100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

NEC Journeyman Test Practice Questions and Correct Answers/ Latest Update / Already Graded

Rating
-
Sold
-
Pages
41
Grade
A+
Uploaded on
30-11-2025
Written in
2025/2026

NEC Journeyman Test Practice Questions and Correct Answers/ Latest Update / Already Graded

Institution
NEC - Journeyman
Course
NEC - Journeyman











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NEC - Journeyman
Course
NEC - Journeyman

Document information

Uploaded on
November 30, 2025
Number of pages
41
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Page |1


NEC Journeyman Test Practice Questions
and Correct Answers/ Latest Update /
Already Graded
Devices __ for bonding the metallic frames of PV modules shall be
permitted to bond the exposed metallic frames of PV modules to the
metallic frames of adjacent PV modules.

Ans: 690.43(B) All of these: Listed, Labled, Identified,


Where exposed and subject to physical damage, PV array equipment
grounding conductors smaller than 4 AWG shall be protected by a
raceway or cable armor.

Ans: 250.120 (C) FALSE


Buildings/structures containing both utility service and a PV system
shall have a ________installed in accordance with 705.10.

Ans: 690.56 (B) Plaque, OR Directory


A(n) __ surge protection device shall be installed in or on the fire pump
controller.

Ans: 695.15 Listed




All rights reserved © 2025/ 2026 |

, Page |2

Emergency system equipment shall be maintained in accordance with
______.

Ans: Manufacturer's instructions AND Industry standards


Where used for emergency systems, the short-circuit current rating of
the transfer equipment, based on the specific overcurrent protective
device type and settings protecting the transfer equipment, shall be
field marked on the ______of the transfer equipment.

Ans: 700.5 (E) exterior


Emergency circuits shall be permanently marked so they will be readily
identified as a component of an emergency circuit or system and __
____.

Ans: 700.10 (A)(1)(2) All boxes and enclosures (Including
transfer switches, generators and power panel) or emergency
circuits shall be permanently marked as a component of an
emergency circuit or system AND where boxes or enclosures are
not encountered exposed cable or raceway systems shall be
permanently marked to be identified as a component of an
emergency circuit or system and intervals not to exceed 25 FT


Emergency circuits shall be permanently marked so they will be readily
identified as a component of an emergency circuit or system and
receptacles supplied from the emergency system shall have a(n)

All rights reserved © 2025/ 2026 |

, Page |3

_______ color or marking on the receptacle cover plates or the
receptacles.

Ans: 700.10(A) Distinctive


If wiring from an emergency source is used to supply emergency and
other loads, then ________ switchgear sections or switchboard
sections, with or without a common bus, or individual disconnects
mounted in separate enclosures shall be used to separate emergency
loads from all other loads.

Ans: 700.10(B)(5)(A) Separate Vertical


Wiring from an emergency source to supply emergency and other
(nonemergency) loads shall be permitted if the common bus of
separate sections of the switchgear, separate sections of the
switchboard, or the individual enclosures are supplied by single or
multiple feeders ______.

Ans: 700.10(B)(5) I AND II Without overcurrent protection at
the source AND With overcurrent protection, provided that the
overcurrent that is common to the emergency system and any
non-emergency system(s) is selectively coordinated with the
next downstream overcurrent protection device in the non -
emergency system(s)




All rights reserved © 2025/ 2026 |

, Page |4

Batteries for unit equipment for emergency systems shall be of
suitable rating and capacity to supply and maintain the total lamp load
associated with the unit for a period of at least _____ hour(s) without
the voltage falling below 87½ percent of normal battery voltage.

Ans: 700.12(C) 1 1/2


Batteries for unit equipment for emergency systems shall be of
suitable rating and capacity to supply and maintain the total lamp load
associated with the unit and the unit equipment shall supply and
maintain not less than __ percent of the initial emergency illumination
for a period of at least 1½ hours.

Ans: 700.12(I)(2)(1)(B)


A written record shall be kept of required tests and maintenance on
legally required standby systems.

Ans: 701.3(D) True


The branch-circuit overcurrent devices for legally required standby
systems shall be accessible only to ______.

Ans: 701.30 Authorized Persons




All rights reserved © 2025/ 2026 |

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Expert1 Chamberlian School of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
41
Member since
11 months
Number of followers
1
Documents
7239
Last sold
2 days ago
Expert1

Welcome to Expert1 – Your Trusted Study Partner! Struggling to prepare for exams or ace your coursework? At Expert1, I provide top-tier, exam-ready study materials designed to help you succeed with confidence. All notes are created with clarity, precision, and a deep understanding of the curriculum to ensure you save time and score high. What You’ll Find Here: High-quality summaries and exam packs Past paper solutions with detailed explanations Notes aligned with your syllabus (A-levels, university, etc.) Resources from top-performing students Trusted by hundreds of students to boost their grades!

Read more Read less
4.3

6 reviews

5
5
4
0
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions