Oil burner License Study Guide ( Massachusetts ) Exam With Complete Solutions
What size is the oil line for a residential burner? - ANSWER-3/8 
 
Largest oil capacity for residential without a license? - ANSWER-10,000 Gallons 
 
At what height ceiling would a second thermal switch be required? - ANSWER-12' 
 
A typical residential oil burner is also s/u to run Kerosene True? Or False? - ANSWER-False 
 
Permit to install an oil burner is issued by the? - ANSWER-State Fire Marshall 
 
Draft measurements are taken in what? - ANSWER-Inches of water column 
 
Pressure Relief ...
- Package deal
- Examen
- • 9 páginas •
What size is the oil line for a residential burner? - ANSWER-3/8 
 
Largest oil capacity for residential without a license? - ANSWER-10,000 Gallons 
 
At what height ceiling would a second thermal switch be required? - ANSWER-12' 
 
A typical residential oil burner is also s/u to run Kerosene True? Or False? - ANSWER-False 
 
Permit to install an oil burner is issued by the? - ANSWER-State Fire Marshall 
 
Draft measurements are taken in what? - ANSWER-Inches of water column 
 
Pressure Relief ...
Oil burner test Exam Questions & Answers 100% Correct
vent pipes must be atleast ______ feet above or _______ feet below any window or door. they must also be _____ get away from property line to prevent sewer gas from drifting to neighbors house - ANSWER-3 feet above or 5 feet below door or window. 
3 feet from property line 
 
To make combustion efficiency test, a whole must be made - ANSWER-In the flue pipe before the draft control 
 
What three colors does the NEC allowed to be used for ground wire? - ANSWER-Green, bare of green with yellow str...
- Package deal
- Examen
- • 4 páginas •
vent pipes must be atleast ______ feet above or _______ feet below any window or door. they must also be _____ get away from property line to prevent sewer gas from drifting to neighbors house - ANSWER-3 feet above or 5 feet below door or window. 
3 feet from property line 
 
To make combustion efficiency test, a whole must be made - ANSWER-In the flue pipe before the draft control 
 
What three colors does the NEC allowed to be used for ground wire? - ANSWER-Green, bare of green with yellow str...
Oil Furnace Heating Practice Tests Exam Questions and Answers 100% Solved
A ______ carbon dioxide content is usually caused by insufficient draft or an overfired burner 
 
 low 
 high - ANSWER-high 
 
A _______ stack thermometer is generally used to measure the flue gas temperature in oil heating system: 
 
 200/2000°F 
 100/1000°F 
 200/1000°F 
 100/2000°F - ANSWER-200/1000°F 
 
Delayed ignition is mainly traced to a problem with which of the following: 
 
 Stoker 
 Electrodes 
 Burner Nozzle 
 Oil pump - ANSWER-Electrodes 
 
The advantage of the _______ of oil ...
- Package deal
- Examen
- • 4 páginas •
A ______ carbon dioxide content is usually caused by insufficient draft or an overfired burner 
 
 low 
 high - ANSWER-high 
 
A _______ stack thermometer is generally used to measure the flue gas temperature in oil heating system: 
 
 200/2000°F 
 100/1000°F 
 200/1000°F 
 100/2000°F - ANSWER-200/1000°F 
 
Delayed ignition is mainly traced to a problem with which of the following: 
 
 Stoker 
 Electrodes 
 Burner Nozzle 
 Oil pump - ANSWER-Electrodes 
 
The advantage of the _______ of oil ...
120, Ch3, Oil Burners Summary Exam Questions & Answers 100% Accurate1
3 systems of an oil burner - ANSWER-Every oil burner must have 
an air delivery system, 
a fuel delivery system, and 
an ignition system. 
 
How are oil burners classified? - ANSWER-Classified by the method used to prepare the fuel for combustion. 
 
Which type of oil burner dominates the residential market? - ANSWER-high-pressure gun-type oil burners. 
 
Advances in recent years have centered around what type of oil burner? - ANSWER-Flame retention head oil burners. 
 
How does an oil burner ...
- Package deal
- Examen
- • 2 páginas •
3 systems of an oil burner - ANSWER-Every oil burner must have 
an air delivery system, 
a fuel delivery system, and 
an ignition system. 
 
How are oil burners classified? - ANSWER-Classified by the method used to prepare the fuel for combustion. 
 
Which type of oil burner dominates the residential market? - ANSWER-high-pressure gun-type oil burners. 
 
Advances in recent years have centered around what type of oil burner? - ANSWER-Flame retention head oil burners. 
 
How does an oil burner ...
MA oil burners test Exam Questions & Answers Scored A
Boiler, High Pressure). - ANSWER-. A boiler for generating steam at pressures in excess of 15 psi (103 kPa), or for heating water to a temperature in excess of 250°F (121°C) or at a pressure in excess of 160 psi (1103 kPa). 
 
Boiler, Hot Water Supply. - ANSWER-A low-pressure hot water boiler having a volume exceeding 120 gallons (454 L), or a heat input exceeding 200,000 Btu per hour (58.6 kw) or an operating temperature exceeding 200°F (93°C) that provides hot water to be used externally t...
- Package deal
- Examen
- • 12 páginas •
Boiler, High Pressure). - ANSWER-. A boiler for generating steam at pressures in excess of 15 psi (103 kPa), or for heating water to a temperature in excess of 250°F (121°C) or at a pressure in excess of 160 psi (1103 kPa). 
 
