EPA 608 Core Universal ACTUAL 
QUESTIONS AND CORRECT ANSWERS 
Refrigeration technicians who violate the Clean Air Act can: - CORRECT 
ANSWERSD) all of the above. 
After 1995, any supplies of CFC refrigerant to service existing units in the USA can only 
come from: - CORRECT ANSWERSA) recovery and recycling. 
Refrigerant that is recovered can be returned to: - CORRECT ANSWERSA) the same 
system or other systems owned by the same person without restriction. 
Refrigerant can not be called ...
- Exam (elaborations)
- • 15 pages's •
-
EPA•EPA
Preview 2 out of 15 pages
Getting your document ready...
EPA 608 Core Universal ACTUAL 
QUESTIONS AND CORRECT ANSWERS 
Refrigeration technicians who violate the Clean Air Act can: - CORRECT 
ANSWERSD) all of the above. 
After 1995, any supplies of CFC refrigerant to service existing units in the USA can only 
come from: - CORRECT ANSWERSA) recovery and recycling. 
Refrigerant that is recovered can be returned to: - CORRECT ANSWERSA) the same 
system or other systems owned by the same person without restriction. 
Refrigerant can not be called ...
EPA 608 (TYPE II) Exam ACTUAL 
QUESTIONS AND CORRECT ANSWERS 
When a new system has been assembled, the first thing to do is? - CORRECT 
ANSWERSPressurize the system with an inert gas & leak check. 
After installation of a field-piped R-410A split heat pulp, the unit should first be? - 
CORRECT ANSWERSPressurized with nitrogen then leak checked. 
The EPA regulations require that any appliances containing more than 50 pounds of 
refrigerant (except for commercial & industrial process refri...
- Exam (elaborations)
- • 8 pages's •
-
EPA•EPA
Preview 2 out of 8 pages
Getting your document ready...
EPA 608 (TYPE II) Exam ACTUAL 
QUESTIONS AND CORRECT ANSWERS 
When a new system has been assembled, the first thing to do is? - CORRECT 
ANSWERSPressurize the system with an inert gas & leak check. 
After installation of a field-piped R-410A split heat pulp, the unit should first be? - 
CORRECT ANSWERSPressurized with nitrogen then leak checked. 
The EPA regulations require that any appliances containing more than 50 pounds of 
refrigerant (except for commercial & industrial process refri...
EPA Section 608-Module 0119 Technician 
Certification ACTUAL QUESTIONS AND 
CORRECT ANSWERS 
The over-evacuation of a system: - CORRECT ANSWERSdoes not occur 
According to the ASHARE refrigerant safety classification standard, which of the following 
designations would be the safest? - CORRECT ANSWERSA1 
What does ozone in the stratosphere above the earth consists of? - CORRECT 
ANSWERSmolecules containing 3 oxygen atoms 
How many ozone molecules can each chlorine atom in the stratospher...
- Exam (elaborations)
- • 11 pages's •
-
EPA•EPA
Preview 2 out of 11 pages
Getting your document ready...
EPA Section 608-Module 0119 Technician 
Certification ACTUAL QUESTIONS AND 
CORRECT ANSWERS 
The over-evacuation of a system: - CORRECT ANSWERSdoes not occur 
According to the ASHARE refrigerant safety classification standard, which of the following 
designations would be the safest? - CORRECT ANSWERSA1 
What does ozone in the stratosphere above the earth consists of? - CORRECT 
ANSWERSmolecules containing 3 oxygen atoms 
How many ozone molecules can each chlorine atom in the stratospher...
EPA Section 608 Refrigerant Management 
Guidelines ACTUAL QUESTIONS AND 
CORRECT ANSWERS 
Yellow Top - CORRECT ANSWERSColor indicating approved refrigerant recovery 
cylinder. 
Grey Body - CORRECT ANSWERSStandard color for refrigerant recovery cylinders. 
Refrigerant Recovery Cylinder - CORRECT ANSWERSContainer for storing recovered 
refrigerants. 
80% Capacity Rule - CORRECT ANSWERSCylinders should be filled to 80% by 
weight. 
Hydrostatic Testing - CORRECT ANSWERSTesting required eve...
- Exam (elaborations)
- • 9 pages's •
-
EPA•EPA
Preview 2 out of 9 pages
Getting your document ready...
EPA Section 608 Refrigerant Management 
Guidelines ACTUAL QUESTIONS AND 
CORRECT ANSWERS 
Yellow Top - CORRECT ANSWERSColor indicating approved refrigerant recovery 
cylinder. 
Grey Body - CORRECT ANSWERSStandard color for refrigerant recovery cylinders. 
Refrigerant Recovery Cylinder - CORRECT ANSWERSContainer for storing recovered 
refrigerants. 
80% Capacity Rule - CORRECT ANSWERSCylinders should be filled to 80% by 
weight. 
Hydrostatic Testing - CORRECT ANSWERSTesting required eve...
Type III Refrigeration: Low-Pressure 
Chillers, Leak Regulations, and EPA 
Compliance ACTUAL QUESTIONS AND 
CORRECT ANSWERS 
What is Type III certification for? - CORRECT ANSWERSIt is for technicians working 
with low-pressure appliances. 
What defines a low-pressure appliance? - CORRECT ANSWERSAn appliance that uses 
a refrigerant with a liquid-phase saturation pressure below 30.3 psig at 104°F. 
Which refrigerants are considered low-pressure? - CORRECT ANSWERSR-11, R-123, 
R-113, R-2...
- Exam (elaborations)
- • 7 pages's •
-
EPA•EPA
Preview 2 out of 7 pages
Getting your document ready...
Type III Refrigeration: Low-Pressure 
Chillers, Leak Regulations, and EPA 
Compliance ACTUAL QUESTIONS AND 
CORRECT ANSWERS 
What is Type III certification for? - CORRECT ANSWERSIt is for technicians working 
with low-pressure appliances. 
What defines a low-pressure appliance? - CORRECT ANSWERSAn appliance that uses 
a refrigerant with a liquid-phase saturation pressure below 30.3 psig at 104°F. 
Which refrigerants are considered low-pressure? - CORRECT ANSWERSR-11, R-123, 
R-113, R-2...
EPA 608 CERTIFICATION EXAM LATEST ACTUAL EXAM ALL 300 REAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) ALREADY GRADED A+.pdf
- Book & Paket-Deal
- Exam (elaborations)
- • 56 pages's •
-
EPA•EPA
-
Phlebotomy Exam Review • Ruth McCall• ISBN 9781451194548
-
test bank iecvabmxhsir• By PROFfESORMcCullough
Preview 4 out of 56 pages
Getting your document ready...
EPA 608 CERTIFICATION EXAM LATEST ACTUAL EXAM ALL 300 REAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) ALREADY GRADED A+.pdf
_______ is the process of removing refrigerant in any condition from a system and storing it in an external container without necessarily testing or processing it in any way. - Recovering - ans^ 
 
