1. In a dry type (direct expansion) evaporator, liquid refrigerant must boil away as close to the end of the coil as possible in order to: 
A. Operate at high-efficiency 
B. Ensure that Frost is not accumulate 
C. Subcool the compressor 
D. Ensure proper oil return - Answer- A. Operate at high-efficiency 
 
2. The difference between the temperature of the refrigerant boiling in the evaporator and the temperature at the evaporator ...
Examen
REFRIGERATION EXCELLENCE EXAM 2025/2026 QUESTIONS AND ANSWERS 100% PASS
REFRIGERATION EXCELLENCE EXAM 
2025/2026 QUESTIONS AND ANSWERS 
100% PASS
Examen
Refrigeration Excellence Questions and Correct Answers/ Latest Update / Already Graded
Refrigeration Excellence Questions and 
Correct Answers/ Latest Update / Already 
Graded
Examen
REFRIGERATION EXCELLENCE 100 QUESTIONS WITH PASSED GRADES!!
REFRIGERATION EXCELLENCE 100 QUESTIONS WITH PASSED GRADES!!
Examen
REFRIGERATION EXCELLENCE LATEST EXAM 2025 WITH MULTIPLE CHOICE OF QUESTIONS AND DETAILED CORRECT ANSWERS ALREADY GRADED A+ AND 100% GUARANTEE PASS (BRAND NEW!!!!!)
6. A technician is checking the superheat on a multi circuit evaporator and finds one of the circuits has a superheat that is higher than the others. This could be caused by 
A. A dirty coil 
B. A refrigerant overcharge 
C. Uneven air distribution 
D. A blocked distributor - CORRECT ANSWER-D. A blocked distributor 
 
7. A TXV with an external equalizer is used on 
A. Evaporators with a high pressure drop 
B. Evaporators with a low pressure drop 
C. High temperature application is only 
D. All ev...
Examen
Refrigeration Excellence Questions and Answers Already Passed
Refrigeration Excellence Questions and 
 
Answers Already Passed 
 
8. Dry type evaporators operate most efficiently with the superheat setting of approximately 
A. 8°F to 12°F 
B. 13°F to 19°F 
 
C. 20°F to 30°F 
 
D. 31°F to 40°F A. 8°F to 12°F 
 
9. An evaporator used to chill liquids is operating within normal superheat setting. But the 
system is not cooling the product properly. Which of the following is most likely the cause? 
A. Overcharge of refrigerant 
B. Undercharge of refr...