Boiler, Hot Water Supply. - ANSWER-A low-pressure hot water boiler having a volume exceeding 120 gallons (454 L), or a heat input exceeding 200,000 Btu per hour (58.6 kw) or an operating temperature exceeding 200°F (93°C) that provides hot water to be used externally t...
Massachusetts oil burner study guide Exam With Complete Solutions!!
What does InStep mean - ANSWER-The stack relay is operating properly 
 
How is combustion achieved - ANSWER-Atomization ,air ,ignition. 
 
What is the minimum size oil line for residential burners - ANSWER-3/8 inch 
 
How is safety timing checked on a stack relay switch - ANSWER-Remove the stack relay from the duck and let it run .it should shut off in 45 seconds. 
 
What is the safety lockout time on Burner firing under 3 gallons per hour - ANSWER-45 seconds 
 
What control devices are found on...
- Package deal
- Examen
- • 18 páginas •
What does InStep mean - ANSWER-The stack relay is operating properly 
 
How is combustion achieved - ANSWER-Atomization ,air ,ignition. 
 
What is the minimum size oil line for residential burners - ANSWER-3/8 inch 
 
How is safety timing checked on a stack relay switch - ANSWER-Remove the stack relay from the duck and let it run .it should shut off in 45 seconds. 
 
What is the safety lockout time on Burner firing under 3 gallons per hour - ANSWER-45 seconds 
 
What control devices are found on...
Chapters 1&2 - Oil and Oil Burners Exam Questions and Answers Rated A
Which of the three elements needed for combustion is the key element and final adjustment of an oil burner - ANSWER-Air 
 
What does the tertiary air that exists around the outside of the flame retention ring or thru the tertiary slots do - ANSWER-Ensures that and escaping oil spray will be burned 
 
What are all the popular new burners designed to deliver high static pressure - ANSWER-Forces products of combustion thru the heat exchanger without the use of a chimney or power venter 
 
What is t...
- Package deal
- Examen
- • 3 páginas •
Which of the three elements needed for combustion is the key element and final adjustment of an oil burner - ANSWER-Air 
 
What does the tertiary air that exists around the outside of the flame retention ring or thru the tertiary slots do - ANSWER-Ensures that and escaping oil spray will be burned 
 
What are all the popular new burners designed to deliver high static pressure - ANSWER-Forces products of combustion thru the heat exchanger without the use of a chimney or power venter 
 
What is t...
Residential Oil Burners Chapter 1 Exam Questions and Answers Rated A+
The purpose of the gauge glass on steam boiler is what? - ANSWER-tells how much water is in boiler 
 
What is also on a steam heating system that tells how much water is in it? - ANSWER-pressure gauge that reads from 0 to 15 psi steam safety valve 
 
When there is a call for heat what happens to a steam heating system? - ANSWER-burner heats water generates steam 
 
where does the steam go? - ANSWER-enters radiators in building heats house 
 
After temp has been reached what happens to the steam?...
- Package deal
- Examen
- • 2 páginas •
The purpose of the gauge glass on steam boiler is what? - ANSWER-tells how much water is in boiler 
 
What is also on a steam heating system that tells how much water is in it? - ANSWER-pressure gauge that reads from 0 to 15 psi steam safety valve 
 
When there is a call for heat what happens to a steam heating system? - ANSWER-burner heats water generates steam 
 
where does the steam go? - ANSWER-enters radiators in building heats house 
 
After temp has been reached what happens to the steam?...
Oil Furnace Troubleshooting Exam Questions and Answer 100% Pass
What is the size of an air vent on an oil storage tank? - ANSWER-1 1/4" 
 
What safety feature is used on an inside oil storage tank that will protect against a house fire? - ANSWER-a fuse-type globe valve 
 
What effect, if any, would a decrease of primary air have on combustion? - ANSWER-It would increase CO2 percentage 
 
What effect if any would an increase in primary air have on combustion? - ANSWER-It would decrease CO2 percentage 
 
If an oil has a high viscosity - ANSWER-It is a thicker...
- Package deal
- Examen
- • 9 páginas •
What is the size of an air vent on an oil storage tank? - ANSWER-1 1/4" 
 
What safety feature is used on an inside oil storage tank that will protect against a house fire? - ANSWER-a fuse-type globe valve 
 
What effect, if any, would a decrease of primary air have on combustion? - ANSWER-It would increase CO2 percentage 
 
What effect if any would an increase in primary air have on combustion? - ANSWER-It would decrease CO2 percentage 
 
If an oil has a high viscosity - ANSWER-It is a thicker...
NATE ICE Residential Oil Heat Exam Questions With Answers Verified By Experts!!
On a "no heat" service call for an oil-fired furnace, what is the main safety precaution that the technician must take before attempting to fire the oil furnace? - ANSWER-check the combustion chamber for liquid oil 
 
On start-up of an oil unit, the technician's smoke test shows the unit to have a #8 smoke. Which of the following is the correct action that should be taken? - ANSWER-increase primary air 
 
The primary reason for using a barometric draft control on an oil furnace is to maintain...
- Package deal
- Examen
- • 3 páginas •
On a "no heat" service call for an oil-fired furnace, what is the main safety precaution that the technician must take before attempting to fire the oil furnace? - ANSWER-check the combustion chamber for liquid oil 
 
On start-up of an oil unit, the technician's smoke test shows the unit to have a #8 smoke. Which of the following is the correct action that should be taken? - ANSWER-increase primary air 
 
The primary reason for using a barometric draft control on an oil furnace is to maintain...
PALS Exam 2023-2024 Questions & Answers ( Correct 100%)