ACI Concrete Field Testing Technician- Grade I Questions and Correct Answers, With Complete Solution 2024/2025. 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. 
3 in. [75 mm] 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. 
1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] 
The tempe...
- Exam (elaborations)
- • 10 pages's •
-
ACI•ACI
Preview 2 out of 10 pages
Getting your document ready...
ACI Concrete Field Testing Technician- Grade I Questions and Correct Answers, With Complete Solution 2024/2025. 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. 
3 in. [75 mm] 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. 
1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] 
The tempe...
ACI Concrete Field Testing Technician Questions and Correct Answers, With Complete Verified Solution 2024/2025. 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. 
3 in. [75 mm] 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. 
1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] 
The tempe...
- Exam (elaborations)
- • 10 pages's •
-
ACI•ACI
Preview 2 out of 10 pages
Getting your document ready...
ACI Concrete Field Testing Technician Questions and Correct Answers, With Complete Verified Solution 2024/2025. 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. 
3 in. [75 mm] 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. 
1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] 
The tempe...
ACI - Concrete Strength Testing Technician (CSTT), Questions and Correct Answers. With Complete Solution. 
 
Standard Practice for Capping Cylindrical Concrete Specimens 
ASTM C617 
Procedures for capping enable concrete cylinders and cores to meet C617's practice requirements for___ and___. 
C617 
perpendicularity, planeness 
 
C617, 3.1 
____ ____ can be made of glass, machined metal, polished granite, or diabase. 
C617
- Exam (elaborations)
- • 13 pages's •
-
ACI•ACI
Preview 2 out of 13 pages
Getting your document ready...
ACI - Concrete Strength Testing Technician (CSTT), Questions and Correct Answers. With Complete Solution. 
 
Standard Practice for Capping Cylindrical Concrete Specimens 
ASTM C617 
Procedures for capping enable concrete cylinders and cores to meet C617's practice requirements for___ and___. 
C617 
perpendicularity, planeness 
 
C617, 3.1 
____ ____ can be made of glass, machined metal, polished granite, or diabase. 
C617