Accurate Real Exam Questions and Verified
Correct Answers
Which of the following decontaminates instruments after an operative procedure?
A. ultrasonic cleaner
B. washer sterilizer
C. glutaraldehyde
D. steam sterilizer - answer>>>A
Which of the following techniques would be BEST to prevent cutting a suture knot when
cutting sutures?
A. angle the tips of the scissors upward
B. cut as far back on the scissor blades as possible
C. turn the suture scissors at an angle
D. use curved scissors to cut the suture - answer>>>C
A patient is experiencing sharp pain the right lower quadrant with nausea and vomiting.
The MOST likely diagnosis is:
A. cholecystitis
B. sigmoid diverticulitis
C. appendicitis
D. intestinal torsion - answer>>>C
The CO2 laser beam is absorbed by:
A. drapes
B. water
C. steel
D. air - answer>>>B
,During an emergency AAA repair, a surgeon performs a laparotomy using which of the
following incisions?
A. upper paramedian
B. upper abdominal transverse
C. long midline
D. subcostal - answer>>>C
How can the surgical technologist provide support to an extremely anxious patient while
waiting for the surgical procedure to begin?
A. explain the steps of the operation in detail
B. ask the anesthesiologist to increase the dosage of the preoperative medication
C. encourage the patient to share her feelings
D. tell the patient there is nothing to fear - answer>>>C
A surgeon has scheduled a patient for a Bilroth I procedure. A surgical technologist should
prepare for which of the following anastomosis?
A. gastrocecal
B. gastrosigmoidal
C. gastroduodenal
D. gastroileal - answer>>>C
After the medication has been distributed, what is the MINIMUM number or times the
strength of the medication must be confirmed before administration to the patient?
A. 1
B. 2
C. 3
D. 4 - answer>>>B
Which of the following cartilages is used as a landmark for making an emergency
tracheotomy?
A. arytenoid
B. cricoid
C. glenoid
,D. thyroid - answer>>>B
A surgical technologist facilitates visualization by retracting tissue during a procedure by
doing which of the following?
A. wait until the surgeon places a retractor and then maintain retractor position
B. anticipate the surgeon's needs and apply an appropriate retractor
C. hold the retractor by toeing the end of the instrument deep into the tissue
D. offer self-retaining retractors and remain available to pass other instruments -
answer>>>A
An O'Sullivan-O'Connor self retaining retractor is specifically designed for a:
A. Pfannenstiel incision
B. lateral incision
C. transverse incision
D. McBurney incision - answer>>>A
The noninvasive manipulation of a fractured extremity followed by application of a splint
or cast is:
A. closed reduction
B. open reduction
C. internal fixation
D. external fixation - answer>>>A
Which of the following hemostatic agents MUST be applied using a dry instrument?
A. Collastat
B. Gelfoam
C. Gelfilm
D. Avitene - answer>>>D
A patient's legs should be uncrossed during surgery to:
A. avoid problems in draping
B. promote optimal exposure of the surgical site
, C. prevent neurovascular compromise
D. facilitate placement of the restraint strap - answer>>>C
Which of the following supplies is part of the standard setup for a cholecystectomy?
A. Pleur-evac
B. GIA stapler
C. #12 blade
D. ligating clips - answer>>>D
A pyloroplasty in gastric surgery is performed to:
A. reconstruct the fundus
B. increase gastric acidity
C. improve gastric drainage
D. tighten the pyloric sphincter - answer>>>D
Which of the following safety precautions MUST be used when transporting a patient on a
stretcher to the operating room?
A. Push the patient head first along the corridors
B. push the patient feet first into an elevator
C. secure the patient's hands to the sides of the stretcher
D. side rails are placed in the up and locked position - answer>>>D
Which of the following is true concerning the sterilization of an implant needed during a
procedure?
A. Bacillus subtillis is the spore used to test the steam sterilizer
B. Bacillus stearothermophilus is the spore used to test the ethylene oxide gas sterilizer
C. Loads containing implantables must be monitored and results known before an implant
is used
D. The EPA requires strict documentation and tracking of implant devices - answer>>>C
The correct procedure for replacing a contaminated glove intraoperatively is to have the
circulator remove the contaminated glove, then:
A. use the open-glove technique to re-glove