A Hydrotest is conducted on an underground line as a substitute for the external inspection. The 
test pressure is 200 Psig. At the end of the test, the pressure must be at least - API 570 9.8.6 
190 Psig. 
Determine the maximum allowed pressure for a Class 300 flange that has a design temperature 
of 950 °F. The flange material is ASTM A217 Gr. C12 - B16.5 Table 1.1-1 
375 Psig. 
An 8 NPS pipe is being replaced with A106 gr. B mater...
Exam (elaborations)
API 570 - Open Book - Practice Exam 2024 Already Passed
PopularA Hydrotest is conducted on an underground line as a substitute for the external inspection. The 
test pressure is 200 Psig. At the end of the test, the pressure must be at least - API 570 9.8.6 
190 Psig. 
Determine the maximum allowed pressure for a Class 300 flange that has a design temperature 
of 950 °F. The flange material is ASTM A217 Gr. C12 - B16.5 Table 1.1-1 
375 Psig. 
An 8 NPS pipe is being replaced with A106 gr. B material. The pipe retirement thickness (Tmin) 
is 0.218" and the ...