- Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about ? On this page you'll find 15 study documents about .
All 15 results
Sort by:
-
Exam (elaborations)
BREAST ARDMS EXAM QUESTIONS AND ANSWERS 2025
-
--114October 20252025/2026A+Available in bundle
- BREAST ARDMS EXAM QUESTIONS AND ANSWERS 2025
-
$18.49 More Info
Teacher101
-
Exam (elaborations)
DAVIES BREAST ARDMS EXAM 2025 QUESTIONS AND ANSWERS
-
---69July 20252024/2025A+
- Which artifact may cause structures to look deeper than they actually are? 
A. Side lobe 
B. Shadowing 
C. Refraction 
D. Propagation speed error 
E. Slice thickness - ANS D. propagation speed error 
The optimum operating frequency for a broad-bandwidth transducer would 
be: 
A. 6 MHz 
B. 7 MHz 
C. 8 MHz 
D. 9 MHz 
E. 10 MHz - ANS C. 8 
In breast sonography, which of the following is NOT significantly affected by the limited field of 
view when imaging superficial structures? 
A. Contrast resolu...
-
$14.99 More Info
Thebright
-
Exam (elaborations)
BREAST ARDMS Comprehensive Exam Review Guide, Over 500 Test Questions & Answers
-
--42June 20252024/2025A+Available in bundle
- BREAST ARDMS Comprehensive Exam Review Guide, Over 500 Test Questions & Answers-which artifact may cause structures to look deeper than they actually are? 
A. side lobe 
B. shadowing 
C. refraction 
D. propagation speed error 
E. slice thickness - D. propagation speed error 
 
the optimum operating frequency for a broad-bandwidth transducer would be: 
A. 6 MHz 
B. 7 MHz 
C. 8 MHz 
D. 9 MHz 
E. 10 MHz - C. 8 MHz 
 
in breast sonography, which of the following is NOT significantly affected by the ...
-
$14.14 More Info
ProfMiaKennedy
-
Exam (elaborations)
BREAST ARDMS Comprehensive Test Questions With Verified Answers Graded A+
-
---110November 20242024/2025A+
- BREAST ARDMS Comprehensive Test Questions With 
Verified Answers Graded A+ 
A standoff pad thicker than 1 cm is not recommended because it will :☑️Correct Ans-Affect the 
optimal placement of the fixed elevation plane focus 
Which type of transducer does NOT allow the sonographer to vary the focusing 
capabilities?☑️Correct Ans-Mechanical sector
-
$15.49 More Info
TutorNest
-
Exam (elaborations)
BREAST ARDMS EXAM REVIEW WITH COMPLETE SOLUTIONS
-
--18April 20242023/2024A+Available in bundle
- Average propagation speed through soft tissue - Correct Answer 1540m/s 
 
Tissues with greater density (bone) have a higher propagation speed causing structures to appear more - Correct Answer Superficial 
 
Tissues with lesser density (silicone implants) have lower propagation speeds causing structures to appear too - Correct Answer Deep 
 
Artifact caused by a difference in propagation speed causing structures to appear too superficial or deep - Correct Answer Propagation speed error 
 
Optima...
-
$10.49 More Info
Lydiah247
-
Exam (elaborations)
Breast US board review for ARRT (all solved correctly)
-
--10March 20232022/2023A+Available in bundle
- Propagation speed is what in body correct answers 1.54mm/ms or 1540m/s 
 
Name acoustic variables correct answers pressure, density and particle motion 
 
What is the relationship between speed, stiffness, and density? correct answers speed and stiffness do the same thing 
speed and density do different things 
 
What is frequency? correct answers # of cycles per second 
 
How is frequency measured? correct answers Hz 
 
What does frequency affect? correct answers detail and contrast resolution ...
-
$9.99 More Info
SirAnton