______________refers to the process of cleaning refrigerant by oil separation and single or multiple passes through filter-driers, which reduce moisture and acidity? - Recycling - ans^ 
 
_________is the process that returns refrigerant to new-product specifications and that requires chemical analysis...
- Exam (elaborations)
- • 15 pages's •
-
Epa•Epa
Preview 2 out of 15 pages
Getting your document ready...
_______ is the process of removing refrigerant in any condition from a system and storing it in an external container without necessarily testing or processing it in any way. - Recovering - ans^ 
 
______________refers to the process of cleaning refrigerant by oil separation and single or multiple passes through filter-driers, which reduce moisture and acidity? - Recycling - ans^ 
 
_________is the process that returns refrigerant to new-product specifications and that requires chemical analysis...
When a new system has been assembled, the first thing to do is? 
Pressurize the system with an inert gas & leak check. 
After installation of a field-piped R-410A split heat pulp, the unit should first be? 
Pressurized with nitrogen then leak checked. 
The EPA regulations require that any appliances containing more than 50 pounds of 
refrigerant (except for commercial & industrial process refrigeration) must be repaired 
when the leak rate exceeds _________ of the charge per year? 
15% 
R-410A...
- Exam (elaborations)
- • 5 pages's •
-
EPA•EPA
Preview 2 out of 5 pages
Getting your document ready...
When a new system has been assembled, the first thing to do is? 
Pressurize the system with an inert gas & leak check. 
After installation of a field-piped R-410A split heat pulp, the unit should first be? 
Pressurized with nitrogen then leak checked. 
The EPA regulations require that any appliances containing more than 50 pounds of 
refrigerant (except for commercial & industrial process refrigeration) must be repaired 
when the leak rate exceeds _________ of the charge per year? 
15% 
R-410A...