Questions With Accurate Solutions
Save
Terms in this set (47)
A special inspector shell demonstrate competence to
Building official
the satisfaction of the
The special inspector observes critical building or
structural elements identified in the statement of special
Plans and specifications
inspections for compliance with...and...approved by the
building official
All non-conforming items shall be brought to the
Contractor
immediate attention of the
Owner or owners Who can employ an improved inspection agency?
authorized agent
Special inspections are in addition to the...performed by
Jurisdiction, structural
the city inspectors and the... performed by the structural
observation
engineer of record.
Special inspections review the...while jurisdictional
Find details, brighter details
inspections review the...
Register design When non-conforming items are not corrected the
professional and building special inspector shall notify the
official
Register design The permit applicant shall submit a statement of special
professional inspections prepared by the
Building official register Who shall the special inspector furnish inspection
design professional and reports/progress reports to?
other designated people
Registered design Who performs a structural observation?
professional
Is the full-time observation of work requiring special
Continuous inspection
inspection
, Is special inspection required for concrete placement of
No 1705.3 exception 1 IBC 3000 PSI concrete in isolated spread footings for a
single story warehouse?
Special inspection by the special inspector who is
Periodic special inspection intermittently present where the work to be inspected
has been or is being performed.
Is special inspection required for concrete placement of
continuous footings, for poured in-place walls, if the
Yes 1705.3 IBC building is two stories in height and the engineer
includes all footings in his statement for special
inspection?
If it takes 6 1/2 hours to pour 4 sheer walls and 26
As long as it takes. Table columns on the third level of a 10 story building, how
1705.3 much time is the special inspector required to be on
site?
Temperature, air content, What other tests are required every time strength test
and slump are cast?
Statement of special Where does it specify the types and extent of special
inspection 1704.3.1 IBC inspection required?
Structural observation is required for all buildings
75 feet 1704.6.1 IBC over...in height for building located in seismic design
category D
Building official 1704.2 Who can waive the requirement of special inspections
exception 1 on work of minor nature?
Verified with periodic The inspections of curing temperatures and techniques
special inspection table for concrete should be...
1705.3 IBC
The statement of special The type and extent of each special inspection shall be
inspection located in
Who has the legal authority to enforce the special
Building official
inspection provisions of the building codes?
Owners agent Who can hire an improved inspection agency?
Registered design Who can perform a structural observation?
professional
Building department Who is required to receive the final report?