IRC TEST NEWEST 2025 ACTUAL EXAM
COMPLETE 200 QUESTIONS AND CORRECT
DETAILED ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+||BRAND NEW!!
Sump pumps shall be permitted in an elevator shafts
provided that they are
____________ ___________ to the plumbing system. -
.....ANSWER ...✔✔ Indirectly connected
IPC 301.6 exception
What type of water heaters are permitted in bedrooms
? - .....ANSWER ...✔✔ Direct vent water heaters
IFGC 303.3
The international residential code is applicable to
plumbing work in townhouses not more
than______________in height with a separate means of
egress - .....ANSWER ...✔✔ Three stories
,2|Page
The provisions of the appendices do not apply
unless____________. - .....ANSWER ...✔✔
Specifically adopted
In order to safeguard life, health and property, the IPC
regulates all of the following within the building
environment, except_____________. - .....ANSWER
...✔✔ Cost
Where different sections of the code specify different
requirements, the_____________requirement shall
apply. - .....ANSWER ...✔✔ Most restrictive
Existing plumbing systems must be brought into
compliance with the IPC if the system
is______________. - .....ANSWER ...✔✔ A hazard to
property
Where code provisions are in conflict with the
referenced standard,The_____________provisions shall
apply. - .....ANSWER ...✔✔ Code
Where the code official fins that a proposed alternative
material does not comply with the intent of the code
provisions, the code official shall_____________. -
,3|Page
.....ANSWER ...✔✔ State the reason for disapproval
in writing to the applicant
For materials not specifically covered by the code,
supporting data necessary to verify compliance with the
code must include______________. - .....ANSWER
...✔✔ Research report
Tests performed by______________may be required
by the code official where there is insufficient evidence
of the code. - .....ANSWER ...✔✔ An approve agency
Required department records shall be
retained______________. - .....ANSWER ...✔✔ As
required by public records
The code official shall be appointed by
the_____________. - .....ANSWER ...✔✔ Chief
appointing authority
The prescribed portions of standards referenced in the
IPC and listed in chapter 15 are
considered______________. - .....ANSWER ...✔✔
Requirements
, 4|Page
The code official shall require construction documents
and specifications to be prepared by registered design
professional when_______________. - .....ANSWER
...✔✔ Required by state law
Which of the following information is not specifically
required on the permit application? - .....ANSWER
...✔✔ Type of construction
Who is responsible for inspection scheduling? -
.....ANSWER ...✔✔ The permit holder
A permit is not required for________________. -
.....ANSWER ...✔✔ Repairing of leaks in pipes, valves
or fixtures
Permits expire if work is not commenced
within___________days of issuance. - .....ANSWER
...✔✔ 180
An application for an appeal of the code officials
decision must be filed within______________days after
receipt of the notice. - .....ANSWER ...✔✔ 20