- Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about ? On this page you'll find 5 study documents about .

All 5 results

Sort by

ACI Grade 1 Field Testing Certification Practice Test – Irving Questions & Answers
  • ACI Grade 1 Field Testing Certification Practice Test – Irving Questions & Answers

  • Exam (elaborations) • 11 pages • 2025
  • Available in package deal
  • ACI Grade 1 Field Testing Certification Practice Test – Irving Questions & Answers For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) - ANSWERSFalse (2-5 minutes) The temperature measuring device must be accurate to within 0.1 degree. (T or F) - ANSWERS The temperature measuring device shall have a capacity of measuring temperature of freshly mixed conc...
    (0)
  • $7.99
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test - Irving Questions and Answers 100% Solved correctly
  • ACI Grade 1 Field Testing Certification Practice Test - Irving Questions and Answers 100% Solved correctly

  • Exam (elaborations) • 10 pages • 2024
  • ACI Grade 1 Field Testing Certification Practice Test - Irving Questions and Answers 100% Solved correctly It is allowable to remove the temperature measuring devices from the freshly mixed concrete to read the temperature if you cannot see the reading. (T or F) - ANSWER -False The maximum allowable time between obtaining the first and last portions of the composite sample may not exceed 5 minutes. (T or F) - ANSWER -False Start molding specimens for strength tests within 30 minutes after...
    (0)
  • $6.89
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test Questions & Answers 100% Correct.
  • ACI Grade 1 Field Testing Certification Practice Test Questions & Answers 100% Correct.

  • Exam (elaborations) • 7 pages • 2024
  • Available in package deal
  • For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (True or False) - ANSWER False The temperature measuring device must be accurate to within 0.1 degrees. (True or False) - ANSWER False The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of ______ to ______ Fahrenheit ( - ANSWER A composite sa...
    (0)
  • $13.49
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test – Irving 100% Verified.
  • ACI Grade 1 Field Testing Certification Practice Test – Irving 100% Verified.

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) - ANSWER False (2-5 minutes) The temperature measuring device must be accurate to within 0.1 degree. (T or F) - ANSWER The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of _____ to _____ degree F ( ______ to ______ degree C) - ANSWER 3...
    (0)
  • $14.99
  • + learn more