Exam (elaborations)
NATE Air Conditioning and Heat Pump Questions with Correct Answers
NATE Air Conditioning and Heat Pump 
Questions with Correct Answers 
What is the indoor air flow for an electric furnace when the supply air temperature is 98 degrees 
F, the return air temperature is 70 degrees F, the voltage being supplied to the furnace is 220 V, 
and the current draw of the furnace is 47 A? 1,170 cfm 
Which of the following statements about understanding wiring diagrams is Not true? 
 Schematics are always shown with the circuits energized
Exam (elaborations)
NATE AIR CONDITIONING AND HEAT PUMPS Questions With Complete Solutions
PopularNATE AIR CONDITIONING AND HEAT 
PUMPS Questions With Complete Solutions 
The auxiliary drain line from an overflow pan must _____________. 
A. Be connected to the primary condensate drain line using an approved P-trap 
B. Be terminated at some conspicuous location so that an overflow is readily noticed 
C. Have a diameter of at least 1 inch 
D. Never be insulated B. Be terminated at some suspicious location so that An overflow is 
readily noticed
Exam (elaborations)
NATE Heat Pump Questions with Verified Answers
NATE Heat Pump Questions with Verified 
Answers 
Electronic air cleaners can operate with internal voltages as high as... 5000V 
A "cross-break" made on all flat sides of any rectangular section of metal duct will... Increase 
rigidity and reduce vibration 
The terms grille and register are often used interchangeably. There is a difference between these 
components. The primary difference between a grille and a register is... A register is equipped 
with an air volume control device, w...
Exam (elaborations)
NATE Heat Pump Questions with Complete Solutions
NATE Heat Pump Questions with Complete 
Solutions 
The terms grille and register are often used interchangeably. There is a difference between these 
two components. The primary difference between a grille and a register is... a register is 
equipped with an air volume control device and a grille is not 
Thermostatic expansion valves (TXV) meter refrigerant flow to a coil to... maintain 
superheated refrigerant leaving the coil
Exam (elaborations)
NATE Exam: Air Conditioning and Heat Pumps Questions and Answers Graded A+
NATE Exam: Air Conditioning and Heat 
Pumps Questions and Answers Graded A+ 
Which component pumps refrigerant through the system and raises the vapor temperature? 
a. Accumulator 
b. Compressor 
c. Condenser 
d. Evaporator b (Compressor)
Exam (elaborations)
NATE heat pump Questions with Complete Solutions
NATE heat pump Questions with Complete 
Solutions 
When changing out an evaporator coil the installer must be certain to plumb the cabinet so its 
sides are vertical 
The recommended maximum external static pressure used for heating and cooling equipment 
with blowers for 5 ton of cooling or less is 0.1 in W.C 
When a balancing check of a newly installed duct system the dampers should be open 
completely in all rooms