IYRS Electrical ABYC Exam Questions and Verified Answers 100%
-
---8August 20252025/2026A+
- IYRS Electrical ABYC Exam Questions and Verified Answers 100% 
15 - correct answer The minimum amp circuit breaker that should be used to protect a 120V water heater circuit with a 1600-watt element would be rated at ________ amps 
 
Gauss Meter - correct answer When testing for excessive EMF emission near a conductor or appliance, the tool of choice is a 
 
voltage drop across each load will be excessive - correct answer The primary problem with using a series circuit to supply multiple loads i...
-
$14.49 More Info
Stuvia71
-
Exam (elaborations)
IYRS Electrical ABYC Exam Questions and Verified Answers
-
--8August 20252025/2026AAvailable in bundle
- IYRS Electrical ABYC Exam Questions and Verified Answers 
0 amps - correct answer How much current should flow through the 
DC grounding conductor in a 25-amp DC motor circuit 
 
0 AWG - correct answer A technician is installing the cable run from the batteries to the main DC panelboard on a boat aspart of a refit. The boat has a 12-volt system, and the distance from the panel to the batteries is 15 ft (approximately 3 m).The maximum current draw from the panel is calculated at 90 amps.What gau...
-
$12.49 More Info
Stuvia71
-
Exam (elaborations)
IYRS Electrical ABYC Exam | Questions with Correct Answers | Latest Update (2025/2026)
-
--8July 20252024/2025A+Available in bundle
- IYRS Electrical ABYC Exam | Questions with Correct Answers | Latest Update 
(2025/2026)
-
$13.49 More Info
Darkberry
-
Exam (elaborations)
IYRS Electrical ABYC Exam Questions With Correct Verified Complete Solutions
-
---8March 20252024/2025A+
- AC receptacles may be used for DC service based on ABYC standards as 
long as they are - Never used for DC service 
Motor circuits that do not provide their own integrated thermal cutout 
must be fused based on - Motor vendor recommendations 
When testing for a non-functional tachometer on a Diesel engine with a 
signal generator as the rpm signal source, the technician should use - 
 a DVOM set to the AC volts scale 
When testing a temperature gauge, the technician removes the wire 
from t...
-
$8.99 More Info
jackline98
-
Exam (elaborations)
IYRS Electrical ABYC Exam Questions & Verified Answers 2024-2025 | 100% Pass Rate | | 100% Success Guarantee | Easy-to-Download
-
---12November 20242024/2025A+
- IYRS Electrical ABYC Exam Questions & 
Verified Answers | 100% 
Pass Rate | | 100% Success Guarantee | 
Easy-to-Download
-
$11.99 More Info
JordanBrook