Four variables during mechanical ventilation: - Answer: trigger variable- *starts breath*
Control or target variable- mode
Limit variable - maximum value
Cycling variable- *ends inspiration*


What is the primary variable the ventilator adjusts to achieve inspiration - Answer:
control or target variable
Volume control or target- set volume to be delivered
Pressure control or target- set pressure to be delivered


Limit variable: - Answer: establishes a maximum value that a variable (pressure,
volume, time, flow) can reach during inspiration


Cycling variable: - Answer: the variable that ends (terminates) the inspiratory phase of
a positive pressure breath


Spontaneous breath - Answer: patient controls all variables pertaining to each breath


Mandatory breath - Answer: ventilator controls all variables pertaining to the breath


Assisted breath - Answer: patient initiates the breath and the ventilator controls the
remaining variables


High pressure alarm - Answer: should be set at 10 cmh2o above peak airway pressure


Minimum exhaled volume alarm - Answer: should be set 100 ml below exhaled tidal
volume


Low pressure alarm - Answer: set 10 cmh20 below peak airway pressure

1
APPHIA - Crafted with Care and Precision for Academic Excellence.

,Oxygen alarm - Answer: set 5% below & above set fio2


Three phases to mechanical ventilation: - Answer: phase 1- initial setting
Phase 2- monitoring/manipulating
Phase 3- weaning


Ventilator failure to cycle, loss of power, oxygen failure - Answer: check power supply


Inline MDI should be located on the vent? - Answer: on inspiratory side of the Y-
adaptor, as close to pt as possible


Troubleshooting ventilator always - Answer: provide manual ventilation first


Low pressure alarm consider - Answer: - pt disconnect
- leak in circuit
- insufficient flow
- endotracheal/tracheostomy tube cuff leak


High pressure alarm consider - Answer: - obstruction (ETT, pneumothorax, raw,
secretions, etc)
- equipment obstruction (vent circuit)


Low exhaled volume alarm - Answer: - disconnect (vent circuit)
- low spontaneous VT


A pt who is being mech vent has received an MDI tx inline with vent circuit. Following tx
the low exhaled Vt alarm is sounding. Why would this occur & how should it be fix? -
Answer: most likely caused by leak in system causing loss volume.
Correct inspect circuit for loose connections



2
APPHIA - Crafted with Care and Precision for Academic Excellence.

, QC procedure for ventilator the accuracy controlled by the vent should be verified
periodically: variable- volume pressure flow - Answer: volume - spirometer
Pressure - mercury or water manometer
Flow - rotameter


Phase 1: initial settings - Answer: recommend/initiate mechanical ventilation
Recommend/select initial ventilator settings


Phase 2: monitoring/manipulating settings - Answer: monitor the pt, recommend/initiate
changes to vent settings, identify and correct problems with the patient and vent


Phase 3: weaning - Answer: assess the pt readiness for weaning, implement weaning
procedures, monitor the pt during weaning


Indications for continuous mechanical ventilation: - Answer: 1. Apnea- not breathing
(observation) absolute indication


2. Acute ventilatory failure/acute respiratory failure- insufficient spontaneous ventilation
to maintain normal physiologic parameters, including paco2 and pao2


3. Impending ventilatory failure- trend of rising paco2 and/or decreasing Vt, VC, MIP


4. Oxygenation- to reduce WOB (if pt has acceptable paco2, O2 can be fixed with
oxygen therapy


Initiating MV according to patient assessment: - Answer: 1. ABG
2. Bedside ventilatory parameters
3. Physiological assessment/calculations


Bedside ventilatory parameters:
Normals and unacceptables:

3
APPHIA - Crafted with Care and Precision for Academic Excellence.

Written for

Institution
Mechanical
Course
Mechanical

Document information

Uploaded on
December 16, 2025
Number of pages
17
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
Apphia
5.0
(1)

Get to know the seller

Seller avatar
Apphia California University Of Pennsylvania
View profile
Follow You need to be logged in order to follow users or courses
Sold
2
Member since
5 months
Number of followers
0
Documents
2133
Last sold
4 weeks ago
Apphia Tutors - Your Ultimate Study Companion for Academic Excellence.

Apphia Tutors is your all-in-one global study guide hub — built to make learning simple, smart, and rewarding. We bring together thousands of high-quality study materials, topic-specific notes, and verified answers designed to help students master every subject with ease. Whether you’re in high school, college, or university, Apphia Tutors has everything you need — from clear explanations to exam-ready practice questions. Our goal is to turn studying into a confident, stress-free journey toward success. Trusted by learners and educators worldwide, Apphia Tutors is where great grades begin and excellence grows.

Read more Read less
5.0

1 reviews

5
1
4
0
3
0
2
0
1
0

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions