What is the specific weight of water? - Correct answer-62.4 lbs per cubic foot

What happens in a storm and sanitary system after it passes the water test? -

Correct answer-A smoke pressure test is recommended with a smoke pressure of 1

in wc to prove the system gas tight.

Is an air test acceptable for a storm and sanitary system? - Correct answer-Yes, if a

water test is not possible, at a pressure of 5 psi, are tests are impractical and costly

What are the testing procedures for the storm and sanitary system? - Correct

answer-A water test upon completion of the rough piping and prior to concealment

of 10 ft wc minimum (except the topmost 10 feet of pipe), not to exceed 100 ft wc.

If system is higher than 100 feet, test plugs must be installed to facilitate testing,

rarely are more than 7 stories tested at one time. A peppermint oil test may also be

done with 2 oz of peppermint oil and 10 qt boiling water, and searching for




©COPYRIGHT 2025, ALL RIGHTS RESERVED 1

,peppermint smell at leaks, however it is difficult to pinpoint the leak by this

method

The maximum length from the vent connection to any future drain outlet is

required by code, why, how long is the distance (listed in the book), and what’s

the exception? - Correct answer-To prevent a dead end where slime, sludge and

fungi can grow, 2 feet, unless the piping must be extended to an accessible location

for a cleanout

A sanitary tee may be used in the vertical but what may not be used in the vertical

and why? - Correct answer-A double sanitary tee because the possibility of flow

crossover and excessive pressures when one branch is discharging and the other

isn’t are possible

What are the slopes of pipe inside the building that correspond to 2 fps velocity? -

Correct answer-1/4 in per foot for 3 in and smaller 1/8 in per foot for larger pipe all

elbows, taps, tees etc are tapped at a pitch of 1/4” per foot

Where should cleanouts be provided? - Correct answer-1) Inside or outside the

building at the point of exit (use a wye branch) 2) at every change in direction

greater than 45 degrees 3) every 50 feet for piping 4” and less, and 100 ft for

larger piping 4) underground piping larger than 10 in should be provided with



©COPYRIGHT 2025, ALL RIGHTS RESERVED 2

,manholes at every change in direction and every 150 feet 5) at the base of all

stacks 6) as required by code

What size cleanouts are provided in piping? - Correct answer-Piping up to 4

inches, the cleanout is the same size as the pipe. Piping greater than 4 inches, 4

inch cleanouts are adequate.

What should be installed in the house drain if there is a danger of backflow of

sewage into the building? Whats the difference? - Correct answer-A backwater

valve or a combination BWV with manually operated gate valve. The BWV does

not interfere with the airflow throughout the system, and the gate valve is

recommended where there is a history of backflow as a positive means of

protection.

Branch connections to the house drain should be made where and why? - Correct

answer-At the upper portion of the pipe (above the 1/2 - 2/3 full mark) because: 1)

there is a lower chance of stoppages in the branch 2) there is less flow interference

at the point of connection 3) When there is no flow in the branch, the full area of

the pipe is available to relieve pneumatic pressure fluctuations in the house drain

How many fixture units are equivalent to 1 gpm continuous or semicontinuous

flow and what are examples of these types of flow? - Correct answer-2 FUs, sump

pumps, ejectors, air conditioning equipment, water cooled, equipment, etc

©COPYRIGHT 2025, ALL RIGHTS RESERVED 3

, What minimum slopes are required for building drains and why? - Correct answer-

3 in pipe and smaller: 1/4 in/ft 4-6 in pipe: 1/8 in/ft 8 in pipe and larger: 1/16 in/ft

to maintain 2 fps scouring action if low flow fixtures are present, 1/4 in/ft for all is

a good idea

House drains are designed to flow how full? - Correct answer-1/2 full to 3/4 full

max under uniform flow conditions

What is a house (building) drain? - Correct answer-The lowest piping of a gravity

drainage system that receives the discharge from soil, waste, and other drainage

pipes inside the building that extends a short distance from the building and

conveys the drainage to the building sewer

What is the measurement from horizontal that separates horizontal and vertical

drainage stacks? - Correct answer-45 degrees

Does an interior drainage stack that offsets 45 degrees or less from the vertical

require a change in size? - Correct answer-No. Any more than a 45 degree offset

requires sizing the offset as a house drain.

What is a branch interval? - Correct answer-A building story or a distance between

two branch connections greater than 8 feet apart.




©COPYRIGHT 2025, ALL RIGHTS RESERVED 4
$13.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
EmmaGrants

Also available in package deal

Thumbnail
Package deal
AHS 180 Bundled Tests Questions and Answers Graded A+
-
12 2025
$ 146.88 More info

Get to know the seller

Seller avatar
EmmaGrants Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
New on Stuvia
Member since
2 months
Number of followers
0
Documents
964
Last sold
-
Howard Community College Study Hub.

Welcome to HCC Study Hub, your go-to place for top-quality study materials from Howard Community College. Whether you're prepping for exams or just consolidating your notes, you'll find: -Lecture notes from past courses -Practice exams with detailed answers -Comprehensive study guides -Package deals for full semester bundles All documents are carefully reviewed, accurate, and designed to help you succeed. Uploads are updated regularly based on the latest course syllabi. Happy studying — and good luck!

Read more Read less
0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions