor vehicle air conditioning. Refrigeration systems containing more than 5 Lbs.
of high or very high pressure refrigerants. - ANSWER -What is the definition of a
Type II Appliance?

Low pressure equipment like low pressure chillers. - ANSWER -What is the
definition of a Type III Appliance?

1-399 and 600 and above. - ANSWER -All refrigerants are assumed to be a single
chemical if they are numbered what?

A mixture of two or more liquids in such a ratio that it's composition cannot be
changed by vaporizing it. - ANSWER -What is an Azeotrope?

500 to 599 - ANSWER -Azeotrope's are numbered what?

When the refrigerant leaks, it leaks out in different rates due to the different
pressures. - ANSWER -What is fractionation?

When the temperature of the vaporizing refrigerant changes, even though the
pressure remains the same. - ANSWER -What is Temperature Glide?

Self-Contained and System-Dependent. - ANSWER -What are the two basic types
of recovery devices?

15 Lbs of refrigerant or less - ANSWER -System-Dependent devices may only be
used on appliances containing how much refrigerant?

,A refrigerant label. - ANSWER -What MUST be placed on a refrigerant cylinder
being returned for reclaiming.

Trapping liquid refrigerant between the service valves. - ANSWER -After
completing the transfer of liquid refrigerant between a recovery unit and a
refrigeration system, you should guard against what?

Charge through a pressure regulator. - ANSWER -When pressurizing a system
with nitrogen, you should always?

Recover, Recycle, and Reclaim. - ANSWER -What are the three "R's"?

To remove refrigerant in any condition from a system and store it in an external
approved container. - ANSWER -In relation to the three "R's" what is Recover?

To clean refrigerant for reuse by seperating the oil from the refrigerant and
removing moisture from the refrigerant by passing it through one or more filter
dryers. - ANSWER -In relation to the three "R's" what is Recycle?

It cannot be re-sold but it can be re-used. - ANSWER -Can Recycled refrigerant
be resold?

To process refrigerant to a level equal to new (virgin) product specifications as
determined by chemical analysis. - ANSWER -In relation to the three "R's" what is
Reclaim?

Yes, but must meet the standard set forth in ARI 700 before it can be resold. -
ANSWER -Can Reclaimed refrigerant be resold?

Chlorine Monoxide (CLO) - ANSWER -What chemical has been found in the
stratosphere indicating ozone depletion?

1.Household refrigerators
2.Household freezers
3.Room air conditioners

, 4.Water Coolers
5.Drinking fountains - ANSWER -What are 5 Type I appliances?

1.Walk-in coolers
2.Walk-in freezers
3.Reach-in refrigerators
4.Reach-in freezers
5.Residential & Commercial comfort cooling systems
6.Ice machines - ANSWER -What are 6 Type II appliances?

Low pressure chiller. - ANSWER -What is an example of a Type III appliance?

When calculating Superheat. - ANSWER -When is "Dew Point" used?

When calculating Sub-cooling. - ANSWER -When is "Bubble Point" used?

EPA requires a service aperature (process stub). - ANSWER -What does the EPA
require on all Type I equipment that uses Class I or Class II refrigerants.

Thermostatic Expansion Valve - ANSWER -TXV

1.Evaporator
2.Condenser
3.Compressor
4.Auxillary Heat Exchanger - ANSWER -The EPA considers a major repair to be
the replacement of what 4 items?

The charging valve on the evaporator. - ANSWER -When the refrigerant is put
back into a Type III chiller, following recovery and system repair, where is it
added?

Hydrostatic (tube) test - ANSWER -What method is used to find suspected water
tube leaks in chillers?
$14.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TheExamMaestro Teachme2-tutor
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
121
Miembro desde
1 año
Número de seguidores
5
Documentos
3167
Última venta
5 días hace
Exam Vault

Exam Vault is your trusted destination for high-quality exam materials and study resources. We provide a wide rage of tests and prep guides to help you succeed, whether you're preparing for academic exams, certifications, or professional assessments

3.8

13 reseñas

5
7
4
2
3
1
2
0
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes